Price Checker Manuals QuickQuotes About Terra Contact Us
32 cubic foot upright, 10 cubic foot benchtop
 
58 cubic foot upright

Lunaire Stability/Shelf Life Test Chambers

These Steady State and Food & Drug Stability Chambers from Lunaire provide stable temperature and humidity levels in three chamber sizes: 10, 32 and 58 cubic feet. They are designed to meet ICH (International Committee on Harmonization) general stability conditions for room temperature storage, as well as many other applications:

  • Intermediate storage
  • Curing
  • Accelerated shelf life studies
  • Controlled temperature storage
  • Production processes
  • Clean room/biomedical research testing
  • Burn-in
  • Steady state, reliability and stability testing

Rugged, Durable Construction


All models feature vapor-tight stainless steel chamber interiors. Continuously welded in an inert gas environment to ensure optimal integrity, chambers are reinforced at all critical points, and an optimal combination of fiberglass and polyurethane insulation surrounds the chamber work space to maximize temperature containment while reducing overall cabinet size. A double “P” gasket system ensures optimal door seals. Solid stainless steel shelves are adjustable in three-inch increments and safely support up to 135 pounds each. Both shelves and chamber side-duct walls are removable for easy cleaning.

Horizontal Recirculation System


The horizontal recirculating conditioning stream allows flexibility in shelf-loading patterns. The system conditions air in a plenum above the workspace and discharges it through the right-side duct wall, allowing it to flow horizontally across the shelves and exit the chamber through a left-side duct wall. Individually adjustable airflow ports provide temperature uniformity of ± 0.5°C throughout the chamber.

Temperature is measured by a highly reliable platinum RTD sensor; set point and chamber temperatures are displayed with 0.1°C or 0.1°F resolution. The Watlow 965 controller provides automatic or manual chamber control with digital selection and indication of actual conditions. Dual outputs allow auto-tuning of heating output and process or deviation alarm modes. A high-limit control circuit prevents chamber overheating.

The self-contained refrigeration system uses non-CFC environmentally friendly R-13a refrigerant. The high-efficiency compressor and condensing assembly is top-mounted for easy maintenance.

Humidity System


The unique VaporFlo® humidity system provides digital control in two humidity ranges (see specification table). Humidity is measured by an electronic capacitive sensor that operates without a wet wick or water supply, so the device will not produce humidity as a result of the sensing process. Accuracy is consistent through the entire range with a resolution of 0.1% RH and control to ± 2% RH after stabilization. See performance charts.

Complete line of optional features at TerraUniversal.com:

  • Certificate of Calibration
  • CSA Compliance Package
  • Casters
  • Cobex Chart Recorder
  • Deionizer Cartridge
  • Cabinet and support stand (for benchtop models)
  • Viewing Window
  • Compressed Dry Air Dehumidification System
  • Water Reservoir with Pump (eliminates drain connection)
Temperature/Humidity Range Comparison Between CEO 3 and CEO 4 Models
CEO 3 (No. 5326-12)   CEO 4 (No. 5326-03|
 

Please see Water Quality Requirements below chart before ordering.

CEO 3 Models —

Size
(cu. ft.)
Range:
Temperature/
Humidity
Work Space
(W x D x H)
Exterior
(W x D x H)
Heater
Capacity
Humidifier No. of
Shelves
Weight
(lbs)
10 10º above ambient 28x25x24 34x29x49.5 1.5 kW 1.5kW
0.5GPH
2 400
Voltage Cat.# $/Each
208 - 230V, 60 Hz
3 Wire
5326-00 Login
230 - 240V, 60 Hz
3 Wire
5326-01-220 Login
220V, 50 Hz 5326-02 Login
Size
(cu. ft.)
Range:
Temperature/
Humidity
Work Space
(W x D x H)
Exterior
(W x D x H)
Heater
Capacity
Humidifier No. of
Shelves
Weight
(lbs)
32 to 99ºC  above 33x28x60 69x32x88 2 kW 1.5kW
0.5GPH
4 1150
Voltage Cat.# $/Each
208 - 230V, 60 Hz
3 Wire
5326-06 Login
230 - 240V, 60 Hz
3 Wire
5326-07-220 Login
220V, 50 Hz 5326-08 Login
Size
(cu. ft.)
Range:
Temperature/
Humidity
Work Space
(W x D x H)
Exterior
(W x D x H)
Heater
Capacity
Humidifier No. of
Shelves
Weight
(lbs)
58 ambient to 96% RH 60x28x60 70x32x88 6 kW 3 kW
1.0GPH
8 1700
Voltage Cat.# $/Each
208 - 230V, 60 Hz
3 Wire
5326-12 Login
230 - 240V, 60 Hz
3 Wire
5326-13-220 Login
220V, 50 Hz 5326-14 Login

