FREE CONSULTATION714-578-6100
  1. Home
  2. Laminar Flow Hoods, Fume Hoods, Biosafety Cabinets
  3. Laminar Flow: Clean Benches & Portable Hoods
  4. Portable CleanBooth™
WhisperFlow

Portable CleanBooth™

Horizontal Laminar Flow
Model shown: 1870-02 with optional FFU, "A"-base bench, and curtains.
 
Features Key
  Standard
  Option

A Powder-coated steel frame securely positions fan/filter module above workstation
B Select HEPA or ULPA fan/filter modules to provide a laminar flow of clean air
C Fluorescent light available
D Flexible side- and rear-panel kit encloses work area, optimizes laminar flow
E Ionizing bar neutralizes surface charges to prevent electrostatic discharge
F Casters enhance portability
G Variety of work surfaces available – 2-piece design isolates blower vibration
H Modular Drawers – select stainless steel or plastic
I Steel-reinforced nylon levelers resist most chemicals
J Power switch for blower, light and other electrical modules


  • Castered frame positions Fan/Filter Unit (FFU) above benchtop or large process equipment for repair operations wherever you need a temporary laminar flow of filtered air
  • Internal baffling plates and anodized aluminum diffuser panel ensure uniform air speed across the work area
  • Quiet operation: 50 dBA measured 30" (762 mm) from filter face
  • Flexible side panels create a 3-sided enclosure, enhancing the laminar flow
  • Available with a variety of work surfaces to meet your requirements
Mobile Frame Support
Includes set of 4 casters, 2 with locking brakes. Order Fan/Filter Units separately.
Frame Dimensions
W x D, nominal
Inches (mm)
No. of FFUs required;
order below
Inches (mm)
Fixed Height
Cat.# Price
53 x 30 (1346 x 762) 1 24 x 48 (610 x 1219) 1870-01 Price
76 x 30 (1930 x 762) 2 24 x 36 (610 x 914) 1870-02 Price
53 x 53 (1346 x 1346) 1 48 x 48 (1219 x 1219) 1870-03 Price

Order Side Panels, Fan Filter Units, Work Benches and accessories below.

Frame support 1870-03 shown with optional 4'x4' fan/filter unit and softwall-panel kit 1330-08. Order table separately.

Terra's Portable CleanBooth™ provides a mobile, versatile mini-cleanroom wherever you need it! It is ideal for operations with probe stations, screen printers and other free-standing process equipment, as well as benchtop kitting or assembly.

FFU: Quiet, Reliable Operation

It consists of two modules: a fan/filter unit (FFU), which houses a particle filter, and a mobile support frame. The 2' x 3', 2' x 4' or 4' x 4' FFUs house a HEPA filter, rated 99.99% efficient with 0.3 micron particles. Fan/filter units come with brushless AC motors or low-energy EC (electrically-commutated) motors that comply with energy-efficiency standards. The lightweight design of Terra's FFUs make them ideal for mounting either to the mobile frame or to any standard 2' x 4' (610 mm x 1219 mm) ceiling grid. An internal baffle system ensures uniform face velocity, and the 50 dBA noise rating is the best in the industry.

Fan/filter units add 13 inches to the overall height of portable CleanBooths.

Mobile Frame Support

The FFU is attached to a castered support frame for easy positioning at locations throughout your facility.

Fabricated of 1" x 2" (25 mm x 51 mm) square steel powder-coated members, it positions the filter face 70"(1778 mm) or 83" (2108 mm) above the floor. The nonmarking castered wheels lock in place to keep the station where you need it. Its sturdy construction safely supports the FFU with minimal vibration. And because the frame does not come in contact with the bench top or service equipment, the blower vibration is effectively isolated from the work-in-progress.

Flexible Side Panels Restrict Air Flow to Optimize Cleanliness
For enhanced laminar flows, select the optional side panels, available in three materials:

Cleanroom-Grade Vinyl is fire retardant and low outgassing.

Static-Dissipative Vinyl is manufactured with permanent built-in static inhibitors that, unlike topical treatments, will not wear off.

Non-outgassing Polyurethane is made from inherently static-dissipative polyurethane that provides permanent, humidity-independent ESD protection for sensitive manufacturing conditions. Polysim contains no plasticizer, making it virtually non-outgassing.

Side softwall panels attach to the FFU by means of a unique, noncontaminating Grip-Track™ mounting system that eliminates cracks and seams where germs or particles can collect.


