Specialty Laboratory Hoods

26 products meet your criteria.

per page
  1. ValuLine™ Mobile Laminar Flow Cabinet with UPS Battery System
    Group of 2 products
    9715-PP-01
    From
    As low as $5,296
    Some ship in 10 - 15 days
    CE Mark LogoCE Mark LogoULus LogoULus LogoISO 6 IconISO 6 Icon
    2 Type1 Design2 Material2 Configuration1 Width1 Depth2 Height1 Shelves1 ISO Class

    • Available ISO Ratings: ISO 6, ISO 7, ISO 8
    • Mobile laminar flow cabinet provides a safe, economical, contamination-free way to transport materials
    • Cleanroom compliant storage cabinet provides ISO 5 Class 100 positive-pressure, particle-free environment
    • Handy and convenient Uninterruptible Power Supply (UPS) provides power when and where you need it
    • Battery system supplies approximately 1-2 hr runtime depending on FFU speed setting
    • FFU with EC motor offers high performance, low energy consumption, and low noise levels (40 dB)
    Type: HEPA-Filtered, ULPA-Filtered
    Design: Free Standing
    Material: Polypropylene, 304 Stainless Steel
    Configuration: HEPA-Filtered, ULPA-Filtered
    Width: 48"
    Depth: 24"
    Height: 80", 38"
    Shelves: 3 Shelves
    ISO Class: ISO 6
  2. UVP PCR Workstation by Analytik Jena
    Group of 4 products
    1016-PP-09
    From
    As low as $5,121
    Some ship in 10 - 16 days
    1 Voltage1 Model4 Filter Type1 Inside Width1 Inside Depth1 Inside Height

    • 254nm UV irradiation reduces surface and airborne decontamination
    • Easy-clean antimicrobial coating
    • Safety shut-off switch automatically turns the UV light off when door is opened
    • Makrolon® panels block all UV light below 400nm
    • Enclosures compatible with Cybio® Felix Automated Liquid Handling
    Voltage: 115 V
    Model: Polymerase Chain Reaction Hood
    Filter Type: HEPA, None, HEPA/UV Light, UV Light
    Inside Width: 31"
    Inside Depth: 21.5"
    Inside Height: 29"

    • Meets all requirements for USP 797 compliance
    • Unit Dimensions without Stand: 50”W X 27”D X 57 ½”H (1270 x 686 x 1460.5 mm) Unit Weight: 2700 lbs. (1225 kg)
    • Provides ISO Class 5/Class 100 HEPA filtered unidirectional (laminar) vertical airflow
    • Material: 100% Stainless Steel with pharmaceutical grade finish
    • Includes 37" tall all-welded stainless steel stand
  3. ISO 7 IconISO 7 IconStockedStocked

    • Available ISO Ratings: ISO 7, ISO 8
    • Enclosed work area improves ventilation performance
    • Stainless steel construction offers durability and easy-to-clean surfaces
    • Heavy-duty, stainless steel knobs control the LED lights and blower
    • Includes hinged access shield that increases air speed by restricting the air exhaust
    • Open-bottom design for versatility; work surface not included

    • UV opaque and resistant tempered safety glass sides and sash
    • Interlocked UV Protection Panel closes sash opening
    • Front-mounted 3-way light switch alternates between fluorescent, UV light, and off
    • 20° angled and hinged sash that pivots upward, locks to a loading height of 20”
    • Two utility ports with iris openings and plugs
  4. Bel-Art Clear View Fume Hoods
    Group of 2 products
    3308-PP-05
    From
    As low as $1,923
    Some ship in 15 - 25 days
    ISO 8 Icon
    ISO 8 Icon<br/>
    1 Voltage1 Type1 Frame Material2 Width1 Height1 Model2 Manufacturer SKU1 ISO Class

    • Available ISO Ratings: ISO 8
    Voltage: 12 V
    Type: Ducted
    Frame Material: Powder-Coated Steel
    Width: 24", 42"
    Height: 26"
    Model: ClearView
    Manufacturer SKU: 50020-1010, 50020-2010
    ISO Class: ISO 8
  5. ISO 7 IconISO 7 IconULus LogoULus LogoWhisperFlowWhisperFlowStockedStocked

    • Available ISO Ratings: ISO 7, ISO 8
  6. Custom and Walk-In Laboratory Fume Hoods by Genie (3646-11)
    Request Quote
    Usually ships in 18 - 22 days

