Terra Universal - Critical Environment Solutions

Preferred Client

SmartHood™ Ductless Fume Hood

Vertical Laminar Flow Station  
Features Key
  Standard
  Option

A Powder-coated steel hood cover
B Removable baffle system and intake scoop draw fumes away from operator, minimize turbulence that retains fumes
C 1" (25 mm) front lip for spill containment
D Ergonomic air foil minimizes turbulence along entrance
E Adjustable-height, powder-coated steel stand
F Digital control panel with operational displays
G Fluorescent light (externally mounted)
H Chemical-resistant polypropylene fume containment area with plastic fasteners
I Tempered safety glass sliding sash, adjustable from 6" (152 mm) to 29" (737 mm) above work surface
J Air velocity sensor: measures incoming air speed past operator

  • Polypropylene construction provides excellent chemical resistance
  • Smart control system modulates blower speed to maintain constant air velocity past the operator as a function of sash height
  • Activated charcoal filters remove organic fumes for safe indoor release
  • Hydrocarbon sensor detects breakthrough of fumes through charcoal filter
  • Audible and visible alarms indicate unsafe operating conditions: low entrance air velocity, carbon filter breakthrough, excessive backpressure across HEPA filter
  • Baffle system optimizes fume ventilation, can be removed for easy cleaning
  • Differential pressure gauge monitors HEPA pre/post filters to ensure clean conditions, inside and out
  • Provides spacious working area yet fits through standard doorway
  • Options include service utilities and monitoring of relative humidity, temperature, pH

SmartHood Filter
Front Access to Filters —
Quick-release holders securely position HEPA and 1 – 3 charcoal filters
SmartHood armrest
Full-width ergonomic air foil: minimizes turbulence and provides a comfortable, flexible arm rest (elevated arm rest available)

SmartHood Airflow Diagram
Baffle system optimizes non-turbulent flow away from operator
Terra’s SmartHood™ Ductless Fume Hood ventilates and removes organic vapors released inside the hood to allow safe recirculation of exhaust into the room.

Polypropylene construction offers excellent chemical resistance, and a 1" (25 mm) front lip provides a safe spill containment area. The airflow baffling system minimizes airflow turbulence that could result in backflow toward an operator or retain fumes inside the hood. The onboard fan module draws fumes safely toward the rear of the containment area and directs them into activated carbon filters, which remove chemical fumes from the exhaust flow. Terra’s bonded charcoal filters minimize particle sloughing and eliminate voids that can allow chemical bypass of the charcoal media.

HEPA filters may be installed inside the hood to remove submicron particles, including aerosols that cling to dust. An external HEPA filter module is also available for final filtration, allowing air recirculation into a cleanroom environment.

Smart Controller Maintains Constant Air Velocity

The SmartHood controller automatically modulates the fan speed to maintain a constant airflow velocity, typically 100 feet/minute (.51 m/s), past the operator as the sash height or HEPA filter backpressure changes. The measured air velocity is displayed on the LCD readout. The constant velocity set point, programmable on the touchpad control, helps meet provisions of ASHRAE 110-95 test protocol.

The controller also provides several audible and visible safety alarms:

  • Airspeed alarm: Alarms signal if measured air speed past the operator falls below set point value, typically 100 ft./minute (.51 m/s).
  • Charcoal filter breakthrough: A hydrocarbon sensor monitors integrity of the charcoal filter. When “breakthrough” is detected, the controller issues a warning alert to change the filter.
  • HEPA backpressure alarm: When pressure differential exceeds a programmable limit, the controller issues an alert to indicate the need to replace the HEPA filter(s).
  • Elapsed time alarm: Based on predicted filter lifetime, a timer can be used to signal the need for filter replacement before “breakthrough.” Secondary timers can be programmed to issue elapsed-time alerts for process operations.
  • Process alerts: When probes for monitoring relative humidity, pH and temperature are installed, alarms can be programmed to indicate that specified process limits are exceeded.