Side Softwall Panel Kits
Includes curtains of specified material that attach to the FFU. Kit catalog number includes installation of Grip-Track mount on two sides and rear of FFU. Panels can be cut to bench level.

For Cleanbooth
in. (mm)
Cleanroom Vinyl Anti-Static Vinyl Polyurethane
Cat.# Price Cat.# Price Cat.# Price
49 W x 60 H (1245 x 1524) 1330-00A Price 1330-01A Price 1330-02 Price
77 W x 60 H (1956 x 1524) 1330-05A Price 1330-06A Price 1330-07 Price
49 W x 73 H (1245 x 1854) 1330-08 Price 1330-09 Price 1330-10 Price

Fan/Filter Unit (FFU)
Includes HEPA filter rated 99.99% efficient @ 0.3 µm particles. Avg. flow of 2' x 4' FFU or 2' x 3' FFU @ 90 FPM (0.46 m/s): 650 CFM (1104.36 m³/h). The 4' x 4' FFU has a minimum airflow of 650 CFM. See ordering chart for required quantity. Fan/filter units with ULPA filters and low-energy, direct-current (DC) motors are available; speak with a Terra Product Specialist for details.

Dimensions
(nominal)
24" x 48"
(610 mm x 1219 mm)
24" x 36"
(610 mm x 914 mm)
48" x 48"
(1219 mm x 1219 mm)
Cat.# Price Cat.# Price Cat.# Price
110VAC, 60Hz 6601-24-H $ 677 6601-23-H $ 677 6601-44-H $ 1,549
220VAC, 50/60Hz 6601-24-H-220 $ 787 6601-23-H-220 $ 787 6601-44-H-220 $ 1,475

Ionizing Bar
Includes ionizing bar, power supply, and installation kit; Ionizing kit and FFU must be ordered together.

IonBar ™ with Installation Kit
For use with
FFU sizes below
110 VAC 220 VAC
Cat. # Price Cat. # Price
2' x 3' 2005-48 Price 2005-48-220 Price
2' x 4' or 4' x 4' 2005-49 Price 2005-49-220 Price

Fluorescent Light

Dimensions
nominal
in. (mm)
115/227VAC, 50/60Hz
Cat.# Price
35.5 long (1) (902) 1870-10 Price
47 long (2) (1194) 1870-11 Price
(1) Two required for 73" (1854 mm) -wide Cleanbooth. Includes Installation.
(2) One required for 49" (1524 mm) -wide Cleanbooth. Includes Installation.

Work Benches

These benches have adjustable legs for work-surface heights of 25" to 34" above the floor. Several surface materials are available to meet specific applications. The epoxy-finished steel frame includes a stainless steel scuff guard on the lower leg member to prevent scratching and chipping.
Work Benches (A-base design)
Bench Top
Dimensions
W" x D"
(mm)
Nonconductive Laminate Conductive Laminate Polypropylene
With Raised Lip
304 Stainless Steel-
Solid
304 Stainless Steel-
Perforated
Cat. # Price Cat. # Price Cat. # Price Cat. # Price Cat. # Price
48 x 30
(1219 x 762)
1722-00 $ 634 1728-00 Price 1522-00 Price 1521-45 $ 1,221 1522-56 Price
72 x 30
(1829 x 762)
1726-00 $ 693 1732-00 Price 1522-02 $ 869 1752-00 Price 1522-58 Price

File Type File Name Publication Date
White Paper (PDF) Vertical vs Horizontal Laminar Flow
Things to consider when deciding between vertical or horizontal flow. There are advantages and disadvantages to each airflow direction and hood design, depending on your application and laboratory lay-out.
05/28/2015
White Paper (PDF) Airflow Uniformity and Fan Filter Units
Fan filter units help to remove contaminants from controlled environments. They are effective if designed well. Variables like speed and baffles contribute to an FFU's ability to maintain uniform air speed and direction. Read more about how FFUs help you comply with ISO and other regulations.
05/28/2015
Manual (PDF) CleanBooth Laminar Flow Station: Doc. # 1800-73
10/06/2010
Manual (PDF) Ionizing Equipment (Ion Bar): Doc. # 1800-45
Quick-Start Operating Guide for Terra's IonBar Ionizing Bar, creating a balanced stream of positive and negative ions to combat ESD in your work station.
10/06/2010
Click to leave a message. 24-hour sales and tech phone support, M - F
Go to...
Go To
Laboratory-Equipment.com