| 32 cubic foot upright, 10 cubic foot benchtop |
| |
 |
| 58 cubic foot upright |
Lunaire Stability/Shelf Life Test Chambers
These Steady State and Food & Drug Stability Chambers from Lunaire provide stable temperature and humidity levels in three chamber sizes: 10, 32 and 58 cubic feet. They are designed to meet ICH (International Committee on Harmonization) general stability conditions for room temperature storage, as well as many other applications:
- Intermediate storage
- Curing
- Accelerated shelf life studies
- Controlled temperature storage
- Production processes
- Clean room/biomedical research testing
- Burn-in
- Steady state, reliability and stability testing
Rugged, Durable Construction
All models feature vapor-tight stainless steel chamber interiors. Continuously welded in an inert gas environment to ensure optimal integrity, chambers are reinforced at all critical points, and an optimal combination of fiberglass and polyurethane insulation surrounds the chamber work space to maximize temperature containment while reducing overall cabinet size. A double “P” gasket system ensures optimal door seals. Solid stainless steel shelves are adjustable in three-inch increments and safely support up to 135 pounds each. Both shelves and chamber side-duct walls are removable for easy cleaning.
Horizontal Recirculation System
The horizontal recirculating conditioning stream allows flexibility in shelf-loading patterns. The system conditions air in a plenum above the workspace and discharges it through the right-side duct wall, allowing it to flow horizontally across the shelves and exit the chamber through a left-side duct wall. Individually adjustable airflow ports provide temperature uniformity of ± 0.5°C throughout the chamber.
Temperature is measured by a highly reliable platinum RTD sensor; set point and chamber temperatures are displayed with 0.1°C or 0.1°F resolution. The Watlow 965 controller provides automatic or manual chamber control with digital selection and indication of actual conditions. Dual outputs allow auto-tuning of heating output and process or deviation alarm modes. A high-limit control circuit prevents chamber overheating.
The self-contained refrigeration system uses non-CFC environmentally friendly R-13a refrigerant. The high-efficiency compressor and condensing assembly is top-mounted for easy maintenance.
Humidity System
The unique VaporFlo® humidity system provides digital control in two humidity ranges (see specification table). Humidity is measured by an electronic capacitive sensor that operates without a wet wick or water supply, so the device will not produce humidity as a result of the sensing process. Accuracy is consistent through the entire range with a resolution of 0.1% RH and control to ± 2% RH after stabilization. See performance charts.
Complete line of optional features at TerraUniversal.com:
-
Certificate of Calibration
- CSA Compliance Package
- Casters
- Cobex Chart Recorder
- Deionizer Cartridge
- Cabinet and support stand (for benchtop models)
- Viewing Window
- Compressed Dry Air Dehumidification System
- Water Reservoir with Pump (eliminates drain connection)
|
| Temperature/Humidity Range Comparison Between CEO 3 and CEO 4 Models |
| CEO 3 (No. 5326-12) |
|
CEO 4 (No. 5326-03| |
 |
|
 |
|
Please see Water Quality Requirements below chart before ordering.
