39728
Cleanroom; Powder Containment, Powder-Coated HR Steel
Product Details
  • Available ISO Ratings: ISO 5, ISO 6, ISO 7, ISO 8
  • Dimensions: Ceiling clearance is 7' ( 2134 mm) from filter face to floor (8'3" ( 2515 mm,) overall, including filter/fan units)
  • Material: Double-wall, powder-coated hot rolled steel smooth-surface construction is easy to wipe down, resists a wide range of solvents, germicides and other chemicals
  • Includes powder-coated steel ceiling grid (FFU and light supports) that forms 2" x 4" (51 mm x 102 mm) bays for filter/fans, lights or blank panels (order ceiling modules separately)
  • System includes a BioSafe all-steel room manufactured to the floor plan you specify, including ceiling grid.
  • Order desired quantity of CleanZone Recirculation System P/N 6600-84 separately.  Unless otherwise specified, standard installation is center of wall opposite entrance.
  • Four-foot opening on the shorter wall accommodates one of Terra's standard door options-- order parting cleanroom vinyl strip shields or swing doors separately
  • Control Panel provides on/off switches for FFUs, lights and other system options, and includes Status Indicators (order separately)
  • The ideal enclosure for purity testing, weighing, and packaging pharmaceutical powders
  • Recirculating, HEPA-filtered air flow protects from room contaminants while containing and collecting Dimensions: Ceiling clearance is 7' ( 2134 mm) from filter face to floor (8'3" ( 2515 mm,) overall, including filter/fan units)
  • Rear-mounted air vents draw air away from work area
  • This system is designed to ventilate environmental nuisances away from the operator; it is not intended to provide personnel or environmental protection against biohazardous substances.  For biohazards, select a Biological Safety Cabinet or similarly certified equipment.
  • Ceiling filter/fan unit operates at industry-best low noise and vibration level, provides an average air flow velocity of 90 feet per minute (0.5 m/s)
  • Options ordered separately: MAGNEHELIC(R)  gauge, self-balancing bars, power outlets and work benches
  • Terra assumes no responsibility for meeting local building regulations, including fire and seismic codes.  Check your local planning department to see what regulations apply to your installation.

