CleanMount® Smart pass-through chamber with electronic interlock and door status alerts | 2635-10B-2-316 displayed
Smart® CleanMount® Pass-Through Chambers
Pass-Through; Smart®, CleanMount CleanSeam, 24" W x 24" D x 24" H ID, Flush Wall Mount, 304 or 316 Stainless Steel
Available ISO Ratings: ISO 5, ISO 6, ISO 7, ISO 8
Electronic cleanroom passthrough with Smart® Control System provides advanced control and monitoring
Unit includes double-wall construction, which triples product lifespan and totally eliminates cleaning of accessories
CleanMount design allows for installation without drilling and prevents cleanroom shutdown for rapid servicing or replacement
Hidden electronic interlock allows only one door to open at a time to prevent cross-contamination
Countless add-on capabilities: automatic doors, access security systems, UV disinfection, and more
• Special Door Configuration: Leak-Rated
• Material: 304 or 316 Stainless Steel
• Mounting Position: Flush Wall
• Inside Width: 24"
• Inside Depth: 24"
• Inside Height: 24"
• Expand System Capabilities: UV Sanitizer, Electronic Pass-Through Upgrade, 90° Door Placement, LED Lighting, Automatic Door, ULPA Air Shower, Intercom, Iris Scanner, Fingerprint Scanner, Video Recording, Power Outlet
Electronic cleanroom passthrough with Smart® Control System provides advanced control and monitoring
Unit includes double-wall construction, which triples product lifespan and totally eliminates cleaning of accessories
CleanMount design allows for installation without drilling and prevents cleanroom shutdown for rapid servicing or replacement
Hidden electronic interlock allows only one door to open at a time to prevent cross-contamination
Countless add-on capabilities: automatic doors, access security systems, UV disinfection, and more
Cleanroom pass throughs reduce foot traffic, improve cleanliness, safety, productivity, and much more.
Chamber Design:
Designed for sterile, regulated bio-pharmaceutical applications.
Electronic door interlock allows for unique, custom door swing configurations such as 90 degree corners (L-shape chambers), 3-door designs (T-shape chambers), 4-door designs (X-shape chambers), and more.
All 304-grade or 316-grade stainless steel with enhanced corrosion resistance stand up to harsher cleaning agents and withstand degradation from bleach-based disinfectants.
Continuous welds with coved radius corners and lip-less edges eliminate hard-to-clean cracks and crevices where contaminants can collect.
Double-wall construction greatly increases rigidity and durability of the pass through chamber to facilitate installation and prevent warping on larger chambers.
Flush-mount design removes dust accumulating surfaces inside the cleanroom.
Optional dual BioSafe® stainless steel racks easily remove for cleaning or sterilizing and are reversible to allow slide-out motion in either direction.
Quick and Clean Installation:
Innovative fastening system clamps to a variety of wall thicknesses without penetrating or damaging the finished surrounding wall.
The mounting frame is covered on both sides for an easy-to-clean finish with no visible fasteners or screws.
Easy-to-install mounting system also allows the entire passthrough chamber to be seamlessly removed and reinstalled within minutes, without damaging the surrounding wall.
Electronic Automatic Door Interlock:
Hidden Smart® control panel is mounted outside the transfer chamber (between double-wall) for easy-to-clean obstruction-free chamber interior.
Electronic interlock with Smart® Control System provides visual and audible door status alerts to prevent door damage that results when users exert excess force on an engaged interlock:
Green light indicates both doors available for use.
Red light and dual-side remote chimes indicate a door is open and interlock engaged.
Door Design:
Access doors with 304-grade or 316-grade stainless steel reinforced frames extend passthrough chamber's service life and provide a tight seal.
Santoprene® "e"-shape non-outgassing rubber gasket firmly compresses to eliminate leaks. The one-piece resilient rubber gasket maintains its shape after compression and won't flatten, warp, crack, or degrade like ordinary foam gasket. Gasket is also mechanically attached to the door frame to avoid adhesive failure common with gasket tapes.
Doors are leak-rated by UL for tight seal to maintain cleanroom pressure gradients.
Heavy-duty stainless steel lift latches included to minimize scratching, corrosion and contamination resulting over time that can occur with chrome-plated latches.
Sturdy "lift-off" stainless steel hinges are welded to the door frame and chamber. They are detachable to allow doors to easily lift off for trouble-free replacement or more thorough cleaning/decontamination.
Order replacement door(s) to avoid critical operation delays should a door be damaged and require immediate replacement.
Includes:
(1) Main power cord, to be hardwired to power supply onsite per local code by a licensed electrician.
(1) Automatic electronic interlock.
(2) Plug-in chimes (one for each side of the passthrough).
Mounting bracket system with cover plates. Standard mounting system accommodates 4"-6" wall thickness. Specify wall thickness at time of order.
