Chart Recorders — Temperature, Humidity, and Dew Point |
|
TH800
Designed with a compact and rugged enclosure, this chart recorder provides accurate record for temperature, humidity, and dew point. This unit has a large 8" chart for easy reading and user selectable temperature ranges and recording times. Included are four AA batteries, pens, and standard Certificate of Calibration. NIST-Traceable Certification of Calibration is also available. See chart below for pricing. Chart paper sold separately. |
| Specifications |
| Temperature Range: |
+32 to +120ºF, 0 to +50ºC (user selectable) |
| Humidity Range: |
0 to 95% RH (non-condensing) |
| Dew Point Range (Calculated): |
32 to +122º (0 to +50ºC) |
| Ambient Operating Conditions: |
+32 to +120ºF (0 to +50ºC), 0 to 95% RH (non-condensing) |
| Temperature Sensor: |
Digital Sensor |
| Humidity Sensor: |
Monolithic IC Humidity Sensor |
| Temp. Accuracy: |
±1.8ºF (±1ºC) |
| Humidity Accuracy: |
±2% from 0 to 60% and ±3% from 60 to 95% |
| Dew Point Accuracy (Calculated): |
10% to 95% RH: ±7.2ºF (±4ºC) |
| Average Response Time: |
Temperature/RH: 2 minutes for a 63% step charge at 10 FTM airflow |
| Recording Time: |
24 hour, 7 day (user selectable) |
| Chart Size: |
8” |
| Power Supply: |
four AA batteries |
| Weight: |
4lbs |
| Dimensions: |
9.2”x9.2”x3.1 |
|
TH800 Chart Recorder
| |
Cat.# |
$/Each |
| 24-hour -20 to +120ºF |
4801-66 |
Login
|
Requires Dickson chart paper and pens below. Use of other supplier materials could cause recorder to operate incorrectly.
Chart Paper
| |
Cat.# |
$/Each |
| 24-hour -20 to +120ºF |
4801-33 |
Login
|
| 7-day -20 to +120ºF |
4801-34 |
Login
|
| 24 hour, -20 to 120ºF |
4801-57 |
Login
|
| 7 day, -20 to 120ºF |
4801-58 |
Login
|
|
|
Replacement Pen Pack
| |
Cat.# |
$/Each |
| 3 red & 3 blue |
4801-40 |
Login
|
NIST-Traceable Certificate of Calibration
Must be specified when Chart Recorder is ordered
| |
Cat.# |
$/Each |
| 1-point |
4801-21 |
Login
|
| 3-point |
4801-22 |
Login
|
|
|
|
TH803
User-selectable microprocessor lets you determine scale ranges
and recording times (1, 7, or 31 day). Charts are 8"
diameter. Temperature sensor: thermistor. Humidity sensor:
monolithic IC. Includes audio/visual high and low alarms.
Comes standard with pens, one AC
adapter, 9V battery and certificate of calibration.
|
| Specifications |
| Temp. Ranges: |
-20 to +120°F, +40
to +110°F, 0 to 185°F, -2
0 to +50°C and +5 to +40°C |
| Temp. Accuracy: |
± 1.8°F (±
1.0°C) |
| Humidity Range: |
0 - 95% RH (non-condensing) |
| Humidity Accuracy: |
± 2% from 0 -
60% ± 3% from 60 to 95% |
| Dew Point Range: |
-22 to 122°F, -30
to +50°C |
| Dew Point Accuracy: |
± 7.2°F (±
4°C) |
| Display Resolution: |
1°F (1°C), 1%
RH |
| Response Time: |
Temp/RH: 2 min for a 63% step charge at 10 FTM airflow |
| Power Supply: |
120VAC or 220VAC adapter |
| Dimensions: |
9.2" x 9.2" x 3.1" (23.4cm x 23.4cm x 7.9cm) |
| Weight: |
4 lbs. (1.8g), with
batteries |
|
| TH803 — Chart Recorder |
Cat.# |
$/Each |
| |
110VAC |
4801-65 |
Login
|
| |
220VAC
(CE marked) |
4801-65-220 |
Login
|
| NIST-Traceable
Certificate of Calibration (1-point) |
4801-21 |
Login
|
| NIST-Traceable
Certificate of Calibration (3-point) |
4801-22 |
Login
|
| Replacement
Pen Pack (3 red and 3 blue) |
4801-40 |
Login
|
Requires Dickson chart paper and pens below. Use of other supplier materials could cause recorder to operate incorrectly.
Chart
Paper for the
Temp/Humidity/Dew Point Recorder (60 Charts per Pack) |
| Temp
Range |
Recording
Time |
Cat.# |
$/Pack |
| -20
to +120°F |
24-hour |
4801-33 |
Login
|
| -20
to +120°F |
7
day |
4801-34 |
Login
|
| -20
to +120°F |
31-day |
4801-56 |
Login
|
| -20
to +50°C |
24-hour |
4801-57 |
Login
|
| -20
to +50°C |
7
day |
4801-58 |
Login
|
| -20
to +50°C |
31-day |
4801-59 |
Login
|
| +40
to +110°F |
24-hour |
4801-35 |
Login
|
| +40
to +110°F |
7
day |
4801-36 |
Login
|
| +5
to +40°C |
24-hour |
4801-60 |
Login
|
| +5
to +40°C |
7
day |
4801-61 |
Login
|
|