CEO 3 Models —
Size
(cu. ft.) |
Range:
Temperature/
Humidity |
Work Space
(W x D x H) |
Exterior
(W x D x H) |
Heater
Capacity |
Humidifier |
No. of
Shelves |
Weight
(lbs) |
| 10 |
10º above ambient |
28x25x24 |
34x29x49.5 |
1.5 kW |
1.5kW
0.5GPH |
2 |
400 |
| Voltage |
Cat.# |
$/Each |
208 - 230V, 60 Hz
3 Wire |
5326-00 |
Login |
230 - 240V, 60 Hz
3 Wire |
5326-01-220 |
Login |
| 220V, 50 Hz |
5326-02 |
Login |
Size
(cu. ft.) |
Range:
Temperature/
Humidity |
Work Space
(W x D x H) |
Exterior
(W x D x H) |
Heater
Capacity |
Humidifier |
No. of
Shelves |
Weight
(lbs) |
| 32 |
to 99ºC above |
33x28x60 |
69x32x88 |
2 kW |
1.5kW
0.5GPH |
4 |
1150 |
| Voltage |
Cat.# |
$/Each |
208 - 230V, 60 Hz
3 Wire |
5326-06 |
Login |
230 - 240V, 60 Hz
3 Wire |
5326-07-220 |
Login |
| 220V, 50 Hz |
5326-08 |
Login |
Size
(cu. ft.) |
Range:
Temperature/
Humidity |
Work Space
(W x D x H) |
Exterior
(W x D x H) |
Heater
Capacity |
Humidifier |
No. of
Shelves |
Weight
(lbs) |
| 58 |
ambient to 96% RH |
60x28x60 |
70x32x88 |
6 kW |
3 kW
1.0GPH |
8 |
1700 |
| Voltage |
Cat.# |
$/Each |
208 - 230V, 60 Hz
3 Wire |
5326-12 |
Login |
230 - 240V, 60 Hz
3 Wire |
5326-13-220 |
Login |
| 220V, 50 Hz |
5326-14 |
Login |
CEO 4 Models —
Size
(cu. ft.) |
Range:
Temperature/
Humidity |
Work Space
(W x D x H) |
Exterior
(W x D x H) |
Heater
Capacity |
Humidifier |
No. of
Shelves |
Weight
(lbs) |
| 10 |
0º to 99ºC |
28x25x24 |
34x29x49.5 |
1.5 kW |
1.5kW
0.5GPH |
2 |
400 |
| Voltage |
Cat.# |
$/Each |
208 - 230V, 60 Hz
3 Wire |
5326-03 |
Login |
230 - 240V, 60 Hz
3 Wire |
5326-04-220 |
Login |
| 220V, 50 Hz |
5326-05 |
Login |
Size
(cu. ft.) |
Range:
Temperature/
Humidity |
Work Space
(W x D x H) |
Exterior
(W x D x H) |
Heater
Capacity |
Humidifier |
No. of
Shelves |
Weight
(lbs) |
| 32 |
20% to 96% RH |
33x28x60 |
39x32x88 |
2 kW |
1.5kW
0.5GPH |
4 |
1350 |
| Voltage |
Cat.# |
$/Each |
208 - 230V, 60 Hz
3 Wire |
5326-09 |
Login |
230 - 240V, 60 Hz
3 Wire |
5326-10-220 |
Login |
| 220V, 50 Hz |
5326-11 |
Login |
Size
(cu. ft.) |
Range:
Temperature/
Humidity |
Work Space
(W x D x H) |
Exterior
(W x D x H) |
Heater
Capacity |
Humidifier |
No. of
Shelves |
Weight
(lbs) |
| 58 |
20% to 96% RH |
33x28x60 |
39x32x88 |
2 kW |
1.5kW
0.5GPH |
4 |
1350 |
| Voltage |
Cat.# |
$/Each |
208 - 230V, 60 Hz
3 Wire |
5326-15 |
Login |
230 - 240V, 60 Hz
3 Wire |
5326-16-220 |
Login |
| 220V 50 Hz, 3 Wire |
5326-17 |
Login |
|
|
Water Quality Requirements for Humidified Chambers
(Particularly applicable to T2RC and CEO models)
- It is strongly recommended that you have your water supply tested for resistivity, as well as, organic and inorganic content before using the humidity system.
- The water supply to the humidty system must be demineralized or single distilled, and have a resistance measurement between 50,000 and 100,000 Ohm/cm (20 to 10 Microsiemens/cm). It is important that the water is very low in minerals. Otherwise, the system will become encrusted with minerals and cause system failure. If your supply water cannot meet the resistivity specifications, a cartridge ion exchanger should be obtained from through Terra Universal.
