Cleanroom Wall & Ceiling Grid Conversions

35 products meet your criteria.

per page
  1. GLASBORD® Cleanroom FRP Wall Panels by Crane Composites
    StockedStocked
    3 Fire Rating6 Size

    Available Fire Rating: Class A, Class C, Class A, Factory Mutual
    Available Size: 4' x 8', 4' x 9', 4' x 10', 4' x 12', 3.75" x 3.75", 7.4" x 7.4"
  2. Cleanroom Ceiling Grids
    Cleanroom Ceiling Grids
    Group of 2 products
    From
    Request Quote
    Some ship in 20 - 26 days
    2 Material

    Available Material: Powder-Coated Steel, 304 Stainless Steel
  3. Cleanroom Wall Partitions
    Cleanroom Wall Partitions
    Group of 4 products
    From
    Request Quote
    4 Material

    Available Material: Acrylic, Static-Dissipative PVC, Polycarbonate, Polypropylene
  4. Cleanroom Curtains and Strip Shields
    Stocked
    Cleanroom Curtains and Strip Shields
    Group of 10 products
    From
    $55
    Some ship in 1 - 3 days
    StockedStocked
    2 Curtain Type2 Material3 Width4 Height

    Available Curtain Type: Curtain Panel, Strip Shield
    Available Material: Clear Polysim, Anti-Static PVC
    Available Width: 48", 12", 8"
    Available Height: 8', 10', 6.5', 7.5'
Page 1 of 1

35 products meet your criteria.

per page



Can't find what you're looking for?
Tell us what you need and we'll build it!



SUBMIT A QUICKQUOTE REQUEST


Need Help?

(714) 578-6100

EMAIL CHAT

Mon - Fri, 5:30am - 5:30pm PST

Features and Benefits

Available Environmental Control System

Standard cleanroom comes with analog pressure gauge and on/off controls; optional touchscreen FFU controller monitors, controls and logs internal pressure, as well as displaying temperature and RH.

BioSafe Cleanroom Sterilization

Ceiling filter covers allow wash-down and sterilization of cleanroom walls and ceilings to ensure sterile conditions; smooth, crevice-free glass and stainless steel wall panels stand up to biocides.

Germicidal UV Lamp Sanitizes Labs, Cleanrooms

UV-C Germicidal Lamp installs on a cleanroom ceiling grid for line-of-sight room disinfection; safety occupancy sensor prevents personnel exposure.

Cleanroom Conversions

  • Modular Cleanroom Ceiling Grid Modular Cleanroom Ceiling Grid
  • Cleanroom Conversion Wall Treatment Cleanroom Conversion: FRP and CPVC Panels
  • Office Space Converted to an ISO 7 Cleanroom Cleanroom Conversion Panels
Modular Cleanroom Ceiling Grid
Cleanroom Conversion Wall Treatment
Office Space Converted to an ISO 7 Cleanroom

Technical Resources

Converting an Office or Lab into a ISO 5, ISO 6, ISO 7 or ISO 8 Cleanroom

Facility managers who need classified cleanroom space generally face a difficult choice.

New construction requires a suitable site and can take months, even years, to complete. Depending on area requirements, installing a modular cleanroom inside an existing room is a faster, more economical alternative, but this room-within-a-room approach often creates unusable or inaccessible space.

Terra’s BioSafe Cleanroom Conversion System offers a more economical, space-efficient approach: converting an existing unclassified room into a cleanroom, using modular components to meet a wide range of environmental and access requirements.

Modular Ceiling Grid

This modular structure mounts directly to existing walls to form a drop ceiling, or rests on top of walls that have no ceiling. Its all-steel, interlocking design requires no external bracing (either column support or suspension cables) for spans up to 20 ft. (6096 mm). Larger spans entail a single internal support column or external ceiling support cable.

The grid's 2-foot x 4-foot (610 x 1220 mm) ceiling bays support cleanroom ceiling components: room-side replaceable HEPA fan/filter units (FFUs), LED or fluorescent lights, and polypropylene ceiling panels.

Terra’s WhisperFlow™ Room-Side Replaceable FFUs provide the vertical flow of micro-filtered air that removes contaminants inside the room. By selecting the proper quantity of FFUs, you can meet any cleanliness classification to ISO 5 (Class 100). Their design allows filter replacement from inside the cleanroom, without breaching the cleanroom ceiling. Lights and blank ceiling panels complete the ceiling structure. See additional information below.

BioSafe® Cleanroom Wall Systems

Our Class A fiberglass-reinforced plastic (FRP) panel system is the only one that is certified for use in ISO 5 cleanrooms. Applied with a non-outgassing polymer adhesive to nearly any wall surface, including gypsum wallboard, this material features a patented finish that creates a durable, noncontaminating surface that is highly resistant to chemicals and microbial growth. More economical Class C panel are available (see ordering information).

CPVC (chlorinated polyvinyl chloride) Class A wall panels also meet ISO 5 requirements. A solvent-free, non-outgassing adhesive adheres them to walls. Seams are welded to close all gaps and make this system a great choice for converting current building space into a cleanroom. CPVC resists damage from a broad range of chemicals, making clean-up faster and easier.

The links below provide more information on these and other components that comprise this system, including cleanroom doors, pass-through chambers, and flooring. Installation of smooth Class A BioSafe panels, with proper wall and ceiling coving, meets stringent ISO 5-6 and cGMP requirements for the most critical applications, including sterile processing. For less critical cleanroom requirements, consider FRP Class C panels.

Complete Pre-Sale and After-Sale Support

Whatever your applications, call Terra with your dimensional, cleanliness and other requirements. A configuration specialist will provide a complete quotation, including drawings, if applicable, and manufacturing time, on a system ready for installation and certification.

Terra performs BioSafe system installation and seismic analysis based on your facility. We also train and support local contractors on installation and permitting to local building code.*

Hide
You need at least 2 products to compare Compare Clear All
Compare Products