Preferred Client

Options Check List for Stainless Steel Gloveboxes


A. Glove Port     B. Port Cover     C. Iris Adapter  
glove port glove ports glove port port cover glove port glove ports
10"-diameter port is standard on all Terra gloveboxes. Order covers and iris adapter separately.
Complete Information
  Cat. # $/Each
A. Replacement Glove Port 1694-52 Login
B. Port Cover 1694-53 Login
C. Iris Port 1694-54 Login

RH/Temperature Data Logger
RH/Temperature Data Logger
Provides a convenient record of storage conditions! Placed in a desiccator or glovebox, this compact device accumulates humidity and temperature data at specified intervals for hours, days, weeks, even months. USB connection lets you import and display data in several formats.
Cat. # $/Each
9500-10 Login

Tilt-Up Viewing Window Tilt-Up Viewing Window
Swings open for easy access. Dual piston mechanisms hold the window securely open. Price includes modification of Series 300 or 400 stainless steel glove box to include hinged viewing window. Must be ordered together with affected glove box. Dimensions given are for cut-out. Viewing Window has a 304 stainless steel frame.
Cat. # $/Each
For single chamber
(28.25"W x 12.75"H)
1684-92 Login
For twin chamber
(52.625"W x 12.75"H)
1684-93 Login

Disposal Trap Door Disposal Trap Door
Hinged door can be installed on any stainless steel glove box to allow easy disposal of waste or introduction/removal or small parts. Chrome-plated latch is easy to engage and forms an airtight seal. Standard location is next to air lock. Dimensions: 8" x 12"
Cat. # $/Each
1694-41 Login

Sloping Bottom with Drainage Valve Sloping Bottom with Drainage Valve
Ideal for solvent cleaning and other chemical processing. A platform (either perforated stainless steel or wire grid) provides a level work surface. Chemical spills drain to a reservoir with a convenient drain valve (specify stainless steel, PTFE, polypropylene, or other valve material).
Cat. # $/Each
1694-42 call TUI

Detachable Bottom Detachable Bottom
Removable bottom panel allows Series 500 glove box to be lifted for easy placement over large equipment. Attaches and seals by means of two clamps.
Cat. # $/Each
48"W Box 1702-50 Login
96"W Box 1702-51 Login

Bellows Eyepiece Interface Bellows Eyepiece Interface
This cutout is sealed with a bellow-type diaphragm to allow viewing of a stereo microscope positioned inside any of Terra' s stainless steel glove boxes. Standard cutout size is 8"W x 6"H. Specify desired location or custom size when ordering.
Cat. # $/Each
1681-53 Login

Glove Box Dual Purge™ System Glove Box Dual Purge™ System
Provides variable-flow purge control to save nitrogen expenses.
Cat. # $/Each
NitroWatch Controller 9500-00A Login
NitroWatch Sensor 9500-02A Login
Works in tandem with the Dual Purge System to maintain the selected relative humidity level.
Works in tandem with the Dual Purge™ System
to maintain the selected relative humidity level.

relief bleed valve Stainless Steel Automatic RB® (Relief/Bleed) Valve
Safeguards glove box against overpressures. Required for operation with Dual Purge™ System.
Cat. # $/Each
1606-60 Login

Gas Mixer Gas Mixer
Allows precise mixtures of process gases, such as He/N2 or He/Ar used in package seam welding.
Cat. # $/Each
2701-00 Login

Dryex™ Gas Dryer Dryex™ Gas Dryer
Removes moisture and particulates from compressed air feed.
Cat. # $/Each
9082-00 Login

 


Nitrogen Generator Nitrogen Generator
Semiporous micromembrane technology yields 99.9% pure nitrogen to ensure an economical, reliable, uninterrupted gas source.
Cat. # $/Each
2700-09A Login

Humex™ Humidifier Humex™ Humidifier
Humidifies glove box from ambient to 100% RH.
Cat. # $/Each
9081-00 Login

Process Gas Heater Process Gas Heater
Heats process gas up to 350°F for high-temperature testing.
Cat. # $/Each
4320-00 Login

Process Gas Cooler Process Gas Cooler
An economical way to cool process gas 20°F below ambient, down to 40°F.
Cat. # $/Each
9450-00 Login

Constant Temperature Control System Constant Temperature Control System
This constant temperature control system features heater and refrigeration modules working together to maintain a specific temperature in a glove box. Complete information.
Temperature
Range
Compressor Size BTU/Hour
Capacity
110 VAC, 50/60Hz 220 VAC, 50/60Hz
Cat. # $/Each Cat. # $/Each
-10º to 120ºF 0.5HP 3800 1694-76 Login
1694-76-220 Login
-25º to 120ºF 0.75HP 5900 1694-78 Login
1694-78-220 Login
5º to 120ºF 0.5HP 3800 1694-75 Login
1694-75-220 Login
5º to 120ºF 0.75HP 5900 1694-77 Login
1694-77-220 Login

Ionizing Blower Ionizing Blower
Provides safe, effective static neutralization inside a glove box or similar enclosure. Designed for overhead chamber mounting, it generates a balanced stream of positive and negative ions to neutralize surface static charges, safeguarding ESD-sensitive materials. Includes fans for even distribution.
Glove Box IonBar™ (installed)

