Terra Universal - Critical Environment Solutions

Preferred Client

Clean Room Fire Safety Solutions: Detection and Suppression Systems

Effective fire detection requires careful placement of sensors capable of detecting all kinds of fires, large and small, often in the presence of chemical vapors that restrict visibility. This is exactly the capability provided by the FS System 7 Fire Detection System listed below.

CO2 or Water Suppression?

The FS System 7 is ideal for semiconductor wet bench applications, as well as pharmaceutical or chemical mixing operations involving flammable materials.

In these applications, a CO2-based fire suppression system can be integrated with FS System 7 to ensure that any fire that exceeds the critical 14 kW energy level is promptly extinguished. The dual-level response of this system provides an opportunity for very small (4kW - 13kW) fires to self-extinguish before a fire suppression system is activated. In wet benches and mixing stations, CO2 nozzles can be installed so that their discharge affects only fire-likely locations.

Whatever your applications, Terra engineers will work with you to determine the fire suppression system most appropriate to your requirements, as well as to local fire codes.

Fire Suppression Water Sprinkler

Installed at user-selected overhead locations. Includes heat sensor and all necessary plumbing and operation controls.
Cat. # $/Each
Sprinkler Head 6600-90 Login
Water Line
(price is per linear foot)
6600-91 Login

Fire Detection System Function
 
Cat. # $/Each
Dual-Spectrum IR Sensor
Several typically required, depending on application
6704-26 Login
PLC Controller
Includes warning light/alarm and fire siren
6704-25 Login
Uninterrupted Power Supply
Ensures system operation in the event of power failure
6705-05 Login
 

FS System 7 Fire Detection System

  • The ideal monitoring system for wet benches, exhaust fume lines, and other potentially hazardous cleanroom equipment involving volatile chemicals
  • Multi-spectral IR flame detector senses all types of fires, even through gases and vapors
  • Electro-optical sensor design meets Factory Mutual (FM) requirements
  • Sensor range of 120° within 8 feet allows a pair of sensors to monitor most cleanroom processes thoroughly
  • PLC module includes warning light and alarm, fire siren, and low-voltage output to activate fire suppression system (order separately)
  • Unique FirePic™ software stores the pre-fire and actual fire detector-sensor spectral data from the last six fire events in nonvolatile memory for subsequent analysis

The FS System 7 electro-optical fire detectors provide an intelligent, two-stage response to fires. This allows time for the fire to self-extinguish, thereby averting equipment shutdown and the costly destruction of work in process. This two-stage response alerts that a fire exists, provides fast detection response should the fire not self-extinguish, and initiates suppression, if necessary.

Unique Two-Stage Fire Response

ALERT-1™: This first-stage response triggers external audible and visual signals when a fire with a heat energy output of 3 kW (the equivalent of a 4-inch diameter polypropylene pool fire) is exceeded. These alarms alert the operator that a fire exists before suppression begins, but gives non-hazardous fires time to self-extinguish before invasive fire suppression is activated. The FS System 7 fire detector will record a time- and date-stamped FirePic™ digital fire signature. This numerical spectral evidence enables analysis of the probable cause of the fire event for use in preventing a subsequent, damaging fire.

ALARM-2™: If the fire does not self-extinguish, and grows to the second-level heat energy threshold of 13 kW (the equivalent of an 8-inch diameter polypropylene pool fire), this second-stage response signals suppression release. In applications with wet benches, electrical power is shut down. In systems that incorporate electronic CO2 extinguishers, a low-voltage signal activates fire suppression. A FirePic™ is again recorded to provide information for use in analyzing the cause of the fire.

The fire detectors are digital, 100% solid-state with quantum electro-optical multi-spectral Wide Band IR (1.2 - 3.5 micron band width), Near Band IR (.7 - 1.1 micron band width), and Visible Band sensor array, (0.4 ­ 3.5 micron band width). This broad bandwidth sensitivity allows it to detect all hydrocarbon and non-hydrocarbon fires, even through the gases and vapors found in chemical wet benches. Detectors are housed in a heat-sealed, Clean Room Class-1 rated polypropylene material to protect against acids or caustics. It requires no field calibration or other maintenance. Sensor Dimensions: 4.7" x 3.2" x 1.7"

Fire Detection System

FirePic™ software provides digital spectral data that enables analysis of the probable cause of a fire. It will store 6 fire events in non-volatile digital memory, 8 seconds of pre-fire, actual detector sensor spectral data, and time and date for each event. The stored data include a graphical display of the relative spectral intensities versus time preceding and during the fire. All data can be downloaded to PC via RS-232 serial port.

All part numbers below include installation. Call Terra for assistance in configuring the F7 Fire Detection System.

Solutions by Industry
Builders(AEC) | Pharmacies
Forensic Labs | Animal Labs
Request A Quote
Submit Your RFQ Online
Submit Your RFQ Online
Log in and click any price to add an item to your Quote Cart.
 
QuickQuote Planner
Online Configuration
Online Configuration
QuickQuotes help you specify select systems to your requirements.
 
Need It Right Away?
Blue Prices Indicate QuickShip Items
Blue Prices Indicate QuickShip Items
These ship within a week, usually the very next day. Call for available quantity.
 