Vertical flow of recirculating ULPA-filtered air from the ceiling protects materials during transfer and stops particles from landing on sensitive parts | 6705-72 displayed
LTL freight shipment. Dock or liftgate may be required.
Available Certified ISO Grade Designs: ISO 5, ISO 6, ISO 7, ISO 8
Vertical laminar flow of HEPA-filtered air removes airborne particles from the chamber
Vents along the bottom of the chamber recirculate air back to the filtration module
Electronic interlock with visual and audible door status alerts
CleanMount design allows for installation without drilling and prevents cleanroom shutdown for rapid servicing or replacement
Unit includes double-wall construction, which triples product lifespan and totally eliminates cleaning of accessories
• Special Door Configuration: Leak-Rated
• Material: 304 or 316L SS
• Mounting Position: Flush Wall
• Inside Width: 18"
• Inside Depth: 18"
• Inside Height: 18"
• Expand System Capabilities: 90° Corner Placement, Access Control System, Access Panel, Air Speed Sensor, Electronic Pass-Through Upgrade, HEPA-Filtration, Intercom, LED Lighting, Message Panel, Load Presence Sensor, Power Outlet, UV Sanitizer, Slide-Up Doors, Video Recording
• Wall Cutout: 28" W x 40" H
• HEPA/ULPA Filtration: Yes
• ISO Rated Air Cleanliness: ISO 5
• Unit of Measure: EA
Read more
Terra Part #: 6705-79-316
Manufactured By: Terra Universal
Warranty: 1 year parts, 90 days labor
LTL freight shipment. Dock or liftgate may be required.
PASSWORD REQUIRED
for
Summary
Available Certified ISO Grade Designs: ISO 5, ISO 6, ISO 7, ISO 8
Vertical laminar flow of HEPA-filtered air removes airborne particles from the chamber
Vents along the bottom of the chamber recirculate air back to the filtration module
Electronic interlock with visual and audible door status alerts
CleanMount design allows for installation without drilling and prevents cleanroom shutdown for rapid servicing or replacement
Unit includes double-wall construction, which triples product lifespan and totally eliminates cleaning of accessories
Blower controls include an on/off switch and infinitely variable speed control
Includes Minihelic pressure gauge for monitoring backpressure at the HEPA filter
Lift-off doors can be removed for thorough cleaning and sterilization
Doors are leak-rated by UL for tight seal to maintain cleanroom pressure gradients
WhisperFlow FFU built with quiet, low vibration design: less than 50 dBA, measured 30" from filter face at 90 FPM
Smooth interior surfaces, with seamless radius corners and lipless access, simplify cleaning and sterilization for critical bio/pharmaceutical use
Customer must determine if filter system leakage testing is required for their application. If a filter leak test is required, full-seam welded filter housing is optionally available, tested to meet ISO 14644-3
Integral clean-side bracket hugs cleanroom wall without fasteners or caulking to eliminate gaps that collect germs, other contaminants
Opposing "dirty-side" bracket snaps in place and features smooth, easy-clean surface with no visible fasteners
Door status alerts prevent door damage that results when users exert excess force on an engaged interlock
Smart® control system allows add-on capabilities: recessed LED or UV disinfection lamps, intercom, load presence sensors and camera, hands-free automatic door, access security system and more (order separately)
Stainless steel-reinforced, removable doors with PVC viewing windows
Stainless steel latches and hinges eliminate corrosion and contamination common with plated hardware
Power cord included and should be hardwired to power supply onsite per local code by a licensed electrician
Specifications
• Special Door Configuration: Leak-Rated
• Material: 304 or 316L SS
• Mounting Position: Flush Wall
• Inside Width: 18"
• Inside Depth: 18"
• Inside Height: 18"
• Expand System Capabilities: 90° Corner Placement, Access Control System, Access Panel, Air Speed Sensor, Electronic Pass-Through Upgrade, HEPA-Filtration, Intercom, LED Lighting, Message Panel, Load Presence Sensor, Power Outlet, UV Sanitizer, Slide-Up Doors, Video Recording
• Dimensions, Shipping: 33.25" W x 37.5" D x 49" H
• Package Type: Palletized
Features and Benefits
Durable Double Wall Construction
BioSafe double-wall construction triples unit lifespan and totally eliminates cleaning of accessories
Lift-Off, Non-Shedding Door Hinges
Non-shedding, barrel-type door hinges allow the doors to lift off for thorough cleaning and decontamination (no tools required). Unlike industry standard continuous designs, these hinges comply with strict ISO levels.
All Stainless Steel FFU with Removable Filter Replacement Screen
The pass through includes an all-stainless steel filter fan unit with a screen for easy HEPA filter replacement. The screen is held in place by double roller catches, which allow the screen to be easily popped out of the ceiling to access the HEPA filter.
Recirculating HEPA Filtration Diagram
By recirculating the interior air, airborne particles are rapidly removed by successive passes through the HEPA filter. Recirculation also minimizes pressure buildup that can cause leakage into an adjacent positive-pressure cleanroom.
Smart® Cleanroom Pass-Through with Full-Glass Doors
Hygienic and damage resistant full tempered glass doors are specifically designed for healthcare, pharmaceutical, and GMP manufacturing applications to help achieve FDA compliance. The outside surface of the tempered glass door is frameless to minimize cracks and crevices where particulates or microbes can colonize.
Air Return Slots for Recirculating HEPA Filtration
Air return slots along bottom interior of the cleanroom passthrough cabinet circulate air back through the built-in fan and HEPA filter to remove airborne particles inside the chamber.
Popular Accessories
For a full list of accessories, select a product then click Choose Accessories on that product page.
Designed to be installed into any pass through. Install these racks within minutes with no special tools. Simply tighten a compression screw. Forgot to order racks before? No problem!
Infrared beams detect objects placed inside the transfer chamber and connect to a remote alarm located up to 200 feet away from the pass through chamber. The crossed red lines depict the non-visible trigger lines between the IR transmitters and receivers.
Stainless steel support brackets are recommended for pass-throughs deeper than 24". Brackets fasten to the wall and the body of the chamber rests upon the horizontal bar; no fasteners are used on the pass-through itself.