Purifier® Logic™ Class II Biosafety Cabinets |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Purifier® Logic™ Biosafety Cabinets set the standard for safety, performance and ergonomics. These cabinets have been completely redesigned from the Delta Series cabinets they replace. They meet or exceed all the standards set forth by the NSF International, including 99.99% efficient HEPA filters, nominal inflow of 105 fpm, and all positive-pressure ducts surrounded by negative pressure plenums. Computerized Monitoring of Purifier® Logic™ Class II Biosafety Cabinet OperationPurifier Logic Biosafety Cabinets utilize Electronically Commutated Motor (EMC) Technology, which precisely controls airflow without the need for airflow sensors. The motor is programmed during the cabinet’s manufacturing process to consistently deliver the precise volume of air required, even as filters load.A unique line-of-sight LCD information center, which is in constant communication with the ECM, continuously monitors and displays the cabinet’s performance, including remaining HEPA filter life. Other intelligent safety features include the Smart-Start and Night-Smart Systems. Smart-Start allows the user to program start-up and shut-down procedures such as activation and deactivation of the blower and fluorescent and UV lights when the sash is opened or closed. Automating routine start-up and shut-down procedures assures consistent, operator-independent operation and saves time. Night-Smart idles the blower at 30% speed or less when the sash is fully closed to help maintain a clear, particulate-free environment inside the cabinet during periods of non-use.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Purifier® Logic™ Class II Biosafety Cabinet:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Specification | Purifier Logic |
Other Biosafety Cabinets |
| Power During Operation (watts) | 240 | 582+ |
| Power in Night-Smart mode (watts) | 30 | n/a |
| Heat (BTU/hour) | 67 | 110+ |
| Noise Level (dBA) | 62 | 65+ |
| Fluorescent Light Level (footcandles) | 90-100 | 65 |
| Average Motor Life (hours) | 50,000 | 10,000-15,000 |
Compared to biosafety cabinets with conventional motors, the Purifier Logic Biosafety Cabinet uses 58% less energy during normal operation and over 94% less energy during Night-Smart operation. It also generates 39% less heat and is as much as 50% quieter and 53% brighter (depending on the model) and has a 230-400% longer motor life.
| Purifier Logic Biosafety Cabinets* |
||||||
| Nominal Width |
Purifier® Logic Series |
Purifier® Logic Series |
||||
| Labconco Part # | Cat.# | $/Each | Labconco Part # | Cat.# | $/Each | |
| 3 feet | 3430800 | 3645-43 |
Login |
3430801 | 3645-40 |
Login |
| 4 feet | 3440800 | 3645-45 |
Login |
3440801 | 3645-41 |
Login |
| 5 feet | 3450800 | 3645-47 |
Login |
3450801 | 3645-46 |
Login |
| 6 feet | 3460800 | 3645-44 |
Login |
3460801 | 3645-42 |
Login |
| Purifier Logic Biosafety Cabinet Canopy Kit and Safety Blower |
||||||
| Nominal Width |
Canopy Kit*** | Remote Blower | ||||
| Labconco Part # | Cat.# | $/Each | Labconco Part # | Cat.# | $/Each | |
| 3 feet | 3898000 | 3645-48 | Login
|
7068000 | 3645-52 | Login
|
| 4 feet | 3858701 | 3645-49 | Login
|
7068000 | 3645-52 | Login
|
| 5 feet | 3858702 | 3645-51 | Login
|
7068000 | 3645-53 | Login
|
| 6 feet | 3858708 | 3645-50 | Login
|
7068000 | 3645-53 | Login
|
![]() |
![]() |
![]() |
|
| Telescoping – Epoxy-coated 1.75” tubular steel. Adjustable at installation in 1” increments to provide a working height from 30” to 36”; 29”D. Specify fixed leveling feet or toe-locking casters. | Hydraulic Lift Stand – Epoxy-coated 1.75” tubular steel with 2” x 3” tubular steel subframe. Infinitely adjustable from 25.5” to 33.5” high; 24”D. Fixed feet and manual hand-crank lift. | SoLo™ Hydraulic Lift – Allows cabinet transport through standard doorways as low as 78”H. Epoxy-coated steel, Remote-control operated hydraulic lift provides infinitely adjustable work surface heights from 17.2” to 36.8”H; 34.3”D. Includes toe-locking 5”-diameter casters |
| Stands: Telescoping | ||||||
| Cabinet Width |
Telescoping Stand | |||||
| Leveling Feet | Toe-Locking Casters | |||||
| Labconco Part # | Cat. # | $/Each | Labconco Part # | Cat. # | $/Each | |
| 3 feet | 3730200 | 3645-26 |
Login |
3730310 | 3645-55 |
Login |
| 4 feet | 3730400 | 3645-27 |
Login |
3730410 | 3645-56 |
Login |
| 5 feet | 3830500 | 3645-54 |
Login |
3830510 | 3645-57 |
Login |
| 6 feet | 3730600 | 3645-28 |
Login |
3730610 | 3645-58 |
Login |
| Hydraulic Lifts | ||||||
| Cabinet Width |
Hydraulic Lift | SoLo Hydraulic Lift* | ||||
| Labconco Part # | Cat. # | $/Each | Labconco Part # | Cat. # | $/Each | |
| 3 feet | 3780200 | 3645-59 | Login
|
3780310 | 3645-63 | Login
|
| 4 feet | 3780201 | 3645-60 | Login
|
3780311 | 3645-64 | Login
|
| 5 feet | 3780203 | 3645-61 | Login
|
3780312 | 3645-65 | Login
|
| 6 feet | 3780202 | 3645-62 | Login
|
3780313 | 3645-66 | Login
|
Type A2 Biological Safety CabinetsThe diagram below illustrates the airflow pattern of an A2 Biosafety Cabinet. Type A2 cabinets are suitable for work with agents the require Biosafety Level 1, 2 or 3. Other appropriate applications include work with antioneplastic drugs, genetic material, carcinogens, allergens and additional substances that generate hazardous airborne particulates. Purifier Logic Class II, Type A2 Biosafety Cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-connected, the biosafety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and trace amounts of radionuclides as an adjunct to microbiological research. These benchtop cabinets are available in three-, four-, five- and six-foot nominal widths. |
![]() |
|