FREE CONSULTATION714-578-6100
  1. Home
  2. Laminar Flow Hoods, Fume Hoods, Biosafety Cabinets
  3. Ductless Exhaust Hoods
  4. Protector Echo Floor-Mounted Filtered Fume Hoods

Protector Echo®Floor-Mounted Filtered Fume Hoods
by Labconco

GFH Filtration Technology and Neutrodine Filters
Ductless hoods with a 63.6” loading height
for large, bulky equipment that emil noxious fumes
Energy efficient Protector Echo Floor-Mounted Filtered Fume Hoods have the interior height to accommodate lab carts and other large, bulky equipment.  Labconco’s Protector Containment design and Erlab's innovative GreenFumeHood® (GFH) Filtration Technology provide built-in safety features that require minimal operator intervention. 

Protector-Echo Floor-Mounted Filtered Fume Hood Video

This video gives an overview of features and benefits of the Protector-Echo Filtered Fume Hood along with a list of compatible and incompatible chemicals that have been tested with Neutrodine filtration. A brief installation overview and maintenance requirements are also covered as well as an Energy Savings Evaluation.



Ordering Information

4' Protector Echo Benchtop Filtered Fume Hoods, 115V

Labconco
Part #
Exterior
Depth
Service
Fixtures
Electrical
Duplexes
Cat. # Price
183410000 37.7" (958 mm) No No 1535-10 Price
183410002 37.7" (958 mm) 2 1 1535-11 Price
183420000 43.7" (1110 mm) No No 1535-12 Price
183420002 43.7" (1110 mm) 2 1 1535-14 Price
183430000 55.7" (1415 mm) No No 1535-15 Price
183430002 55.7" (1415 mm) 2 1 1535-16 Price
See 5’, 6’ and 8’ models
*Contact a Terra Sales Engineer for pricing details and customized numbers of service fixtures or duplexes
See Required Neutrodine Filters and Optional Accessories

5' Protector Echo Floor-Mounted Filtered Fume Hoods, 115V

Labconco
Part #
Exterior
Depth
Service
Fixtures
Electrical
Duplexes
Cat. # Price
183510000 37.7" (958 mm) No No 1535-17 Price
183510002 37.7" (958 mm) 2 1 1535-18 Price
183520000 43.7" (1110 mm) No No 1535-19 Price
183520002 43.7" (1110 mm) 2 1 1535-20 Price
183530000 55.7" (1415 mm) No No 1535-21 Price
183530002 55.7" (1415 mm) 2 1 1535-22 Price
See 4’6’ and 8’ models
*Contact a Terra Sales Engineer for pricing details and customized numbers of service fixtures or duplexes
See Required Neutrodine Filters and Optional Accessories

6' Protector Echo Floor-Mounted Filtered Fume Hoods, 115V

Labconco
Part #
Exterior
Depth
Service
Fixtures
Electrical
Duplexes
Cat. # Price
183610000 37.7" (958 mm) No No 1535-23 Price
183610002 37.7" (958 mm) 2 1 1535-24 Price
183620000 43.7" (1110 mm) No No 1535-25 Price
183620002 43.7" (1110 mm) 2 1 1535-26 Price
183630000 55.7" (1415 mm) No No 1535-27 Price
183630002 55.7" (1415 mm) 2 1 1535-28 Price
See 4’, 5’ and 8’ models
*Contact a Terra Sales Engineer for pricing details and customized numbers of service fixtures or duplexes
See Required Neutrodine Filters and Optional Accessories

8' Protector Echo Floor-Mounted Filtered Fume Hoods, 115V

Labconco
Part #
Exterior
Depth
Service
Fixtures
Electrical
Duplexes
Cat. # Price
183810000 37.7" (958 mm) No No 1535-29 Price
183810002 37.7" (958 mm) 2 1 1535-30 Price
183820000 43.7" (1110 mm) No No 1535-31 Price
183820002 43.7" (1110 mm) 2 1 1535-32 Price
183830000 55.7" (1415 mm) No No 1535-33 Price
183830002 55.7" (1415 mm) 2 1 1535-34 Price
See 4’, 5’ and 6’ models
*Contact a Terra Sales Engineer for pricing details and customized numbers of service fixtures or duplexes
See Required Neutrodine Filters and Optional Accessories



