| ±1%RH |
| |
RH/Temperature
Indicator
(includes temperature/humidity probe, case and ceretificate)
| Cat.
# |
$/Each |
|
3710-04 |
Login |
|
| |
NIST Certificate
of Calibration
For #3710-04 (must be specified when indicator is
ordered)
| Cat.
# |
$/Each |
|
3710-06 |
Login |
|
| |
Carrying Case
| Cat.
# |
$/Each |
|
3710-05 |
Login |
|
RH/Temperature Indicator
- ± 1% RH (0-90%), ± 2% (90-100%)
- Measures temperature from -40 to + 212° F
(up to 356°F for short periods)
- Calculates dewpoint, wet bulb temperature, absolute humidity
and mixing ratio
- Serves as an easy-to-use field calibrator
- Data collection capability, with serial line download
to PC
This hand-held indicator can be used for spot checking humidity
and temperature in cleanrooms, HVAC systems, storage enclosures,
and environmentally sensitive areas.
In addition to displaying %RH and temperature readings, it
also calculates dewpoint and wet bulb temperature, absolute
humidity, and mixing ratio, freeing you from awkward conversion
tables and complex calculations. The indicator features an
easy-to-read two-line liquid crystal display, with metric
and non-metric readout.
The Temperature/Humidity Probe features a stainless steel
head made to withstand rough handling. The probes long
shaft is perfect for cramped, inaccessible spaces. The HUMICAP®
sensor provides high accuracy, excellent long-term stability,
and negligible hysteresis. It is insensitive to dust, particulates
and most chemicals.
This easy-to-use instrument offers fast response time, high
measurement accuracy, excellent stability, and a wide measurement
range, making it ideal for field calibration and other demanding
applications.
| Specifications
Indicator: |
| Accuracy (@ +20°C): |
±1 %RH; ± 0.1°C |
| Resolution: |
0.1 %RH; 0.1°C |
| Power Supply: |
4 batteries, type AA (LR 6) |
| Battery Life: |
72 hours continuous use |
| Operating Temperature: |
-4 to +140°F (-20 to +60°C) |
| Display: |
Two-line LCD |
| Housing Material: |
ABS plastic |
| Dimensions: |
80mm x 37mm x 200mm |
| Weight: |
300 g (including batteries) |
| Temperature/Humidity
Probe: |
| Measurement Range : |
0 to 100 %RH non-condensing
-40 to +100°C continuous
-40 to +180°C short-term |
| Accuracy
(@+20°C): |
| Humidity: |
± 1% RH (from 0 to
90%RH); ± 2%RH (from 90 to 100% RH) when properly
calibrated |
| Temperature: |
± 0.2°C |
| Stability: |
Better than 1% per year (typical) |
| Response Time: |
15 seconds (90%RH at +20°C) |
| Temperature Sensor:
|
IEC 751 .333 class B-RTD P+1000 |
| Operating Temperature:
|
-20 to +60°C |
| Dimensions: |
38mm x 30mm x 440mm |
| Cable Length: |
150mm; extended spiral cable |
| Weight: |
450 g |
|