  7. ISO 7 IconISO 7 IconStockedStocked

    • Available ISO Ratings: ISO 7, ISO 8
    • Includes hood, vapor-sealed fluorescent light, and two High 3000 RPM blower
    • High capacity blower maintains air speed 181 fpm of vertical working room
    • Features a quick-release filter housing
    • Operation Status Indicator flashes if fan is not operational
    • Not for use with flammable or explosive materials
  8. Universal Containment Hoods
    Group of 4 products
    1675-PP-07
    From
    As low as $4,668
    Some ship in 10 - 12 days
    ULus LogoULus LogoWhisperFlowWhisperFlowQuickBuildQuickBuildISO 6 IconISO 6 Icon
    1 Voltage4 Width1 Depth1 Height1 Sash Opening1 Hood Material1 Model1 ISO Class4 Inside Width1 Inside Depth1 Inside Height1 Side Panels

    • Available ISO Ratings: ISO 6, ISO 7, ISO 8
    • Frame Material: Polypropylene
    Voltage: 120 V
    Width: 48", 36", 72", 60"
    Depth: 30"
    Height: 42"
    Sash Opening: 15"
    Hood Material: 304 Stainless Steel Frame
    Model: Exhaust Fume
    ISO Class: ISO 6
    Inside Width: 46", 34", 70", 58"
    Inside Depth: 28"
    Inside Height: 28"
    Side Panels: Panels are not included (order separately)
  9. BioSafe® Universal Containment Hoods
    Group of 4 products
    1675-PP-14
    From
    As low as $4,509
    Some ship in 10 - 12 days
    ULus LogoULus LogoWhisperFlowWhisperFlowQuickBuildQuickBuildISO 5 IconISO 5 Icon
    1 Voltage4 Width1 Depth1 Height1 Sash Opening1 Hood Material1 Model1 ISO Class4 Inside Width1 Inside Depth1 Inside Height

    • Available ISO Ratings: ISO 5, ISO 6, ISO 7, ISO 8
    Voltage: 120 V
    Width: 36", 48", 72", 60"
    Depth: 30"
    Height: 42"
    Sash Opening: 15"
    Hood Material: 304 Stainless Steel Solid Wall
    Model: Exhaust Fume
    ISO Class: ISO 5
    Inside Width: 34", 46", 70", 58"
    Inside Depth: 28"
    Inside Height: 28"
  10. Stocked
    Dead-Air Hoods (No Air Circulation)
    Group of 3 products
    4950-PP-08
    From
    As low as $678
    Some ship in 1 - 3 days
    ISO 7 IconISO 7 IconStockedStocked
    3 Frame Material1 Width1 Height1 Sash Opening1 Model2 ISO Class3 Side Panels

    • Available ISO Ratings: ISO 7, ISO 8
    Frame Material: Clear Acrylic, Static-Dissipative PVC, Non-Dissipative PVC
    Width: 20"
    Height: 12"
    Sash Opening: 4"
    Model: Dead Air Mini-Hood
    ISO Class: ISO 8, ISO 7
    Side Panels: Clear Acrylic, Static-Dissipative PVC, Non-Dissipative PVC
Page 1 of 1

26 products meet your criteria.

per page

Features and Benefits

Critical Environment Solutions

Terra's mission is to help customers in highly regulated industries transform the world with critical environment solutions that improve health, safety, performance, and yields. These environments may comply with stringent UL, ISO, IEST, ASTM and OSHA standards and local requirements.

Dedication to Business Ethics

Terra is committed to conducting business according to the highest standard of professional ethics and conduct. To review Terra’s ethics code, please visit: https://www.terrauniversal.com/ethics-policy/

Top-Tier Clients

Terra’s key customers include some of the largest research labs, production facilities and universities in the world

Long-Standing Industry Expertise

For 45 years, Terra has served the life science, academic research, pharmaceutical, biotechnology, medical device, semiconductor and aerospace markets. We intimately understand the cGMP, GLP, ISO, ASTM , IEST and OSHA requirements.

Removable Rear Plenum for Exhaust or Recirculation

An optional adjustable rear plenum mounts on the back wall of a benchtop laminar flow hood to exhaust or recirculate air (flexible ducting not included). Rear exhaust helps minimize turbulence and optimize laminar airflow in the work area.

PCR Clean Workstations

Turnkey laminar-flow ISO 5 PCR Hoods are designed for cloning and amplifying RNA and DNA. They also include UV-C disinfection lamps and pipette shelves.