The SmartHood includes a fluorescent light, mounted externally, and a 12" (305 mm)-dia. x 2"H (51 mm) exhaust flange mounted at the top rear of the unit.

SmartHood™ Ductless Fume Hood (order desired filters separately) 120VAC; for 220V, add “-220” (5588 mm) to the part number
Overall
Dimensions
W x D x H
inches
(mm)
Working Area
W x D x H
inches
(mm)
No. of
Fans
No. of
Filter Packs**
Airflow Exhaust
Volume (CFM)***
SmartHood™
Cat. # #/Each
36 x 34 x 60
(914 x 864 x 1524)
35 x 28 x 32
(889 x 711 x 813)
2 2 500
(.24 m³/s)
2148-30 Login
48 x 34 x 60
(1219 x 864 x 1524)
47 x 28 x 32
(1194 x 711 x 813)
2 2 500
(.24 m³/s)
2148-31 Login
60 x 34 x 60
(1524 x 864 x 1524)
59 x 28 x 32
(1499 x 711 x 813 )
3 3 750
(.36 m³/s)
2148-32 Login
72 x 34 x 60
(1829 x 864 x 1524)
71 x 28 x 32
(1803 x 711 x 813)
3 3 750
(.36 m³/s)
2148-33 Login
96 x 34 x 60
(1753 x 864 x 1524)
95 x 28 x 32
(2413 x 711 x 813)
4 4 1,000
(.47 m³/s)
2148-34 Login
** Each filter pack accommodates up to one HEPA/ULPA filter and two charcoal filters (order desired filters separately).
*** Tested under filter load (one HEPA and one charcoal filter/pack).

Stands and Work Surface for SmartHood
For SmartHood
number in
above chart
Powder-Coated
White Stand
Removable Stainless
Steel Work Surface*
Cat. # #/Each Cat. # #/Each
2148-30 2148-35 Login
2148-40 Login
2148-31 2148-36 Login
2148-41 Login
2148-32 2148-37 Login
2148-42 Login
2148-33 2148-38 Login
2148-43 Login
2148-34 2148-39 Login
2148-44 Login
* Prevents scratches. Not intended for use with acids, which corrode stainless steel.
  Casters
(set of 4, 2 with brakes)
Cat. # $/Each
1700-44 Login

Optional Accessories
Activated Charcoal Filter
Bonded to prevent filter voids and charcoal sloughing. Includes prefilter. 12" x 24" x 1.75" (305 x 610 x 44 mm); select up to two for each filter pack.
Cat. # $/Each
2148-45 Login
  Relative Humidity Probe
Cat. # $/Each
2148-49 Login

     
HEPA Filter
Rated 99.99% efficient at particles ≥ 0.5µm.
  Cat. # $/Each
12" x 24" x 3"
(305 x 610 x 76 mm)
for installation in filter pack
2148-46 Login
12" x 12" x 3"
(305 x 305 x 76 mm)
for exit post-filter
2100-30 Login
  pH Probe
Cat. # $/Each
2148-50 Login
     
Exit Filter Housing
Polypropylene, included 12"-dia. X 2"H flange (305 x 51 mm)
Cat. # $/Each
2148-48 Login
  Temperature Probe
Cat. # $/Each
2148-51 Login
     
GFI Power Outlet (2 outlets)
Includes remote on/off switch; ideal for pumps and other process equipment.
  Cat. # $/Each
120VAC 2148-52 Login
  UV Sterilization Light
Fixture and tube (254nm wavelength)
Hood Width Cat. # $/Each
36"
(914 mm)
2148-55
call TUI
48"
(1219 mm)
2148-56 call TUI
50"
(1270 mm)
2148-57 call TUI
72"
(1829 mm)
2148-58 call TUI
96"
(2438 mm)
2148-59 call TUI
Click to leave a message. 24-hour sales and tech phone support, M - F
Technical Questions?
Schedule a call with a
Terra tech specialist.