  • Available ISO Ratings: ISO 5, ISO 6, ISO 7, ISO 8
  • Fire-rated windows protect personnel, equipment, and facility by maintaining the integrity of the fire-rated wall
  • Tested and Certified to ANSI/UL 9 (positive pressure) for 45-minute fire exposure
  • Easy-mount frame is seamless on flush side without crevices where particles and contaminants can accumulate
  • Medical-grade, USP-compliant 316L stainless steel, compatible with all areas of hospitals and aseptic environments
  • •  Max Frame Size: 75-3/4"W x 51-7/8"H x 2"Thick
  • Flush-mount fire-rated window and frame assembly, intended for 45 min. rating, tested in accordance with UL 9 Fire Tests, UL File GVTV.R39784.
  • Designed for quick, easy installation in a variety of wall materials and thicknesses.
  • Clean and Durable 316L Stainless Steel Frame:
  • Meets ISO 5 classification on the flush-mount side and ISO 6 classification on the back side.
  • Easy-to-sterilize 316L stainless steel window frame with continuous seam welds for sterile bio-pharma applications
  • All-316L stainless steel surfaces with enhanced corrosion resistance stand up to harsher cleaning agents and withstand degradation from bleach-based disinfectants.
  • Frame size:
  • Max. Overall Dimensions: 75-3/4 in. x 51-7/8 in.
  • Max. Area: 3,929 sq.in.
  • Max. Wall Cut-Out: 76-3/4 in. x 52-7/8 in.
  • Glass Size:
  • Max. Exposed Area: 3,302 sq.in.
  • Max. Exposed Width: 70-5/8”
  • Max. Exposed Height: 46-3/4”
  • Fire-Rated Glazing: Pilkington PyroStop 60-101, single glazing (multi-laminate), nominal 7/8” thick, 10.86 lb/ft2
  • NOTE:
  • Glass glazing ships separately and must be installed into frame by customer.
  • Due to widely varying building codes, it is the responsibility of the architect/owner and installer to ensure the window assembly, glazing material, and other hardware complies with all applicable local building codes and laws.
  • Window assembly may be installed in steel stud/gypsum board, masonry or concrete assemblies having a minimum of 1 hr fire rating. The 1 hr fire rated steel stud/gypsum board wall assembly is to be constructed in accordance with UL Wall Design No. U419 as described in UL’s ProductiQ.  The wall assembly should be minimum No. 20 steel studs (structural steel), minimum 3-5/8 in. wide, spaced maximum 16 in. OC and faced with a single layer of nominal 5/8 in. thick Type X (Classified for Fire Resistance) gypsum board.
  • UL burn test video

Fire-Rating: 45 Min.

Frame Material: 316L Stainless Steel

Pane Thickness: 0.875"

Window Type: Single Pane

Available ISO Ratings: ISO 5, ISO 6, ISO 7, ISO 8

ISO Class: ISO 5

Unit of Measure: EA

Marks & Listings: UL

Buy Accessories
  1. FasTrak 24-7 Expediting Service
    Request Quote
    Increase Down Increase Up
  2. White Glove Freight Service
    Request Quote
    Increase Down Increase Up
  3. Service, ISO 5 Rating Declaration
    Request Quote
    Increase Down Increase Up

Fire-Rated Cleanroom Windows

  • Fire-rated cleanroom window burn test Watch Terra's Video of a Fire-Rated Cleanroom Window Burn Test
  • BioSafe cleanroom window Terra Universal's Biosafe® Windows
  • Easy installation of framed window Framed Single Windows
  • BioSafe flush-mount frameless double window installed in laboratory BioSafe Flush-Mount Frameless Double Window
  • Double-Sided Flush-Mount Frameless Window Double-Sided Flush-Mount Frameless Window
  • BioSafe Double-Sided Stainless Steel Framed Window Tempered Glass BioSafe Double-Sided Stainless Steel Framed Window Tempered Glass
  • Cleanroom Barrier Wall with Tempered Glass Windows
  • Tempered Glass Window For Clean Room Double-Sided Tempered Glass Windows for BioSafe Steel Cleanroom
Fire-rated cleanroom window burn test
BioSafe cleanroom window
Easy installation of framed window

Features and Benefits

Products Compliant With Your ISO Rating

Provide Terra with your desired ISO rating. We will tailor the product to meet your rating and supply a certificate of compliance appended to your invoice, to be included in your compliance package. All certificates are archived in Terra's system for quick retrieval.

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.