Polypropylene Laminar Flow Containment Hood

Provides a particle-free environment for work with sensitive materials

Specialty Laboratory Hoods

  • Labconco Protector ClassMate Labconco Protector ClassMate
  • Labconco Xpert Balance Enclosure – 8 ft Labconco Xpert Balance Enclosure – 8 ft
  • Labconco Xpert Balance Enclosure – 4 ft Labconco Xpert Balance Enclosure – 4 ft
  • Labconco Xpert Nano Ductless Exhaust Hood Labconco Xpert Nano Ductless Exhaust Hood
  • PCR Workstation PCR Workstation
  • Explosion-Proof WhisperFlow Hood Explosion-Proof WhisperFlow Hood
  • Terra Universal IQ-OQ Process
Technical Resources

Laminar Flow and Fume Hoods FAQs

Laboratory hoods serve a number of critical purposes in the lab environment.

Product protection from particulate contaminants in the lab environment, including microbes

Such hoods, often called laminar flow workstations or clean benches, use a flow of HEPA-filtered air to prevent influx of viable and non-viable particles into the enclosure and to sweep away any contaminants generated by the work process.

Protection of personnel and lab environment from substances generated inside the enclosure

For fume containment, laboratory fume hoods use a ducted ventilation system that maintains negative pressure. Where ducting is impractical, ductless hoods are also available for removal of non-hazardous contaminants (fumes or particles), using either HEPA or activated carbon filters.

Protection of product, operator and environment

Biological safety cabinets combine aspects of both hood types: a laminar flow of micro-filtered air and negative-pressure containment of bio-hazard fumes.

Laminar Flow Hoods

Laminar flow hoods (also called laminar flow clean benches) force air through a HEPA or ULPA filter to create a clean work area free of nearly all contaminating particulates, including bacteria, mold spores and many viruses. These hoods use a vertical or horizontal airflow design. Both provide excellent protection of products from particulates and cross-contamination, but do not protect the operator or environment.

So why choose one over the other? Vertical laminar flow hoods (VLF Hoods) require less floor space, but more overhead clearance. In addition, a sash at the front of the VLF hood provides a barrier between air exiting the hood and the operator’s face. VLF hoods create turbulent air flow when air strikes the work surface, requiring sterile work to be performed above the work surface.

HLF hoods minimize air turbulence (and particle backflow) on the work surface except where equipment disrupts the horizontal airflow. However, they direct the airflow directly at the operator’s face and require more depth to accommodate placement of the fan filter unit at the rear of the hood.

Read more about the differences between horizontal and vertical laminar flow hoods

Fume Exhaust Hoods

Laboratory fume hoods draw air from the environment through the opening of the hood, allowing environmental contaminants into the work area. Thus, lab fume hoods do not offer a sterile environment or product protection. Instead, chemical fume hoods are designed to protect the operator from dangerous or irritating fumes and powders generated from work performed inside the hood.

In ducted fume hoods and canopy fume hoods, air passes out of the hood through a duct leading to an in-house ventilation system that contains and/or neutralizes hazardous materials.

In ductless fume hoods, fans draw exhaust air through a series of filters that remove irritating substances before release back into the room. Since these filters are not 100% efficient in removing all substances, ductless fume hoods are not advised in the presence of biohazards; however, they provide a convenient, cost-effective solution for operations involving irritating but non-hazardous fumes in facilities where an in-house HVAC system cannot be accessed.

Biosafety Cabinets

Biological Safety cabinets combine design aspects of both laminar flow and fume hoods. Filtered air is directed downward onto the work surface and then travels into a plenum through openings on the front and sides of the hood. Depending on the classification of the biosafety hood, some percentage of air is recirculated through a HEPA filter while the rest is directed out of the hood through an exhaust system. Thus, biosafety cabinets offer operator, environmental and product protection.

These laboratory safety cabinets (sometimes called IV hoods or compounding hoods) are ideal when preparing sterile medications such as chemotherapeutic agents that may pose a risk to the operator.

BSCs, BSLs, and ISO Classes

When it comes to working with hazardous or potentially infectious material, protecting personnel must be the primary concern. However, offering personnel protection does not have to come at the cost of risking product integrity. Class II BSCs provide protection to both personnel and product simultaneously. They maintain an ISO class 5 clean work area for product manipulation, while ensuring that exhaust air is filtered and ducted out of the environment. Thus, a class II BSC is the ideal solution when working with moderately hazardous material and both personnel and product safety are required.

Read more about these lab hoods here regarding their biological safety rating

3 Item(s)




Can't find what you're looking for?
Tell us what you need and we'll build it!



SUBMIT A QUICKQUOTE REQUEST


Need Help?

(714) 578-6100

EMAIL CHAT

Mon - Fri, 5:30am - 5:30pm PST