More Products
Picture 21
A. DewWatch™ Humidity Controller
B. Glove Box Dual Purge™ System
C. Air Lock
D. 4-Port Twin Chamber (No. 1694-04)
E. Vacuum Nitrogen Pump
F. Pass-Through Oven (No. 5401-00A)
Optional gas purge controls automatically—
  • establish a Class 1 particle-free environment
  • maintain a humidity set point down to 0% RH/0.5 ppm(v) H2O
  • minimize system recovery time
  • provide precise gas mixtures for leak testing and other processes
Configure a turnkey system to your process specifications—
  • Humidity Controllers
  • Process Gas Mixers
  • Gas Cooler/Heater
  • Recirculation Filtration Module
  • Pass-Through Ovens
  • More!
Air-Lock
Air Lock Provides
Convenient Access.
Picture 22
A. NitroWatch®
B. Dual Purge™ System
C. Vacuum control Module
D. Modualr Vacuum Oven
Series 300 Dim. Illust Series 300 Dim. Illust
Series 300 Dim. Illust  
Model Glove ports A D E F G H I M N
Single 2 16.56 24 28.25 35 11.75 24 16 14.75 11
Twin 4 16.56 24 54.75 59 11.75 24 16 14.75 11
Specifications
Door Openings: 12.5" x 12.5" with gasketed doors supplied with air locks (see ordering information below); doors open inward.
Arm Ports: 9" round with flange for connecting glove assembly
Gas Ports: Tapped .75 " NPT inlet (for connecting flowmeter or Dual Purge™ System) and .75" NPT system pressure port; .75" NPT outlet (for connecting Terra Automatic RB® Valve). Appropriate adapter inserts are supplied for any Terra gas systems ordered.
Light: 120VAC/60Hz fluorescent. For 220VAC/50Hz, add "-220" to the part number

Stainless Steel Glove Boxes

  • Provides a clean, air-tight, controlled environment for a wide range of forensic applications
  • Air Lock features recessed polyurethane seals and heavy-duty latches and hinges for enhanced durability and sealing performance
  • Side flanges simplify insertion/removal of process equipment and allow easy addition of ovens and air locks
  • Removable arm ports can be interchanged to meet specific requirements and accept a wide variety of gloves
  • Select single model (with two glove ports) or twin model (with four glove ports)

The Stainless Steel Controlled Atmosphere Chamber provides a hermetically sealed environment for such operations as tissue analysis or other forensic testing.

A wide safety glass viewing window is tightly installed using gasketed seals that ensure minimum vapor loss and stand up to positive pressures. A fluorescent light fixture, cord and switch are mounted to the exterior of the chamber to ensure proper illumination without contaminating the internal environment or posing a combustion hazard in the presence of flammable gases.

Nitrogen Controls Ensure Low-Humidity, Contamination-Free Atmosphere
Two plugged .75" NPTF openings—an inlet in the upper left corner of the back panel and an outlet in the lower right corner of the back panel—allow you to purge the chamber with nitrogen in order to guarantee an environment free of contaminants and moisture. For optimal processing conditions, select Terra's Glove Box Dual Purge™ System and NitroWatch®, which work in tandem to provide completely automatic gas purging.

The Dual Purge System delivers a variable nitrogen purge into the glove chamber. During normal operation, it provides a continuous low-flow purge to maintain a positive pressure that blocks out contaminants. In the event of a sudden pressure drop, it activates a high-flow purge to block out contaminants and to quickly purge any moisture or particles that do enter the chamber.

The NitroWatch provides automatic low-humidity control. It monitors the internal relative humidity, and activates the high-flow purge when the moisture climbs above an adjustable set point. For ultra-low humidity requirements, select the DewWatch™ instead, which works with the Dual Purge System to automatically maintain moisture levels as low as 0.5 PPM(v). The Automatic RB® (Relief/Bleed) Valve ensures safe pressure relief with these control systems and also functions as a check valve, ensuring that no moisture or contaminants enter the chamber in the event of a negative pressure. For economical operation, gas can be directed from the RB Valve outlet to an adjacent air lock, thereby conserving nitrogen consumption.

Select the single or twin model; twin glove boxes feature two pairs of glove ports to accommodate two operators (order gloves separately). Other system options include a filter/blower module for filtering and recirculating purge gas or purifying exhaust; self-balancing ionizing equipment for complete static safety; and a variety of gas mixers and analyzers for use in precisely controlled gas environments.