Additional Features and Specifications

  4’ Model 5’ Model 6’ Model 8’ Model
Roughing Prefilter 2 3 4 5
Built-in Exhaust Fans 2 3 4 5
Conformance/Certification SEFA 9-2010, DHIII, SEFA 8-2010, Cabinet Surface Finish Tests, ASHRAE 110-95, ANSI Z9.5-2011, AFNOR NF X 15-211, ASTM E84-09C, UL 61010-1, CAN/CSA C22.2 No. 61010.1
  • Two tempered safety glass vertical-rising sashes with powder coated aluminum sash handles and powder-coated steel sash tracks with Clean-Sweep™ slots
  • Upper sash handle also includes Clean-Sweep™ openings
  • Sash stops at 52” from floor; 63.6" loading height, 73.5” high sightline from floor to header panel
  • Removable Opti-Zone Baffles; removable front and side panels, and front and interior service access panels
  • Pre-wired vapor-proof fluorescent lighting and audio visual alarms
  • Multi-layer design of revolving filtration system of Neutrodine carbon filters reduce maintenance cost and provides maximum safety in the simultaneous handling of solvents, acids, bases, ammonia and formaldehyde
  • Radio frequency identification (RFID) cards prevents unauthorized personnel from operating hood
  • Factory-installed control panel with digital display, fan button and light button
  • Factory-prepared for up to four electrical duplex receptacles and eight service fixtures
  • Built-in exhaust fans maintain 60 fpm face velocity at 16" sash opening height
  • Sensor package for primary filter breakthrough of solvent and acid fumes, laboratory air quality, sash position, and temperature
  • Sound pressure of <60 dB(A) with sash at operating height and <48 dB(A) with sash closed
  • Power cord with plug or hard wired to top-mounted boxes

Top of Page

Required Accessories for Protector Echo Floor-Mounted Filtered Fume Hoods

Neutrodine Filter Chart

Labconco Part # Description Cat# Price
9577400 Neutrodine Molecular Filter (see chart for required quantity) 3652-88 Price
filter chart
Neutrodine Hood Revolving Filter System
Neutrodine Filter

Neutrodine filters are carbon filters that utilize multiple layers of technology to transform molecules, allowing the simultaneous adsorption of solvents, acids, bases, ammonia and formaldehyde. Each filter is designed with a unique filter frame that prevents carbon shifting and channeling, which significantly extends the lifetime of the filter. The high retention capacity of Neutrodine filters provide an unprecedented level of safety and savings. Testing results found Neutrodine filters very efficient when tested on over 500 chemicals with six or more concentrations.

Top of Page

Optional Accessories for Protector Echo Floor-Mounted Hoods


HEPA Filters and Replacement Parts
Labconco Part # Description Cat# Price
9577401 HEPA Filter, 99.995% efficient (optional) 3652-89 Price
9577402 Replacement Roughing Prefilter 3652-90 Price
9577403 Replacement Acid Sensor, Required every two years 3652-91 Price
9577700 Replacement light bulb 3652-92 Price
gGuard Communication Software
Labconco Part # Description Cat# Price
958110 gGuard Communication Software 3652-93 Price
Automatically collects and records hood data, alerts and alarms on a customer-supplied personal computer. Monitors, manages and provides data via email to a designated facility manager. Provides access to the following: usage authorization, filter usage, Neutrodine Filter saturation detection, filter identification, sash position, blower speed, laboratory air pollution detection, temperature and usage statistics.
ADA Compliant Remote Control
Labconco Part # Description Cat# Price
9579700 ADA Remote Control 3652-94 Price
Wireless remote control allows persons in wheelchairs and/or shorter individuals to access the fan and light switches.
Sash Opening Reduction Wing Kit
Labconco Part # For Use With Sash Opening Cat# Price
9584904 4' Protector Echo 18" x 16" 3652-96 Price
9584905 5' Protector Echo 26" x 16" 3652-97 Price
9584906 6' Protector Echo 34" x 16" 3652-98 Price
9584908 8' Protector Echo 48" x 16" 3652-96 Price
Wings reduce the sash opening area to increase face velocity at the 16" sash stop position from 60 fpm to 100 fpm.

Benefits of GFH Filtration Technology for Protector Echo Benchtop

Benefits of GFH Filtration Technology
  Erlab's GFH Filtration Technology provides safety and performs well beyond SEFA 9-2010 DH III definition requirements. The built-in features of the Protector Echo maintain user safety by constantly monitoring and preventing unsafe conditions. 

Safety features:

  • Controls access via radio frequency identification (RFID) cards
  • Audio/visual alarms alerts of filter breakthrough, fan failure, high sash position and high temperature
  • Intelligent filter indication of type and status (primary or secondary)
  • Prevents saturated filter re-installation with RFID technology scanning each filter’s serial number
  • Optional gGuard® communication software for real time monitoring by a designated facility manager from a remote location
Top of Page

Similar Products

Click on the blue bar at the bottom of the page and speak with a Product Specialist for pricing and a free quote. 

24-hour sales and tech phone support, M - F
Go to...
Go To
Laboratory-Equipment.com