110VAC, 50/60Hz 220VAC, 50Hz
Cat. # $/Each Cat. # $/Each
22"L with 4 emitters 2005-30 Login
2005-30-220 Login
33"L with 6 emitters 2005-32 Login
2005-32-220 Login
44"L with 8 emitters 2005-31 Login
2005-31-220 Login

Ionization Module Ionization Module
Provide safe, reliable static neutralization for any glove box enclosure.
click here

Vacuum Control Module Vacuum Control Module
Controls vacuum pump operation to maintain desired vacuum level inside the Series 400 vacuum antechamber or pass-through oven.
Cat. # $/Each
1681-75 Login

Magnehelic Guages Magnehelic Gauges
This MAGNEHELIC® Principle is a method of transmitting the effects of changes in air pressure from a diaphragm to an indicating pointer—by means of magnetic linkage and without the use of gears or other direct mechanical linkages. This system avoids wear and physical contact, which might destroy the accuracy and sensitivity of the instrument. It delivers accuracy to within 2% of full scale. Complete information.
MAGNEHELIC® Gauges
Pressure Range
(inches WC)
Weight Uninstalled Installed
Cat. # $/Each Cat. # $/Each
0-0.5 1 lb. 2 ozs. 2625-08 Login
2625-30 Login
0-1.0 1 lb. 2 ozs. 2625-09 Login
2625-31 Login
0-2.0 1 lb. 2 ozs. 2625-10 Login
2625-32 Login
0-3.0 1 lb. 2 ozs. 2625-11 Login
2625-33 Login
0-4.0 1 lb. 2 ozs. 2625-12 Login
2625-34 Login
.25-0-.25 1 lb. 2 ozs. 6600-86 Login

PHOTOHELIC® Pressure Control PHOTOHELIC® Pressure Control
PHOTOHELIC® models combine the MAGNEHELIC® gauge with a precise pressure switch that lets you control low and high gas pressures. Knob controls adjust dual set points, which allow for variable deadband control. These set points contain photocells that actuate DPDT relays when room pressures reach a preset upper or lower limit, and they can be set up to control corrective damper action. As the room pressure changes in response to damper motion, and the indicator returns to the null band, damper motion is halted. Complete information.
PHOTOHELIC® Gauges
Pressure Range
(inches WC)
Weight Uninstalled Installed
Cat. # $/Each Cat. # $/Each
0-0.5 4 lbs. 2625-13 Login
2625-35 Login
0-1.0 4 lbs. 2625-14 Login
2625-36 Login
0-2.0 4 lbs. 2625-15 Login
2625-37 Login
0-3.0 4 lbs. 2625-16 Login
2625-38 Login
0-4.0 4 lbs. 2625-17 Login
2625-39 Login
.25-0-.25 4 lbs. 6600-87 Login

Minihelic II® Differential Pressure Gauges Minihelic II® Differential Pressure Gauges
Combining clean design, small size and low cost with enough accuracy for all but the most demanding applications our Minihelic®II gauge offers the latest in design features for a dial type differential pressure gauge. Complete information.
Minihelic II ® Gauges
Pressure Range
(inches WC)
Weight Uninstalled Installed
Cat. # $/Each Cat. # $/Each
0-0.5 6 ozs. 2625-43 Login
2625-48 Login
0-1.0 6 ozs. 2625-44 Login
2625-49 Login
0-2.0 6 ozs. 2625-45 Login
2625-50 Login
0-3.0 6 ozs. 2625-46 Login
2625-51 Login
0-5.0 6 ozs. 2625-47 Login
2625-52 Login

DIGIHELIC® Differential Pressure Controller DIGIHELIC® Differential Pressure Controller
Allows the selection of pressure, velocity or volumetric flow operation. Two SPDT control relays with adjustable dead bands are provided, with scalable 4-20mA process output. Complete information.
DIGIHELIC® Differential Pressure Gauge
Pressure Range
(inches WC)
Weight Uninstalled Installed
Cat. #
$/Each**
Cat. #
$/Each**
0 – 1.0 14 lbs. 2625-26 Login
2625-40 Login
0 – 5.0 14 lbs. 2625-27 Login
2625-41 Login
1.0 – 0 – 1.0* 14 lbs. 2625-28 Login
2625-42 Login
*Bi-Direction Range. Velocity and volumetric flow not available on bi-directional unit.
**Price includes installation

  4-Outlet Power Strip
Includes master on/off switch and resettable
15-amp circuit breaker. Installed along rear wall of glovebox.
4-Outlet Power Strip
Cat. # $/Each
120VAC, 50/60 Hz 1681-80 Login
Solutions by Industry
Builders(AEC) | Pharmacies
Forensic Labs | Animal Labs
Tech Tips
What makes a glovebox an "isolator"? Or a "mini-environment"? What does "WG" mean? Our glovebox glossary explains . . .
 
QuickQuote Planner
Online Configuration
Online Configuration
QuickQuotes help you specify select systems to your requirements.
 
Need It Right Away?
Blue Prices Indicate QuickShip Items
Blue Prices Indicate QuickShip Items
These ship within a week, usually the very next day. Call for available quantity.
 
Featured Product
Space-Saving Convenience!
Space-Saving Convenience!

Complete line of stainless steel dispensers, racks and bins, now with antimicrobial surface

 
Featured Product
Uncompromising Cleanliness
Uncompromising Cleanliness

BioSafe™ Passthroughs ideal for aseptic environments