Frame Material: Powder-Coated Steel

Overall Dimensions: Custom

Panel Material: Powder-Coated Steel

Unit of Measure: EA

Marks & Listings: UL, ULC

Electrical Specifications: None

Package Type: Skid

Manuals & Resources
Blog Post
Cleanroom FAQs blog post
Answers to both basic cleanroom questions as well as specific inquiries about Terra-made rooms. Useful insight for people with a new cleanroom, or thinking about ordering one.
Buy Accessories
  1. WhisperFlow Fan/Filter Units feature internal baffling and anodized aluminum diffuser panels provide quiet, uniform air fow  |  6601-24-H displayed
    $1,264
    Increase Down Increase Up
  2. Room-Side Replaceable (RSR) WhisperFlow Fan/Filter Units allow filter replacement from inside of the cleanroom  |  6601-24A-UR displayed
    $1,400
    Increase Down Increase Up
  3. 2'W x 4'D LED panel mounted in Terra Universal Cleanroom  |  3800-41 displayed
    $437
    Increase Down Increase Up
  4. Double stacked cleanroom LED strip lights installed to the ceiling of a cleanroom  |  3800-40A displayed
    Request Quote
    Increase Down Increase Up
  5. 2' x 4' Cleanroom LED Panel Light with emergency backup battery and battery test switch  |  3800-47 displayed
    $1,181
    Increase Down Increase Up
  6. Simplifies the connections of fan filter modules and ceiling lights  |  6600-29B-P displayed
    $2,354
    Increase Down Increase Up
  7. Dramatically simplify connection of fan/filter modules and ceiling lights  |  6600-29B-S displayed
    $2,354
    Increase Down Increase Up
  8. Cleanroom control panel provides centralized control and monitoring of cleanroom functions; status indicator LED blinks when FFU filters need replacement  |  6600-23A-NS displayed
    $4,326
    Increase Down Increase Up
  9. Curtain panels mounted in a ValuLine Softwall Cleanroom.  |  1320-34 displayed
    $223
    Increase Down Increase Up
  10. Curtain panels mounted in a ValuLine Softwall Cleanroom.  |  1320-34 displayed
    Request Quote
    Increase Down Increase Up
  11. Suitable for all classes of cleanrooms and all levels of process isolation  |  1320C-08 displayed
    $48
    Increase Down Increase Up
  12. Suitable for all classes of cleanrooms and all levels of process isolation  |  1320C-08 displayed
    $57
    Increase Down Increase Up
  13. Flexible strip shields and panels in several cleanroom-compatible materials create an economical softwall enclosure  |  6704-07 displayed
    $310
    Increase Down Increase Up
  14. Flexible strip shields and panels in several cleanroom-compatible materials create an economical softwall enclosure  |  6704-07 displayed
    $376
    Increase Down Increase Up
  15. Suitable for all classes of cleanrooms and all levels of process isolation  |  1320S-08 displayed
    $48
    Increase Down Increase Up
  16. Suitable for all classes of cleanrooms and all levels of process isolation  |  1320S-08 displayed
    $57
    Increase Down Increase Up
  17. Provides a stream of static-neutralizing ions to protect ESD-sensitive components.
    $997
    Increase Down Increase Up
  18. Specify sprinkler location in accordance with local fire code  |  6600-90 displayed
    $13
    Increase Down Increase Up
  19. Close-up of roof truss (cyan) installed to 12’H hardwall cleanroom frame; connector (pink) anchors cleanroom ceiling to overhead beam to reduce weight load  |  6609-01 displayed
    Request Quote
    Increase Down Increase Up
  20. 304 Stainless steel BioSafe® crash rail features continuous-seam welds to meet strict cleanliness protocols  |  6600-88 displayed
    Request Quote
    Increase Down Increase Up
  21. Stainless steel T-bar mount fastens softwall curtain GripTrack to the ceiling grid  |  6704-09A displayed
    $3
    Increase Down Increase Up
  22. Suitable for all classes of cleanrooms and all levels of process isolation  |  1320S-08 displayed
    $48
    Increase Down Increase Up
  23. Two retaining arms hold panels on both sides of ceiling joist  |  6705-95 displayed
    $91
    Increase Down Increase Up
  24. Designed to ventilate environmental nuisances away from the operator  |  6600-84 displayed
    $2,663
    Increase Down Increase Up
  25. Designed to ventilate environmental nuisances away from the operator  |  6600-85 displayed
    $2,663
    Increase Down Increase Up
  26.  |  6703-81 displayed
    $119
    Increase Down Increase Up
  27. Won't shed particles or outgas, making them ideal for all cleanliness classifications.
    $38
    Increase Down Increase Up
  28. Duplex power outlet: 120VAC shown.  |  6704-34 displayed
    $443
    Increase Down Increase Up
  29. Includes plumbing of vacuum line and installation of quick connection fitting  |  6705-07 displayed
    $455
    Increase Down Increase Up
  30. Includes plumbing of vacuum line and installation of quick connection fitting  |  6705-07 displayed
    $455
    Increase Down Increase Up
  31. HVAC units ensure comfort and productivity of garbed cleanroom personnel.  |  6704-31 displayed
    $6,182
    Increase Down Increase Up
  32. Measure and control both positive and negative low air or gas pressures  |  2625-08 displayed
    $170
    Increase Down Increase Up
  33. Measure and control both positive and negative low air or gas pressures  |  2625-09 displayed
    $148
    Increase Down Increase Up
  34. Magnehelic differential pressure gauge, 0" - 2" WC  |  2625-10 displayed
    $154
    Increase Down Increase Up
  35. Measure and control both positive and negative low air or gas pressures  |  6600-86 displayed
    $560
    Increase Down Increase Up
  36. Differential Pressure Gauge; 0-4.0" WC, Magnehelic®, Installed
    $428
    Increase Down Increase Up
  37. Differential Pressure Gauge; 0-3.0" WC, Magnehelic®, Installed
    $416
    Increase Down Increase Up
  38. Differential Pressure Gauge; 0-2.0" WC, Magnehelic®, Installed
    $416
    Increase Down Increase Up
  39. Differential Pressure Gauge; 0-1.0" WC, Magnehelic®, Installed
    $416
    Increase Down Increase Up
  40. Measure and control both positive and negative low air or gas pressures  |  2625-08 displayed
    $429
    Increase Down Increase Up
  41. Measure and control both positive and negative low air or gas pressures  |  2625-12 displayed
    $200
    Increase Down Increase Up
  42. Measure and control both positive and negative low air or gas pressures  |  2625-11 displayed
    $147
    Increase Down Increase Up
  43. Differential Pressure Gauge; -0.25-0-0.25" WC, Photohelic®, Uninstalled
    $813
    Increase Down Increase Up
  44. Silicone sealant is RTV food grade  |  3052-30 displayed
    $11
    Increase Down Increase Up
  45. Service, ISO 5 Rating Declaration
    Request Quote
    Increase Down Increase Up
  46. Warranty; 2 Year, Terra-Manufactured Product, Parts
    Request Quote
    Increase Down Increase Up
  47. Warranty; 3 Year, Terra-Manufactured Product, Parts
    Request Quote
    Increase Down Increase Up
  48. FasTrak 24-7 Expediting Service
    Request Quote
    Increase Down Increase Up
  49. White Glove Freight Service
    Request Quote
    Increase Down Increase Up
  50. Qualification Documentation (IQ/OQ) for Terra Universal System
    Request Quote
    Increase Down Increase Up
  51. Cleanroom Installation Information
    Request Quote
    Increase Down Increase Up
  52. Cleanroom Cleaning Service
    Request Quote
    Increase Down Increase Up
  53.  |  6600-98 displayed
    Request Quote
    Increase Down Increase Up
  54. Equipment Testing
    Request Quote
    Increase Down Increase Up
  55. Floor Survey Service
    Request Quote
    Increase Down Increase Up

