A. Glove Port     B. Port Cover     C. Iris Adapter  
glove port glove ports glove port port cover glove port glove ports
10" (254mm)-diameter port is standard on all Terra gloveboxes. Order covers and iris adapter separately.
Complete Information
  Cat. # $/Each
A. Replacement Glove Port 1694-52 Login
B. Port Cover 1694-53 Login
C. Iris Port 1694-54 Login


RH/Temperature Data Logger
RH/Temperature Data Logger
Provides a convenient record of storage conditions! Placed in a desiccator or glovebox, this compact device accumulates humidity and temperature data at specified intervals for hours, days, weeks, even months. USB connection lets you import and display data in several formats.
Cat. # $/Each
9500-10 Login

glove box Tilt-Up Viewing Window Tilt-Up Viewing Window
Swings open for easy access. Dual piston mechanisms hold the window securely open. Price includes modification of Series 100 glove box to include hinged viewing window. Must be ordered together with affected glove box. Viewing window has a 304 stainless steel frame.
For Series 100 Gloveboxes
Static Dissipative PVC Cat. #
$/Each

With Stainless Steel Frame
For single chamber
29"W x 11"H
737 mm x 279 mm
3305-20 Login
For twin chamber
53"W x 11"H
1346 mm x 279 mm
3305-21 Login
With Powder-coat Frame
For single chamber
29"W x 11"H
737 mm x 279 mm
3305-22 Login
For twin chamber
53"W x 11"H
1346 mm x 279 mm
3305-23 Login

glovebox Swing-Up Front Access Panel Swing-Up Front Access Panel
Allows convenient introduction of large parts into the processing chamber. Cutout size: 20"W x 10"H (508 mm x 254 mm), other sizes available; specify when ordering. Must be ordered together with affected glove box (Series 100 or 200).
  Cat. # $/Each
Acrylic* 1685-85 Login
Polycarbonate 1685-86 Login
Static Dissipative PVC 1685-87 Login
Nondissipative PVC 1685-88 Login
*Acrylic is damaged by alcohol and other cleaning agents.

Detachable Bottom
Detachable Bottom
This feature allows the glove box to be detached from its bottom and lifted for easy placement over large equipment. The bottom attaches and seals to the glove box by means of dual-gasketed latches located along the base.
Cat. # $/Each
1681-55 Login

glovebox Bellows Eyepiece Interface
Bellows Eyepiece Interface
This cutout is sealed with a bellow-type diaphragm to allow viewing of a stereo microscope positioned inside any of Terra's stainless steel glove boxes. Standard cutout size is 8"W x 6"H (203 mm x 152 mm). Specify desired location or custom size when ordering.
Cat. # $/Each
1681-53 Login

Glove Box Dual Purge System
Glove Box Dual Purge System
Provides variable-flow purge control to save nitrogen expenses.
  Cat. # $/Each
NitroWatch Controller 9500-00A Login
NitroWatch Sensor 9500-02A Login
Works in tandem with the Dual Purge System to maintain the selected relative humidity level.

bleed relief valve Automatic RB® (Relief/Bleed) Valve
Safeguards glove box against overpressures. Required for operation with Dual Purge System.
Cat. # $/Each
1600-60A Login

relief bleed valve Automatic RB Valve (for use with caustinc materials)
Terra's stainless steel Automatic RB® Valve is designed for use with caustic gas. It incorporates a Teflon® valve mechanism.
Cat. # $/Each
1600-60 Login

Dryex® Gas Dryer Dryex® Gas Dryer
Removes moisture and particulates from compressed air feed.
Cat. # $/Each
9082-00 Login

nitrogen generator Nitrogen Generator
Semiporous micromembrane technology yields 99.9% pure nitrogen to ensure an economical, reliable, uninterrupted gas source
Cat. # $/Each
2700-09A Login

ionizing blower Ionizing Blower
Provides safe, effective static neutralization inside a glove box or similar enclosure. Designed for overhead chamber mounting, it generates a balanced stream of positive and negative ions to neutralize surface static charges, safeguarding ESD-sensitive materials. Includes fans for even distribution.
Glove Box IonBar™ (installed)

 

110VAC, 50/60Hz 220VAC, 50Hz
Cat. # $/Each Cat. # $/Each
22"L (559 mm)
with 4 emitters
2005-30 Login
2005-30-220 Login
33"L (838 mm)
with 6 emitters
2005-32 Login
2005-32-220 Login
44"L (1118 mm)
with 8 emitters
2005-31 Login
2005-31-220 Login

Filtration Modules Filtration Modules
These modules allow continuous recirculation of process gas through a HEPA or ULPA filter to remove particles, aerosols, microbes, chemical powders, and other fine contaminants. A variety of open/closed-loop configurations allow 100% exhaust, 100% recirculation, or a mixture of filtered and fresh make-up air.