CEO 4 Models —

Size
(cu. ft.)
Range:
Temperature/
Humidity
Work Space
(W x D x H)
Exterior
(W x D x H)
Heater
Capacity
Humidifier No. of
Shelves
Weight
(lbs)
10 0º to 99ºC 28x25x24 34x29x49.5 1.5 kW 1.5kW
0.5GPH
2 400
Voltage Cat.# $/Each
208 - 230V, 60 Hz
3 Wire
5326-03 Login
230 - 240V, 60 Hz
3 Wire
5326-04-220 Login
220V, 50 Hz 5326-05 Login
Size
(cu. ft.)
Range:
Temperature/
Humidity
Work Space
(W x D x H)
Exterior
(W x D x H)
Heater
Capacity
Humidifier No. of
Shelves
Weight
(lbs)
32 20% to 96% RH 33x28x60 39x32x88 2 kW 1.5kW
0.5GPH
4 1350
Voltage Cat.# $/Each
208 - 230V, 60 Hz
3 Wire
5326-09 Login
230 - 240V, 60 Hz
3 Wire
5326-10-220 Login
220V, 50 Hz 5326-11 Login
Size
(cu. ft.)
Range:
Temperature/
Humidity
Work Space
(W x D x H)
Exterior
(W x D x H)
Heater
Capacity
Humidifier No. of
Shelves
Weight
(lbs)
58 20% to 96% RH 33x28x60 39x32x88 2 kW 1.5kW
0.5GPH
4 1350
Voltage Cat.# $/Each
208 - 230V, 60 Hz
3 Wire
5326-15 Login
230 - 240V, 60 Hz
3 Wire
5326-16-220 Login
220V 50 Hz, 3 Wire 5326-17 Login

Water Quality Requirements for Humidified Chambers
(Particularly applicable to T2RC and CEO models)

  • It is strongly recommended that you have your water supply tested for resistivity, as well as, organic and inorganic content before using the humidity system.
  • The water supply to the humidty system must be demineralized or single distilled, and have a resistance measurement between 50,000 and 100,000 Ohm/cm (20 to 10 Microsiemens/cm). It is important that the water is very low in minerals. Otherwise, the system will become encrusted with minerals and cause system failure. If your supply water cannot meet the resistivity specifications, a cartridge ion exchanger should be obtained from through Terra Universal.
  • Do not use double or triple distilled (ultra-pure) water. Pure water (greater than 1.0 Megohm/cm) will attack metals such as copper, brass, etc., and will drastically reduce the life of the humidity system.
  • Never supply demineralized, or single distilled water to a Cartridge De-ionizer. (The result is double distiller water.)
  • If your water supply test show that appreciable amounts of suspended particles are present, either a 5 micron or 25 micron polypropylene pre-filter should be installed. This filter may be needed in addition to an ion exchanger.  All filter types can be obtained through Terra Universal.
  • If your water supply test show that appreciable amounts of organic, free chlorine and chloramines, phosphate complexes and turbidity are present, a roughing filter (US Filter Model: Absorber) should be used. This filter may be needed in addition to an ion exchanger. All filter types can be obtained through Terra Universal.
  • Due to periodic changes that could occur in the quality of city or well water supplies, you should check the water supply for resistivity and organic / inorganic content every one (1) to two (2) months.

Accessories for your Lunaire Stability Test Chamber  

*Standard location is centered right side, specify alternate location Cat.# $/Each
Shelves, Stainless Steel for 10 CF Chamber 5326-20 Login
Shelves, Stainless Steel for 32 CF Chamber 5326-21 Login
Shelves, Stainless Steel for 58 CF Chamber 5326-22 Login
Certificate of Calibration 5325-47 Login
Additional Access Port* 5326-23 Login
CSA Compliance Package 5326-24 Login
Crating-Export for 10 CF Chamber 5326-25 Login
Crating-Export for 32 CF Chamber 5326-26 Login
Crating-Export for 58 CF Chamber 5326-27 Login
Cabinet for 10 CF Chamber 5326-28 Login
Casters, Set of 4 (2 locking) 5326-29 Login
Recorder in Temperature, Cobex in °C 5326-30 Login
Recorder, Honeywell Dr4300, 2 Pen 10" Circular Chart - specify temp range & 24 hr or 7 Day 5326-32 Login
Chart Paper, 2 Pen, 24 Hour 5326-52 Login
Chart Paper, 2 Pen, 7 Day 5326-53 Login
Inner Door, Nonsealed, 2 panel for 10 CF Chamber 5326-33 Login
Inner Door, Nonsealed, 2 panel for 32 CF Chamber 5326-34 Login
Inner Door, Nonsealed, 2 panel for 58 CF Chamber 5326-35 Login
Interior Receptacle, Vapor-Proof Duplex 5326-36 Login
Software, LinkTenn 32 5326-26 Login
Viewing Window, 18" x 18" For 10 CF Chamber 5326-40 Login
Viewing Window, 17" x 47" For 32 CF Chamber 5326-41 Login
Viewing Window, 17" x 47" For 58 CF Chamber 5326-42 Login
Compressed Dry Air Dehumidification System for 10 CF and 32 CF Chamber 5326-43 Login
Compressed Dry Air Dehumidification System for 58 CF Chamber 5326-44 Login
NAFTA Certificate 5326-20 Login
Deionizer Cartridge-Double 5326-45 Login
Deionizer Cartridge-Single 5326-46 Login
Water Condensate Pump 5326-47 Login
Water Reservoir-22 Qt. for 10 & 32 CF Chamber 5326-48 Login
Water Reservoir-5 Gal for 58 CF Chamber 5326-49 Login
Water Reservoir with Pump - 22 Qt 5326-50 Login
Water Reservoir with Pump - 5 Gal 5326-51 Login
*Standard location is centered right side, specify alternate location
Preferred Client
Services Include:
QuickStart Manuals
Price Checker
Update Profile
You are not logged in.
Type email address and click Login.
Product Selection


Vacuum & Environmental Chambers
Vacuum Chambers
Test Chambers
Tenney Jr. Benchtop & Upright Test Chambers
Tenney 2 Temp. & Humidity Test Chambers
Lunaire Stability Test Chambers
Environmental Chambers

All prices and specifications are subject to change without notice. Crating charges apply to selected items.
  Terms and Conditions
  Precision Fabrication to Your Specs! Call to discuss your requirements for CNC routing and drilling.
  Top of page