FREE CONSULTATION714-578-6100
  1. Home
  2. Pumps & Compressors
  3. Vacuum & Pressure Pumps
  4. Dry Roughing Pumps

Dry Roughing Pumps

Adixen Dry Roughing Pump ACP 15 Series
Dry Roughing Pumps
Alcatel Part # Cat. # Price
V5SATSMFAF 7901-33 Price
  • Reliable, clean, high-performing laboratory and cleanroom dry pumps for inert gas pumping
  • Oil-free operation with universal single-phase power
  • With a frictionless design and no wearing parts, no particulate contamination can result
  • No hydrocarbon backstreaming due to lubricant-free pumping module
  • Constant pumping speed and ultimate pressure due to constant internal clearances
  • With complete overhauls due only every 20,000 hours, maintenance costs are low

These Dry Roughing Pumps are extensively field proven and provide clean, low-maintenance, reliable operation in laboratories and cleanrooms. Their compact design allows for easy integration into all applications.

Outstanding Features
The single-phase frequency converter allows these pumps to be powered in the range of 100 V to 230 V 50/60 Hz through a standard IEC connection with automatic voltage range selection. Rotational speed and pumping speed remain constant regardless of voltage and frequency.

A digital timer gives information about accumulated operational hours for maintenance purposes.

Remote control is facilitated through the Sub-D Connector located at the rear side.

Units are air cooled, so no water supply is required.


Performance Curves

Adixen Pumping Speed ACP 15 Series
Adixen Pressure Drop ACP 15 Series

 
Specifications
Description Cat. # 7901-33
Peak pumping speed 232.4 L/min
8.2 CFM
Ultimate pressure  
- Closed gas ballast
- Open gas ballast*
5.10² mbar
3.10¹ mbar
Maximum continuous inlet pressure 1013 mbar
Input voltage 90 V to 254 V
50/60 Hz
Power consumption
- at ultimate pressure
- atmosphere
520 W
600 W
Ambient temperature 12 to 40 ºC
Inlet port DN25 ISO-KF
Exhaust port DN16 ISO-KF
Tightness 5.10-7 mbar.l/s
Weight 23 kg
Overall dimensions: L x W x H 504 mm x 202 mm x 276 mm
For condensable vapors pumping capacity, please contact us.

The single-phase frequency converter allows these pumps to be powered in the range of 100 V to 230 V 50/60 Hz through a standard IEC connection with automatic voltage range selection. Rotational speed and pumping speed remain constant regardless of voltage and frequency.

Click to leave a message. 24-hour sales and tech phone support, M - F