- Do not use double or triple distilled (ultra-pure) water. Pure water (greater than 1.0 Megohm/cm) will attack metals such as copper, brass, etc., and will drastically reduce the life of the humidity system.
- Never supply demineralized, or single distilled water to a Cartridge De-ionizer. (The result is double distiller water.)
- If your water supply test show that appreciable amounts of suspended particles are present, either a 5 micron or 25 micron polypropylene pre-filter should be installed. This filter may be needed in addition to an ion exchanger. All filter types can be obtained through Terra Universal.
- If your water supply test show that appreciable amounts of organic, free chlorine and chloramines, phosphate complexes and turbidity are present, a roughing filter (US Filter Model: Absorber) should be used. This filter may be needed in addition to an ion exchanger. All filter types can be obtained through Terra Universal.
- Due to periodic changes that could occur in the quality of city or well water supplies, you should check the water supply for resistivity and organic / inorganic content every one (1) to two (2) months.
|
Accessories for your Lunaire Stability Test Chamber
| *Standard location is centered right side, specify alternate location |
Cat.# |
$/Each |
| Shelves, Stainless Steel for 10 CF Chamber |
5326-20 |
Login |
| Shelves, Stainless Steel for 32 CF Chamber |
5326-21 |
Login |
| Shelves, Stainless Steel for 58 CF Chamber |
5326-22 |
Login |
| Certificate of Calibration |
5325-47 |
Login |
| Additional Access Port* |
5326-23 |
Login |
| CSA Compliance Package |
5326-24 |
Login |
| Crating-Export for 10 CF Chamber |
5326-25 |
Login |
| Crating-Export for 32 CF Chamber |
5326-26 |
Login |
| Crating-Export for 58 CF Chamber |
5326-27 |
Login |
| Cabinet for 10 CF Chamber |
5326-28 |
Login |
| Casters, Set of 4 (2 locking) |
5326-29 |
Login |
| Recorder in Temperature, Cobex in °C |
5326-30 |
Login |
| Recorder, Honeywell Dr4300, 2 Pen 10" Circular Chart - specify temp range & 24 hr or 7 Day |
5326-32 |
Login |
| Chart Paper, 2 Pen, 24 Hour |
5326-52 |
Login |
| Chart Paper, 2 Pen, 7 Day |
5326-53 |
Login |
| Inner Door, Nonsealed, 2 panel for 10 CF Chamber |
5326-33 |
Login |
| Inner Door, Nonsealed, 2 panel for 32 CF Chamber |
5326-34 |
Login |
| Inner Door, Nonsealed, 2 panel for 58 CF Chamber |
5326-35 |
Login |
| Interior Receptacle, Vapor-Proof Duplex |
5326-36 |
Login |
| Software, LinkTenn 32 |
5326-26 |
Login |
| Viewing Window, 18" x 18" For 10 CF Chamber |
5326-40 |
Login |
| Viewing Window, 17" x 47" For 32 CF Chamber |
5326-41 |
Login |
| Viewing Window, 17" x 47" For 58 CF Chamber |
5326-42 |
Login |
| Compressed Dry Air Dehumidification System for 10 CF and 32 CF Chamber |
5326-43 |
Login |
| Compressed Dry Air Dehumidification System for 58 CF Chamber |
5326-44 |
Login |
| NAFTA Certificate |
5326-20 |
Login |
| Deionizer Cartridge-Double |
5326-45 |
Login |
| Deionizer Cartridge-Single |
5326-46 |
Login |
| Water Condensate Pump |
5326-47 |
Login |
| Water Reservoir-22 Qt. for 10 & 32 CF Chamber |
5326-48 |
Login |
| Water Reservoir-5 Gal for 58 CF Chamber |
5326-49 |
Login |
| Water Reservoir with Pump - 22 Qt |
5326-50 |
Login |
| Water Reservoir with Pump - 5 Gal |
5326-51 |
Login |
*Standard location is centered right side, specify alternate location |
|
|
|