Hardwall Cleanrooms

  • Class 100,000 Hardwall Clean Room Equipment Enclosure for Conveyor Line
  • Explosion-Proof Softwall Modular Cleanroom Explosion-Proof Softwall Modular Cleanroom
  • Insulated Hardwall Modular Cleanroom Insulated ISO-Rated Hardwall Modular Cleanroom
  • Explosion-Proof Softwall Cleanroom Explosion-Proof Softwall Cleanroom
  • Portable HEPA Filtration System Watch Terra's Portable HEPA Filtration System Video
  • Modular Office Production Control Room Modular Production Control Room
  • Modular Office Warehouse Operations Modular Warehouse Office
  • Insulated Hardwall Cleanroom Insulated Hardwall Cleanroom
  • Mezzanine Cleanroom Mezzanine Cleanroom
Portable HEPA Filtration System

Features and Benefits

Learn More: BioSafe Features

More Information

All-Steel BioSafe Panels

Engineered for ease of installation and cleaning, BioSafe Cleanroom wall panels come in standard 4-foot widths and heights ranging from 7 to 12 feet. Their modular design lets you configure a custom cleanroom using pre-engineered components, many of which are inventoried at Terra’s Fullerton, California manufacturing facility.

Terra technicians assemble and test each BioSafe Cleanroom to ensure it meets performance requirements prior to packaging. Panels and other components are labeled before crating to simplify installation, which typically requires no special contracting or permitting (on-site installation and testing services are available). Whether your requirements call for a single room or a multi-suite facility, your BioSafe Cleanroom is operational in a fraction of the time and at a fraction of the cost associated with conventional cleanrooms.

Each wall section is composed of two panels that snap together, with space in between for insulation or utilities, similar to a conventional wall. Wall sections are bolted end-to-end to form a continuous interior wall surface with very fine seams that can be caulked if necessary. Wall panels can be fitted with flush-mounted BioSafe windows or any of Terra’s cleanroom door designs. Certain panels will include the required exhaust vents; customers can specify the addition of an exterior exhaust plenum that covers these vents and directs exhaust airflow to an external air handling system. Air return plenums may also be used to recirculate conditioned air to maintain suitable working temperatures and save energy.