Universal Filter/Blower Universal Filter/Blower
This positive pressure system, designed for use on Series 100 Glove Boxes, directs a flow of particle-free air into the glove box. Select HEPA or ULPA filter. Note: Gloves must be removed to allow air to escape the enclosure.
  Cat. # $/Each
Blower (740 CFM, 1258 m³/hr, stainless steel) 110V 1685-97 Login
Blower (740 CFM, 1258 m³/hr, stainless steel) 220V 1685-97-220 Login
Filter Housing (stainless steel) 1685-98 Login
HEPA Filter 1681-02 Login
ULPA Filter 1681-10 Login

Magnehelic Gauges Magnehelic Gauges
This MAGNEHELIC®Principle is a method of transmitting the effects of changes in air pressure from a diaphragm to an indicating pointer—by means of magnetic linkage and without the use of gears or other direct mechanical linkages. This system avoids wear and physical contact, which might destroy the accuracy and sensitivity of the instrument. It delivers accuracy to within 2% of full scale. Complete information.
MAGNEHELIC® Gauges
Pressure Range
(inches WC)
Weight Uninstalled Installed
Cat. # $/Each Cat. # $/Each
0-0.5 1 lb. 2 ozs.
510 g
2625-08 Login
2625-30 Login
0-1.0 1 lb. 2 ozs.
510 g
2625-09 Login
2625-31 Login
0-2.0 1 lb. 2 ozs
510 g
2625-10 Login
2625-32 Login
0-3.0 1 lb. 2 ozs.
510 g
2625-11 Login
2625-33 Login
0-4.0 1 lb. 2 ozs.
510 g
2625-12 Login
2625-34 Login
.25-0-.25 1 lb. 2 ozs.
510 g
6600-86 Login

PHOTOHELIC® Pressure Control PHOTOHELIC® Pressure Control
PHOTOHELIC® models combine the MAGNEHELIC® gauge with a precise pressure switch that lets you control low and high gas pressures. Knob controls adjust dual set points, which allow for variable deadband control. These set points contain photocells that actuate DPDT relays when room pressures reach a preset upper or lower limit, and they can be set up to control corrective damper action. As the room pressure changes in response to damper motion, and the indicator returns to the null band, damper motion is halted. Complete information.
PHOTOHELIC® Gauges
Pressure Range
(inches WC)
Weight
lbs. (g)
Uninstalled Installed
Cat. # $/Each Cat. # $/Each
0-0.5 4
(1814)
2625-13 Login
2625-35 Login
0-1.0 4
(1814)
2625-14 Login
2625-36 Login
0-2.0 4
(1814)
2625-15 Login
2625-37 Login
0-3.0 4
(1814)
2625-16 Login
2625-38 Login
0-4.0 4
(1814)
2625-17 Login
2625-39 Login
.25-0-.25 4
(1814)
6600-87 Login

Minihelic II® Differential Pressure Gauges Minihelic II® Differential Pressure Gauges
Combining clean design, small size and low cost with enough accuracy for all but the most demanding applications our Minihelic®II gauge offers the latest in design features for a dial type differential pressure gauge. Complete information.
Minihelic II® Gauges
Pressure Range
(inches WC)
Weight
ozs. (g)
Uninstalled Installed
Cat. # $/Each Cat. # $/Each
0-0.5 6
(170)
2625-43 Login
2625-48 Login
0-1.0 6
(170)
2625-44 Login
2625-49 Login
0-2.0 6
(170)
2625-45 Login
2625-50 Login
0-3.0 6
(170)
2625-46 Login
2625-51 Login
0-5.0 6
(170)
2625-47 Login
2625-52 Login

DIGIHELIC® Differential Pressure Controller DIGIHELIC® Differential Pressure Controller
Allows the selection of pressure, velocity or volumetric flow operation. Two SPDT control relays with adjustable dead bands are provided, with scalable 4-20mA process output. Complete information.
DIGIHELIC® Differential Pressure Gauge
Pressure Range
(inches WC)
Weight
lbs. (g)
Uninstalled Installed
Cat. #
$/Each**
Cat. #
$/Each**
0 – 1.0 14
(6350)
2625-26 Login
2625-40 Login
0 – 5.0 14
(6350)
2625-27 Login
2625-41 Login
1.0 – 0 – 1.0* 14
(6350)
2625-28 Login
2625-42 Login
*Bi-Direction Range. Velocity and volumetric flow not available on bi-directional unit.
**Price includes installation
Click to leave a message. 24-hour sales and tech phone support, M - F
Technical Questions?
Schedule a call with a
Terra tech specialist.

Terra University

Discount Inventory

Mobile Site