1. Uniform, HEPA-filtered airflow protects the work area from airborne hazards, such as particles or microorganisms; choose from vertical and horizontal flow

    288 Products

    288 Products

  2. Contaminated air can be vented to an outside exhaust system or purified by passing through carbon/HEPA filtration for indoor release (ducted vs ductless)

    351 Products

    351 Products

  3. Hoods designed for both clean processing and containment of the exhaust air; includes Class I and II, Types A and B, and a unique Type C from Labconco

    66 Products

    66 Products

  4. Replacement parts and accessories, including filters, for laminar flow hoods, fume hoods and biosafety cabinets

    641 Products

    641 Products

4 Item(s)

Features and Benefits

UV Germicidal Lamp

The V-Ray germicidal UV lamp is installed within a Terra hood to inhibit microbial growth on the work surface

Bag-In/Bag-Out HEPA Filter Replacement

The bag-in/bag-out HEPA filter replacement system allows trained personnel to safely remove the dirty filters without risking exposure to harmful contaminants.

UV Light Cycle Timer

Operators can set the timer for durations of 5, 10, 15, 30, 60, 120 and 240 minutes or continuous. Upon activation, the timer automatically shows the previous setting, but the operator can easily change the time setting.

Smart-Flow™ Airflow Monitor

The LCD display shows the equipped filter types, the status of the filters, and airflow face velocity. On/off buttons are provided to toggle the blower and light fixture. All settings are programmable and can be electronically locked for security.

Chem-Zone Work Surface

The dished Chem-Zone™ Work Surface contains spills and features perimeter air-inlets that lead directly to the exhaust filter. Air captured within this zone will never be recirculated inside the hood, preventing the buildup of hazardous fumes.

Air Return Ducts

For enhanced air-stream control, the flow station features return ducts along the edges of the hood opening. These ducts reduce backwash caused by placing objects near the work surface edge, a common source of turbulence inside a clean bench.

Status Indicator Light

The Terra Universal logo incorporates an LED light that functions as a status indicator. The TUI logo will flash when the unit is connected to power, but the blower is switched off. A solid glow indicates the station is fully operational.

Counterweighted, Anti-Racking Sash

The sash is angled at 10° for improved ergonomics without introducing glare. During operation, an alarm will be activated if the sash is opened too far, compromising airflow.

Inclined, Ergonomic Inlet Grille

The curved inlet grille provides comfortable support for the operator’s forearms while working within the hood. The airflow inlet pattern is designed to compensate for any airflow restrictions caused by the operator blocking the slots.

Static-Dissipative PVC Sliding Shield, Side Panels

Sliding shield and side panels made of transparent, chemically resistant static-dissipative PVC help contain fumes and protect operator from spills (select preferred work surface and vapor sealed or explosion-proof light separately).

Exhaust Duct Connection

10"-diameter flange allows connection to remote ventilation system for fume removal (explosion-proof ductless models with exhaust fans available).

Touchscreen Control Panel

PLC control panel provides control of fan speed, lights, and motorized shield; digital gauge monitors backpressure and issues alerts when filter(s) need replacement

Easy Clean Seamless Tracks

Removable panel design provides easy access to all hood surfaces

HEPA-Filtered Reverse Flow Fan Unit

High Efficiency Particulate Air (HEPA) Filter Fan Unit provides clean micro-filtered air, shown in reverse-flow hood that captures contaminants generated in the work area for safe cleanroom release.

Recessed LED Lighting (WhisperFlow® Hoods)

The WhisperFlow® line of laminar flow hoods include LED lighting as standard, positioned behind the sash to prevent glare.

Labconco Protector Echo – Access Card Reader

Labconco’s Protector Echo Series features enhanced safety protocols, including an RFID card system for controlling access to the hood.

Hoods & Biosafety Cabinets

  • Labconco’s Ergonomic, ADA-Compliant Hood Design Labconco’s Ergonomic, ADA-Compliant Hood Design
  • Vertical Laminar Flow Tilt-Up Shield Tilt-Up Shield
  • High-Clearance, Wide-Access Vertical Laminar Flow Hoods ValuLine™ Vertical Laminar Flow Stations
  • PLC Touchscreen Controls on Vertical Laminar Flow Hood PLC Touchscreen Panel on Vertical Laminar Flow Hood
  • Labconco Protector ClassMate Labconco Protector ClassMate
  • Labconco Xpert Balance Enclosure – 8 ft Labconco Xpert Balance Enclosure – 8 ft
  • Labconco Xpert Nano Ductless Exhaust Hood Labconco Xpert Nano Ductless Exhaust Hood
  • PCR Workstation PCR Workstation
  • Benchtop Ductless Fume Hood Benchtop Ductless Fume Hood
  • Labconco Protector XL Labconco Protector XL
  • Labconco Protector XVS Ventilation Stations Labconco Protector XVS Ventilation Stations
  • Labconco Protector® Echo – Floor Mounted Labconco Protector® Echo – Floor Mounted
  • Exploson-Proof Ductless Fume Hood in Use Powder-Coated Explosion-Proof Ductless Fume Hood
  • Static-Dissipative Benchtop Vertical Laminar Low Hood, Shown in Use WhisperFlow® Hood
  • Vertical Laminar Flow Station with Vibration Isolated Work Surface Isolated Work Surface Enhances High Magnification Viewing
  • Protector XStream Laboratory Fume Hoods by Labconco
  • Horizontal Laminar Flow Hood In Use Horizontal Laminar Flow Station
  • Hoods
  • Hoods
  • Hoods
  • Hoods
  • Hoods
Labconco’s Ergonomic, ADA-Compliant Hood Design
Vertical Laminar Flow Tilt-Up Shield
High-Clearance, Wide-Access Vertical Laminar Flow Hoods
PLC Touchscreen Controls on Vertical Laminar Flow Hood
Labconco Protector ClassMate
Labconco Xpert Balance Enclosure – 8 ft
Labconco Xpert Nano Ductless Exhaust Hood
PCR Workstation
Benchtop Ductless Fume Hood
Labconco Protector XL
Labconco Protector XVS Ventilation Stations
Labconco Protector® Echo – Floor Mounted
Exploson-Proof Ductless Fume Hood in Use
Static-Dissipative Benchtop Vertical Laminar Low Hood, Shown in Use
Vertical Laminar Flow Station with Vibration Isolated Work Surface
Horizontal Laminar Flow Hood In Use



Can't find what you're looking for?
Tell us what you need and we'll build it!



SUBMIT A QUICKQUOTE REQUEST


Need Help?

(714) 578-6100

EMAIL CHAT

Mon - Fri, 5:30am - 5:30pm PST

Hide
You need at least 2 products to compare Compare Clear All
Compare Products