Note: These glove boxes are designed for use under positive or low-level (to 1" Hg) negative pressures. Higher-level vacuums (to 29.9" Hg) can be achieved in Terra's Vacuum Antechamber, which operates with the Series 400 chambers.

Convenient Access, Optimal Versatility
These chambers come standard with removable arm ports (two or four, depending on the model selected) that are double-gasketed and bolted to the chamber wall for strength and optimal seal integrity. They can be easily removed and replaced with custom ports designed to meet specific requirements. (Order gloves separately.)

Like our other stainless steel chambers, all models also feature side access flanges that allow easy attachment of Terra's process modules (ovens and air locks) and also permit "cascading" of several chambers in series. These flanges are easy to remove and reinstall and feature a "U-channel" double-gasketed seal that guarantees the integrity of the internal environment.

Air Locks Allow Convenient Access
These glove boxes can be outfitted with air locks that maintain the integrity of the controlled environment without sacrificing convenience.

All air locks are pre-mounted to a side flange that is easy to install on the chamber; select locks for right- or left-side installation. They minimize nitrogen loss and contamination inflow while parts are introduced or removed, particularly when equipped with their own gas controls. Their safety glass viewing windows are sealed with one-piece, nonadhesive compression gaskets. On a custom basis, air locks can be ordered with dual mounting flanges to "cascade" several atmospheric chambers in series. All air locks include a .125" NPT pipe-tapped opening for connection of purge gas and a .25 " NPT outlet to accommodate an Automatic RB® (Relief/Bleed) Valve.

Note: For vacuum requirements up to 29.9" Hg, select a Series 400 Atmospheric Chamber along with Terra's Vacuum Antechamber.

Series 300 Atmospheric Chamber
Corresponding Air Locks
  120VAC 220VAC Right Side Left Side $/Each
Cat. # $/Each Cat. # $/Each Cat. # Cat. #
Single 1694-01B Login 1694-01B-220 Login 1702-10B 1702-11B Login
Twin 1694-02B Login 1694-02B-220 Login 1702-10B 1702-11B Login
 
IonBar™ (installed below Filter/Fan)
Safe static neutralization.
Cat. # $/Each
33" Long 2005-38 Login
44" Long 2005-37 Login
169411  

Stands for Series 300 Glove Boxes
Constructed of all-welded 1.5" square tubing. Select oven support for use with Terra's High-Performance Pass-Through Oven (No. 5401-00A). All stands raise chambers 30" off of floor (add 3" for casters).

No. 1694-11

Powder-Coated Steel Stainless Steel
Chamber Only Chamber and Oven Chamber Only Chamber and Oven

Cat. #

$/Each

Cat. #

$/Each

Cat. #

$/Each

Cat. #

$/Each
For Single Models (2 ports) 1690-03 Login 5401-01 Login 1694-09 Login 1694-11 Login
For Twin Models (4 ports) 1690-04 Login 5401-02 Login 1694-10 Login 1694-12 Login
A. Glove Port     B. Port Cover     C. Iris Adapter  
glove port glove ports glove port port cover glove port glove ports
10"-diameter port is standard on all Terra gloveboxes. Order covers and iris adapter separately.
Complete Information
  Cat. # $/Each
A. Replacement Glove Port 1694-52 Login
B. Port Cover 1694-53 Login
C. Iris Port 1694-54 Login

Cat. #

$/Each
Heavy-Duty Casters (set of 4, 2 with brakes) 1700-44 Login
Other Optional Accessories
Cat. # $/Each
Dual Purge System 1603-57 Login
NitroWatch System 9500-00A Login
NitroWatch Sensor 9500-02A Login
Stainless Steel Automatic RB Valve
Required for operation with Dual Purge System
1606-60 Login
Accordion Sleeve/Glove Combination
(18"L, with size 9 gloves)
1681-91B Login
High-Performance Vacuum Oven Click here
Modular Vacuum Oven
Click here
Plastic Arm Ports 1694-52 Login
Operating Manual 1800-13 Login
 

More Products
 

Top of Page

714-578-6000

All prices and specifications are subject to change without notice. Crating charges apply to selected items.
Call or click here for more information on terms and conditions.

© 1998-2007 Terra Universal, Inc. All rights reserved.

Preferred Client
Services Include:
QuickStart Manuals
Price Checker
Update Profile
You are not logged in.
Type email address and click Login.