Standard sized sloping top included for optional use on dirty side of pass-through. Accommodates wall thickness up to 5-1/2". If slope top is required for greater wall thickness, custom slope top to be ordered separately. Can be installed onto existing pass-through units.
Specifications
• Special Door Configuration: Leak-Rated
• Material: 304 or 316 Stainless Steel
• Mounting Position: Flush Wall
• Inside Width: 24"
• Inside Depth: 24"
• Inside Height: 24"
• Expand System Capabilities: UV Sanitizer, Electronic Pass-Through Upgrade, 90° Door Placement, LED Lighting, Automatic Door, ULPA Air Shower, Intercom, Iris Scanner, Fingerprint Scanner, Video Recording, Power Outlet
• Window Material: PVC
• Electropolished: Optional
• Storage Racks: Optional
• HEPA/ULPA Filtration: No
• Unit of Measure: EA
Helena
• Marks & Listings: UL, ULC
• Electrical Specifications: 120 V, 50/60 Hz
• Weight, Product: 237 lb
• Dimensions, Product: 34.5" W x 25" D x 36.06" H
• Weight, Shipping: 555.5 lb
• Dimensions, Shipping: 39.5" W x 42" D x 52.96" H
• Package Type: Crate
Smart® CleanMount® Pass-Through Chambers
Watch Terra's Smart Pass-Through Video
Watch Terra's CleanMount® Pass-Throughs and Racks Video
Smart® Pass-Through Chambers by Terra Universal
Smart® Pass-Through with “T” Shape 3-Door Design for USP 800 Hazardous Compounding
Refrigerated Smart® Passthrough with 90 Degree Corner to Transfer Active Pharmaceutical Ingredients
Smart Cleanroom Pass-Through with 90 Degree Corner and HEPA Filtration
Hands-Free, Automatic Pass-Through Door
Smart Pass-Through Chamber, 24"W x 24"D x 24"H
Fire-Rated Passthrough Chamber with Window
Automatic Door with Touchless Sensor
Vertically Stacked Smart® Passthrough Chambers with HEPA Filtration on Top for Stem Cell Lab
Smart Passthroughs have an electronic interlock and are double-walled, tripling product lifespan and eliminating cleaning value-added accessories.Watch Terra's Smart Pass-Through VideoCleanroom passthrough with smart control system reduces foot traffic, improve cleanliness, safety, productivity and much more. Hidden electronic interlock allows only one door to open at a time to prevent cross-contamination.
Animation detailing installation and operation for Terra's CleanMount® pass-throughs and racksWatch Terra's CleanMount® Pass-Throughs and Racks VideoAnimation detailing installation and operation for Terra's CleanMount® pass-throughs and racks
Terra Universal’s Smart Pass-Through Chamber redefines the capabilities of a pass through by solving a host of challenges that hospitals and labs face every daySmart® Pass-Through Chambers by Terra UniversalTerra Universal’s Smart Pass-Through Chamber redefines the capabilities of a pass through by solving a host of challenges that hospitals and labs face every day. When first introduced to the market, the pass through chamber had one-specific purpose: to reduce personnel traffic by providing a convenient means for sample transfer into and out of the cleanroom. With the Smart Pass Through, Terra has reimagined the jobs a pass through can perform by offering a menu of standard, add-on features compatible with every unit. These features are mounted external to the work area, so the integrity of the internal chamber is not impacted. Beyond sample transfer, the Smart Pass Through can disinfect products, log environmental conditions, track personnel or sample lots, streamline employee communication and add layers of security to your cleanroom.
Smart® pass-through with “T” shape 3-door design, for USP 800 hazardous compounding; interconnects chemo room, USP 800 room, and ante room | 2635-10B-2-316 displayedSmart® Pass-Through with “T” Shape 3-Door Design for USP 800 Hazardous CompoundingTerra’s Smart® pass-through chambers can be configured as a “T” or “X” shape to connect multiple rooms. This 3-door configuration for an in-patient pharmacy interconnects the USP 800 room (negative pressure), chemo room (negative pressure), and ante room.
Refrigerated Smart® passhthrough chamber with 90 degree corner for transferring active pharmaceutical ingredients into a cleanroom | 2635-10B-2-316 displayedRefrigerated Smart® Passthrough with 90 Degree Corner to Transfer Active Pharmaceutical IngredientsRefrigerated Smart® passhthrough chamber with 90 degree corner for transferring active pharmaceutical ingredients into a cleanroom. The refrigeration system is mounted above the passthrough. The double-wall, insulated chamber boosts thermal efficiency. Electronic interlocking doors allow only one door to open at a time.
Smart cleanroom pass-through for anti-tumor therapy incubation room; 90 degree corner design, electronic interlocking doors, recirculating HEPA filtration | 6705-72 displayedSmart Cleanroom Pass-Through with 90 Degree Corner and HEPA FiltrationSmart cleanroom pass-through chambers feature electronic interlocking doors that allow for countless add-on capabilities, plus special door configurations. This unit is designed for an anti-tumor therapy incubation room. It features a 90 degree corner design with re-circulating HEPA filtration.
