Select Product
Detection Wavelength

Detection Modes

Slide Capacity

Manufacturer SKU

Terra Part #PriceShips in
2532Fluorescent1 Slide710 3031-33 61282 $58,66215-19 Days2
2532Fluorescent24710 3031-33-AL 61284 $96,37315-19 Days3
2670Fluorescent1 Slide710 3031-33-IR 61283 $63,69015-19 Days4
2670Fluorescent24710 3031-33-IRAL 61285 $101,40115-19 Days5
Detection Channels
Detection Wavelength
Detection Modes
Slide Capacity
Manufacturer SKU
Item ordered before. Click on bagde to see the order.

Up to 30-day trial periods, free return shipping and on-site training available for qualified equipment.

Request demo from your product specialist or add note to your order or quote request.

Some ship in:
Usually Ships in:
Free shipping in contiguous USA
Custom-configured product. Contact Terra by phone, chat or email for a project-specific quote.
Custom-configured product. Contact Terra by phone, chat or email for a project-specific quote.
Select a product line for product summary
Product Details
  • InnoScan 710 2-Color Fluorescence Microarray Scanners available in standard, infrared (IR) and autoloader combination models
  • Compact and portable units accommodate a host of fluorescent dyes and feature dynamic auto-focusing for unparalleled reduction in signal-to-noise ratio
  • Performs batch processing, barcode scanning and automatic spot flagging ideal for clinical and diagnostic applications
  • Autoloader models 710AL and 710IRAL (with infrared detection) models provide high-resolution, high-speed fluorescence scanning of all standard glass microarrays
  • Infrared models 710IR and 710IRAL detect 670 nm (cyanine 5.5) and 785 nm (infrared dye)
  • Dynamic auto-focusing features increases signal intensity, adjustment to temperature changes, mechanical perturbation and reduces background noise
  • Proprietary rotary scanning architecture allows the fastest scanning speeds, reduces vibrational noise and increases image quality
  • Scans entire 25 x 76 mm substrate slide in 3 minutes
  • High resolution acquisition system: scans spot sizes down to 30 µm diameter
  • Adjustable scan resolution from 3 µm to 40 µm
  • Ideal for both in situ and ex situ microarrays
  • 710 and 710AL models detect 532 nm (cyanine 3) and 635 nm (cyanine 5)
  • Compatible IR dyes: IRDye 800 RS (Li-Cor), DyLight 800 (Pierce) and Alexa Fluor 790 (Invitrogen)
  • Compatible with: Arrayit microarrays and major brands of open platform microarray products
  • Applications: clinical and diagnostic applications
  • Includes: Mapix software(data acquisition and image analysis software), automatic spot recognition, powerful image analysis, computer and monitor, and complimentary software upgrades for one year
Features & Benefits

Features and Benefits

Learn More: InnoScan 710

More Information

Mapix Software Features:
  • High-quality data ensured by automatic spot segmentation; selects only relevant pixels
  • Process of gridding performance and quantification adapted to the high resolution of the InnoScan 710 and to the size of generated images
  • Highly interactive commands fully correlate between displayed data, pictures and plots for optimal data visualization
  • Compatible with all types of microarrays built for ex-situ and in-situ techniques
  • Reads and analyzes, interstitial/staggered/orange packing patterned microarrays made by Protein NanoPrint, Agilent and others
  • Boosts productivity with batch processing for analysis of large number of microarrays per day (available in Version 3.0.0)
  • Free online software updates for the first year
Configurable for full or modular automation of:
  • Scanner control
  • Configuration saving (scan and analysis parameters)
  • Bar code reading
  • Quality control by flagging
Compatible with all industry-standard formats and platforms:
  • Supports GAL files and recordable transcripts in text and GPR formats
  • Saves images as 16-bit TIFF files with all read parameters that can be copied in JPEG format
  • Supports image analysis of 16-bit TIFF files using other scanners [anchor link to Microarray Scanners sub-landing when it’s created]
  • Runs on all operating systems such as: Windows, 32- and 64-bit Linux and Macintosh
Model#710#710IR#710AL#710IRAL
Excitation wavelengths532 nm and 635 nm670 nm and 785 nm532 nm and 635 nm670 nm and 785 nm
DetectionCy3, Alexa 3, Alexa 546, Alexa 555, Cy5, Alexa
5, Alexa 647, and Alexa 660
Cy5.5 and infrared 785 nm dyesCy3, Alexa 3, Alexa 546, Alexa 555, Cy5, Alexa 5, Alexa 647, and Alexa 660Cy5.5 and infrared 785 nm dyes
Autoloader capacityNo autoloaderNo autoloader24 standard 25 x 76 mm glass substrate slides24 standard 25 x 76 mm glass substrate slides
Autoloader speedNo autoloaderNo autoloader5 seconds load/unload per substrate slide5 seconds load/unload per substrate slide
Autoloader throughputNo autoloaderNo autoloader100 min for 24 substrate slides100 min for 24 substrate slides
Unit Dimensions
W x D x H in. (mm)
11.02 x 18.11 x 14.56
(280 x 460 x 370)
11.02 x 18.11 x 14.56
(280 x 460 x 370)
12.99 x 23.62 x 16.53
(330 x 600 x 420)
12.99 x 23.62 x 16.53
(330 x 600 x 420)
LasersThermoelectrically cooled laser diodes with stabilized feedback output
Optical resolution3 µm
Pixel size3 µm to 40 µm
Laser powerAdjustable (2 laser power settings available)
Gain PMTLinear from 0 to 100%
AutofocusReal-time and automated
DetectionTrue confocal and high performances digital laser/PMT system
Scanning time3.5 min per 22 x 74 mm substrate at 10 µm resolution
Scan areaFull substrate slide area (22 x 74 mm)
Image formatStandard TIFF (16 bit grayscale)
Barcode readerAll formats
Power supply88 – 264 VAC
ClassClass I laser product
Sensitivity0.05 fluor/µm²
Dynamic range>10,000-fold
ClassClass I laser product
Sensitivity0.05 fluor/µm²
Dynamic range>10,000 fold
Uniformity<5% CV
FormatOpen platform glass substrate slides 0.98 x 2.99 in. (25 x 76 mm)
Computer interfaceEthernet
Image analysisHighly accurate grid positioning using automatic spot recognition for
accurate quantification and 16 bit exportable TIFF data
Compatible fluorophores
  • Cy5.5 (685 nm)
  • Cy5
  • Cy3
  • Alexa 647
  • Alexa 660 (635 nm)
  • Alexa 546
  • Alexa 555 (532 nm)
  • 785 nm infrared dyes
  • custom wavelengths
  • available
Additional features
  • Affordable high sensitivity system with low background noise and low maintenance
  • Real-time image acquisition for all microarray types such as in-situ high density glass slide microarrays, spotted microarrays, tissue and cell microarrays
  • Software for OS environments (Linux, Windows)
  • Ethernet interface for data sharing (several users can share scanner over network)
  • Uniform scanning on entire microarray surfaces and substrate types (plastic, membrane and glass)
  • Compact, portable units not sensitive to shocks, vibration and slide deformation
  • Much greater reliability and longevity than conventional raster scanners

InnoScan Auto-Focusing for Uniform Microarray Scanning

Arrayit InnoScan 710 Microarray Scanners scan the entire substrate surface uniformily. eilimnates disruption in fluorescent emission caused by temperature changes

Arrayit InnoScan 710 Mapix Software

Arrayit InnoScan 710 Fluorescence Microarray Scanners include Mapix Data Acquisition Software with automatic spot searching and slide grid alignment
Products similar to this one
Other products you may find relevant
Buy Accessories

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.

Hide