Multi-Room Configurations

BioSafe wall panels function equally well as exterior and interior cleanroom walls, which simplifies engineering of multi-room facilities. Corridors and anterooms can be added where necessary by regulation or to provide additional barriers against cross-contamination. These intermediate spaces help to maintain proper air pressure by providing neutral buffer spaces. They also may serve as convenient staging areas for supplies and other materials. Pass-through chambers can also be used for more staging and transfer, as well as simply limiting the number of personnel in a critical area.

The modular ceiling grid can be configured for different ISO-classifications through appropriate placement of fan/filter units. FFUs can be positioned (and repositioned) in the ceiling grid to concentrate clean air in the most critical processing areas. Rooms with less critical cleanliness requirements may operate with fewer FFUs, reducing energy and maintenance expenses. For example, a gowning room may only need one FFU to ensure a slight overpressure that limits leakage.

As FFU configurations become more complex, Terra can provide more advanced control systems, from PLC touchscreen controllers to fully automated air balancing systems. In addition, security measures can be integrated into the various access points of the cleanroom, including biometric scanning equipment and access logs.

Accredited Technical Cleanroom Expertise

We are committed to provide our clients with a full service solution, from project planning through engineering, product design, manufacturing, procurement, shipping, installation, validation, commissioning, and preventative maintenance. Our team of qualified professionals collaborates with all stakeholders to deliver innovative solutions at every stage of the project.

Cleanroom LED Light Panel with Emergency Power Supply, 2' x 2'

Cleanroom LED lights are equipped with emergency back-up batteries to ensure continued operation in the event of a power failure.

Long Running FFU Motors

Terra’s filter fan unit motors are rated for 5 years of continuous, 24/7 operation, if the HEPA filters are consistently replaced. To accurately monitor your HEPA filter’s saturation levels, purchase Terra’s audible and visual filter replacement alarm system.

Complete Order Transparency

Using Terra’s OnTrak system, our customers can view real-time production updates, receive shipment notifications and track their orders until they arrive at their facility

4,000 Worldwide Cleanrooms

Since 1976, Terra has designed and manufactured over 4,000 cleanrooms for companies at the leading edge of high technology

Manufacturer, Distributor and Service Provider

Terra is not just a product manufacturer, we provide a suite of services to help our customers navigate the complex process of ensuring their equipment is operational

Products Compliant With Your ISO Rating

Provide Terra with your desired ISO rating. We will tailor the product to meet your rating and supply a certificate of compliance appended to your invoice, to be included in your compliance package. All certificates are archived in Terra's system for quick retrieval.
Popular Accessories
For a full list of accessories, select a product then click Choose Accessories on that product page.
  • BioSafe® Hygienic Crash Rails

    BioSafe® stainless steel crash rails feature continuous-seam welds for a smooth finish that is easy to clean. Eliminates hard-to-clean cracks and crevices where particles and germs can accumulate.
  • Lighthouse Handheld Airborne Particle Counters

    Lightouse portfolio of handheld airborne particle counters ensure accurate readings of cleanrooms and critical environments
  • Germicidal UV Lamp Sanitizes Labs, Cleanrooms

    UV-C Germicidal Lamp installs on a cleanroom ceiling grid for line-of-sight room disinfection; safety occupancy sensor prevents personnel exposure.
  • CleanZone Recirculation System Stacked Filters

    CleanZone Filtration System, shown with stacked exit filters, recirculates air though a ceiling HEPA filters
  • CleanZone Recirculation System Side-by-Side Filters

    CleanZone Filtration System, shown with side-by-side exist filters, recirculates air though a ceiling HEPA filters
  • WhisperFlow® Cleanroom Fan Filter Units

    Design features internal baffling and an aluminum diffuser to provide quiet operation along with uniform air speed for ISO-compliant laminar flow.
  • Ionizing Bar

    For use on 24" x 48" ( 610 x 1219 mm) filter/fan units only (Order FFUs separately).
  • Light Panel, LED; 2 x 4, 4500 Lumens, 120-277V, 50/60 Hz, Installed

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.