This video shows how the hands-free operation of the Automatic Pass-Through Door minimizes the potential for touch contamination.Hands-Free, Automatic Pass-Through DoorThe Automated Pass-Through Door (exclusive to Terra's Smart Pass-Through Chambers) prevents personnel from inadvertantly contaminating their gloves or surfaces around the cleanroom.
Smart Pass-Throughs include audible/visible status alerts to indicate when the opposing door is open (interlock engaged). | 2635-10B-2-316 displayedSmart Pass-Through Chamber, 24"W x 24"D x 24"HSmart Pass-Through Chambers feature 316L stainless steel construction, an electronic interlock, and audio/visual status alerts to indicate when the opposing door is open (interlock engaged).
Fire-rated passthrough chamber carries the UL 10B label for 90-minute fire exposure (suitable for 2-hour fire wall); shown: 24" x 24" x 24 chamber | 2641-12 displayedFire-Rated Passthrough Chamber with WindowFire-Rated Passthrough Chambers feature a fire-rated, glass-ceramic window and self-closing, positive-latching doors filled with 2"-thick fire-rated insulation; carries UL10B label (suitable for 2-hour fire wall rating).
Smart Pass-Through Automatic Door option accommodates hands-free operation protocol in bio-pharmaceutical sterile processes | 2635-60 displayedAutomatic Door with Touchless SensorSmart Pass-Through Automatic Door option accommodates hands-free operation protocol in bio-pharmaceutical sterile processes.
Vertical stacked Smart® passthroughs for stem cell lab with limited wall space; recirculating HEPA filtration on top chamber; sloped top on clean side | 6705-72-316 displayedVertically Stacked Smart® Passthrough Chambers with HEPA Filtration on Top for Stem Cell LabThis vertically stacked passthrough chamber system is designed for a stem cell lab with high ceilings and limited wall space. The integrated recirculating filtration system exceeds USP <797> and <800> standards for sterile drug compounding. a sloped-top on the "clean side" minimizes particle build-up.
Features and Benefits
Durable Double Wall Construction
BioSafe double-wall construction triples unit lifespan and totally eliminates cleaning of accessories
Lift-Off, Non-Shedding Door Hinges
Non-shedding, barrel-type door hinges allow the doors to lift off for thorough cleaning and decontamination (no tools required). Unlike industry standard continuous designs, these hinges comply with strict ISO levels.
Smart® Cleanroom Pass-Through with Full-Glass Doors
Hygienic and damage resistant full tempered glass doors are specifically designed for healthcare, pharmaceutical, and GMP manufacturing applications to help achieve FDA compliance. The outside surface of the tempered glass door is frameless to minimize cracks and crevices where particulates or microbes can colonize.
Wireless Door Alert
Alarm bell rings when its assigned door is open (two bells per chamber); plugs into a standard wall outlet.
Installing conventional passthroughs can be very messy, making it impossible to perform while a cleanroom is operational. Terra’s innovative CleanMount® fastening system changes that, allowing for clean installation without drilling or penetrating the cleanroom wall. Framing a CleanMount® passthrough chamber on a finished cut-out eliminates the need for cleanroom shut-down during installation or service.
Highest Standards For Electronic Components
Terra’s electronic components are designed and built to the highest standards required by defense and semiconductor industries for long-term reliability and protection against damage, injuries, and electrical hazards.
Products Compliant With Your ISO Rating
Provide Terra with your desired ISO rating. We will tailor the product to meet your rating and supply a certificate of compliance appended to your invoice, to be included in your compliance package. All certificates are archived in Terra's system for quick retrieval.
Popular Accessories
For a full list of accessories, select a product then click Choose Accessories on that product page.
Designed to be installed into any pass through. Install these racks within minutes with no special tools. Simply tighten a compression screw. Forgot to order racks before? No problem!
Infrared beams detect objects placed inside the transfer chamber and connect to a remote alarm located up to 200 feet away from the pass through chamber. The crossed red lines depict the non-visible trigger lines between the IR transmitters and receivers.
Provides a timed cycle of 254 nm Ultra-Violet (UV) radiation to neutralize bacteria, viruses and mold spores within line-of-sight of the light fixture.
Stainless steel support brackets are recommended for pass-throughs deeper than 24". Brackets fasten to the wall and the body of the chamber rests upon the horizontal bar; no fasteners are used on the pass-through itself.
304 Stainless Steel Sliding Tray for Cleanroom Pass Through
Securely hold small parts during transfer with this dual-motion sliding tray in corrosion-resistant 304 stainless steel. Tray attaches to sliding runners inside a pass-through to allow full tray extension in both directions for convenient material handling.