55172
Pass-Through; CleanSeam™, 36" W x 36" D x 24" H ID, Standard Wall Mount, 316L Stainless Steel
Product Details
  • Available ISO Ratings: ISO 6, ISO 7, ISO 8
  • Automatic mechanical door interlock minimizes contamination exposure as materials are transferred
  • Interlock automatically engages when operator pulls LiftLatch to open pass-through door
  • Unique design features rounded corners with no cracks; ideal for strict sterilizing protocol
  • Included chrome-plated LiftLatches don't strain hinges
  • Static-dissipative PVC windows protects against static charges and particle attraction
  • Includes two sets of steel mounting brackets and automatic mechanical interlock
  • Standard bracket mounting is 2" (51 mm) from the front on the cleanroom side
  • Brackets require 0.25" (6 mm) clearance between the wall cut-out and the pass-through
  • Optional upgrade: to prevent users on both sides from forcefully pulling the doors open at the same time and risking damage, Smart CleanMount Pass-Throughs offer visual red/green status lights to notify users when a door can be opened safely.
  • To avoid manufacturing delays, please approve system drawings promptly
  • Continuous-seam, smooth-ground welds eliminate germ and particle traps, simplify cleaning and sterilizing
  • Custom sizing and electrical add-ons, such as UV lights or temperature control, invalidate UL listing

Inside Depth: 36"

Inside Height: 24"

Inside Width: 36"

Material: 316L Stainless Steel

Model: CleanSeam™

Mounting Position: Standard Wall

Opening Dimensions: 34"W x 22"H

Window Material: SD-PVC

Unit of Measure: EA

Dimensions, Product: 39" W x 40" D x 27" H

Dimensions, Shipping: 43" W x 41" D x 31" H

Marks & Listings: CE, UL, ULC

Package Type: Crate

Weight, Product: 140.62 lb

Weight, Shipping: 185 lb

Manuals & Resources
Buy Accessories
  1. Stainless steel support brackets are recommended for pass-throughs deeper than 24"  |  1993-60C displayed
    $558
    Increase Down Increase Up
  2. Racks shown mounted in pass through. Shelf sold separately.  |  1993-40A displayed
    $975
    Increase Down Increase Up
  3. Small (4") locking latch, catcher included. Grid shows one-inch squares.  |  1603-80 displayed
    $107
    Increase Down Increase Up
  4. Shown on reference grid of 1-inch (25mm) squares  |  1603-40-2-316 displayed
    $370
    Increase Down Increase Up
  5. Removes solvents and other hazardous vapors from materials while they are in the pass-through  |  6705-23 displayed
    $510
    Increase Down Increase Up
  6. Service, ISO 6 Rating Declaration
    Request Quote
    Increase Down Increase Up
  7. Warranty; 2 Year, Pass-Throughs, Parts
    Request Quote
    Increase Down Increase Up
  8. Warranty; 3 Year, Pass-Throughs, Parts
    Request Quote
    Increase Down Increase Up
  9. FasTrak 24-7 Expediting Service
    Request Quote
    Increase Down Increase Up
  10. Electropolish Service
    Request Quote
    Increase Down Increase Up
  11. White Glove Freight Service
    Request Quote
    Increase Down Increase Up
  12. Equipment Testing
    Request Quote
    Increase Down Increase Up
  13. Qualification Documentation (IQ/OQ) for Terra Universal System
    Request Quote
    Increase Down Increase Up
  14. UL Listing Declaration for Leak-Rated Pass-Throughs
    Request Quote
    Increase Down Increase Up

CleanSeam™ Pass-Through Chambers

  • Cleanroom Pass-Through Chamber Video Overview Cleanroom Pass-Through Features and Selection Guide
  • CleanSeam™ Cleanroom Pass-Through Chamber CleanSeam™ Pass-Through Chambers
  • Double stacked stainless steel cleanroom pass-through chambers Double Stacked Stainless Steel CleanSeam Pass-Through Chambers
  • Stainless steel hospital pass-through for primary, secondary, tertiary services Stainless Steel Hospital Pass-Through for Primary, Secondary, Tertiary Services
  • Stainless Steel Cleanroom Pass-Through with Cart Ramps Floor-Mount CleanSeam™ Pass-Through, 36''W x 36''D x 48''H, with Cart Ramps
  • Stainless Steel Floor-Mount Pass-Through Chamber, 24''W x 24''D x 36''H, with Cart Ramp Floor-Mount CleanSeam™ Pass-Through, 24''W x 24''D x 36''H, with Cart Ramp
  • Cleanroom Pass-Through Chamber with Door Open CleanSeam™ Pass-Through Chamber, 18"W x 18"D x 18"H
Cleanroom Pass-Through Chamber Video Overview

Features and Benefits

Learn More: CleanSeam Dimensions

CleanSeam Pass-Through Chamber

Don't risk operational delays or cleanroom shutdown because of a damaged door!
Terra's pass-through chambers last indefinitely, much longer than our standard product revision cycle. Pass-Through doors, however, are subject to damage, and ordering a legacy replacement can be costly and disrupt cleanroom operation. To avoid these problems, order replacements at the time you purchase the pass-through chamber; simply add “-RH” (for right-side hinge) or “-LH” (for left-side hinge) to the part number of the chamber.

Access Clearances 
Width = W (nominal) – 1.88”
Depth = D (nominal) – 0.12”
Height = H (nominal) – 1.25”
Wall Cut-Out = W (nominal) +2” x H (nominal) + 1.5”
Mounting Illustration with Door Swing Direction
Popular Accessories
For a full list of accessories, select a product then click Choose Accessories on that product page.
  • Passthrough Ventilation Exhaust Ducts

    Adding a duct flange to the top of the passthrough allows the chamber to be ventilated by a remote blower. The ULPA-filtered inlet, housed in a perforated stainless steel cage, provides the necessary make-up air without contaminating the chamber.
  • CleanTop™

    The CleanTop™ is designed for installations that require the chamber to be centered in the wall. The 30° sloping top on the cleanroom-side minimizes particle accumulation and accommodates laminar downward airflow.
  • Replacement Pass-Through Doors to Avoid Costly Down-Time

    Avoid costly disruptions and down time - keep a replacement door on hand! Doors attach in minutes and can prevent a costly shut-down if the original is damaged. To order, add "-LH" (left-side hinge) or "-RH" (right-side hinge) to the pass-through part number.
  • Grounding Terminals

    Grounding terminals are ideal for the most static-sensitive applications (must be ordered with chamber; cannot be retrofitted).
  • Mounting System for Tempered Glass Wall Panels

    This unique mounting system allows installation of pass-through chambers on Terra Universal's modular cleanrooms with tempered glass wall panels.
  • Support Brackets for Pass-Through Chambers

    Stainless steel support brackets are recommended for pass-throughs deeper than 24". Brackets fasten to the wall and the body of the chamber rests upon the horizontal bar; no fasteners are used on the pass-through itself.
  • Passthrough Chamber Door Stop

    This stainless steel door stop limits the arc of the pass-through door's swing to 90°, preventing damage to wall, door latch and other components. Door stops can be adjusted to allow other angles.

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.