General Use Laboratory Refrigerators/Freezers
Choose from a complete line of refrigerators, freezers, and combination refrigerator/freezers designed for general laboratory use. Capacities range from 1.7 to 20 cubic feet. Refrigerator temperatures range from 2° To 7°C (36° to 45°F); freezer temperatures from -26° to 0°C (-15° to 32°F). Some models are available in either 120 volts/60 Hz or 240 volts/50 Hz. All models come with a 24-month warranty. |
|
 |
| 1720-43 |
Undercounter Refrigerator
This 5.6 cubic ft. undercounter unit comes with 3 adjustable wire shelves and a hydraulic thermostat control. Temperature range is 2°To 7°C (36° To 45°F).
|
|
|
Undercounter Laboratory Freezer (not shown)
This freezer features 5.6 cubic feet of storage
space and a conveniently customizable door which can
be interchangeably installed to open either to the left
or to the right. The cabinet and door are enameled steel,
and the ABS plastic liner has rounded corners for easy
cleaning. Both cabinet and door contain foamed-in polyurethane
insulation and a magnetic gasket to provide a secure
seal and increased energy savings. Adjustable thermostatic
control maintains a temperature range of -26° to
-15°C (-15° to 5°F). With rust-proof
shelf. Manual defrost.
Compact Benchtop Laboratory
Refrigerator/Freezer (not
shown)
This convenient, space-saving unit features
an overall capacity of 1.9 cubic feet. Refrigerator
temperature range: 0° to 7°C (32° to
45°F); freezer temperature range: -5° to 0°C
(23° to 32°F). |
|
 |
| 1720-49 |
Two-Door
Laboratory Refrigerator/Freezer
This refrigerator/freezer has an independent door for both the refrigerator section and the freezer section. Overall capacity is 17.9 cubic feet. Refrigerator temperature ranges from 0° to 10°C (32° to 50°F); freezer temperature ranges from -20° to 0°C (-4° to 32°F). With two adjustable shelves, and 4 door shelves, ABS plastic interior, white enameled steel exterior. Automatic defrost. |
|
 |
| 1720-47 |
Undercounter Laboratory Refrigerator/Freezer
You can use this versatile model as either an undercounter
built-in or a free-standing unit. The temperature
range in the refrigerator compartment is from 2°
to 7°C (36° to 45°F) and may be set
to the desired temperature by the adjustable thermostatic
control. The temperature range in the freezer compartment
is from -15° to 1 °C (5° to 33°F).
The freezer compartment has room for eight standard
ice trays or for a supply of biologicals or chemicals
of comparable volume.
|
|
 |
| 1720-60 |
Lab Refrigerator/Freezers
Refrigerator/Freezer: These units come in 2 configurations. A 14 cubic-ft. two-door refrigerator/freezer features hydraulic thermostatic control and separate "cold air flow" control for the freezer. It includes 2 adjustable shelves and automatic defrost.
Freezer: A 20 cubic-ft. upright freezer features 4 fixed wire shelves and 6 door shelves and comes with manual defrost. Temperature range: 0° to 10°C (refrigerator compartment); -20°C to 0°C (freezer compartment). Models below are 120VAC; 240VAC and explosion-proof models available. |
|
| Specifications
and Ordering Information: Laboratory Refrigerators/Freezers |
| Model |
Net
Wt.
lbs
(kgs) |
Ship.
Wt.
lbs
(kgs) |
Chamber Dimensions
W" x D" x H" (cms) |
Total
Vol.
(cu. ft.) |
Exterior Dimensions
W" x D" x H" (cms) |
Specs continue
in next chart |
Refrigerator
Section |
Freezer
Section |
Undercounter
Refrigerator |
|
120
(55) |
20.5 x 13.5 x 27.5
(52 x 34 x 70) |
N/A |
5.6 |
23.75 x 25.5 x 33.5
(60 x 65 x 85) |
1720-43 |
Undercounter Lab
Refrigerator/Freezer |
100
(46) |
120
(54.5) |
18 x 15.5 x 21
(46 x 39 x 53) |
15.5 x 11 x 6
(39 x 28 x 15) |
5.6 |
23.75 x 25.5 x 33.5
(60 x 65 x 85) |
1720-47 |
| 1720-47-220 |
Two-Door Lab
Refrigerator/Freezer |
170
(77) |
240
(109) |
26 x 24 x 37.5
(66 x 61 x 95) |
24 x 21 x 17
(61 x 53 x 43) |
17.9 |
31 x 30 x 66
(79 x 76 x 168) |
1720-49 |
Two-Door Lab
Refrigerator/Freezer |
|
150
(68) |
19.5 x 13.5 x 39
(50 x 34 x 91) |
18 x 17 x 12
(46 x 43 x 30) |
10.1 |
23.5 x 31 x 60.75
(60 x 79 x 154) |
1720-49-220 |
Compact Lab
Refrigerator/Freezer |
46
(21) |
52
(24) |
16 x 9 x 15
(41 x 23 x 38) |
6 x 8 x 6
(15 x 20 x 15) |
1.9 |
18.5 x 21.5 x 19
(47 x 55 x 48) |
1720-53 |
Undercounter
Lab Freezer |
100
(46) |
120
(54.5) |
N/A |
18 x 15 x 28
(46 x 38 x 71) |
5.6 |
21.5 x 26.5 x 35.5
(55 x 67 x 90) |
1720-54 |
| Freezer |
|
240
(109) |
N/A |
27 x 22.5 x 56
(69 x 57 x 142) |
20 |
32.5 x 28.5 x 71
(83 x 72 x 180) |
1720-60 |
| 1720-60-220 |
| Specifications
and Ordering Information: Laboratory Refrigerators/Freezers —Continued |
| Model |
Temp. Range |
Electrical
Characteristics |
Cat. # |
$/Each |
Refrig.
Section
°C (°F) |
Freezer
Section
°C (°F) |
Watts |
Volts/Hz |
Undercounter
Refrigerator |
2° to 7°
(36° to 45°) |
N/A |
160 |
120/60 |
1720-43 |
Login |
Undercounter Lab
Refrigerator/Freezer |
2° to 7°
(36° to 44°) |
-15° to 1°
(5° to 33°) |
160 |
120/60 |
1720-47 |
Login |
| 240/50 |
1720-47-220 |
Login |
Two-Door Lab
Refrigerator/Freezer |
0° to 10°
(32° to 50°) |
-20° to 0°
(-4° to 32°) |
420 |
120/60 |
1720-49 |
Login |
Two-Door Lab
Refrigerator/Freezer |
1° to 10° C
(34° to 50°F) |
-17° to -6°C
(-1° to 21°F) |
360 |
120/60 |
1720-49-220 |
Login |
Compact Lab
Refrigerator/Freezer |
0° to 7°
(32° to 45°) |
-5° to 0°
(23° to 32°) |
132 |
120/60 |
1720-53 |
Login |
Undercounter
Lab Freezer |
N/A |
-26° to -15°
(-15° to 5°) |
130 |
120/60 |
1720-54 |
Login |
| Freezer |
N/A |
-20° to -12°
(-4° to 10°) |
870 |
120/60 |
1720-60 |
Login |
| 240/50 |
1720-60-220 |
Login |
|
| |