Cleanroom — Gowning Room Design that Terra Recommends

Terra Universal will certify its cleanrooms to guarantee “as built” compliance with cleanliness standards. What matters, though, is how the cleanroom performs in real world applications—in your application, with your personnel and processing equipment.

Careful consideration of these operating conditions will help you select the configuration that meets your requirements and fits your budget!


Cost vs. Coverage: Evaluating FFU Placement
The cleanest modular cleanroom incorporates filter/fan units (FFUs) in every 2' x 4' ceiling bay. This near-100% ceiling coverage provides a laminar flow of filtered air to quickly remove contaminants from the cleanroom, meeting Federal Standard 209(E) for Class 10 or Class 1 environment (depending on the filter types selected, HEPA or ULPA).

Of course , 100% ceiling coverage requires substantial investment in FFUs, especially if the cleanroom is very large. In most applications, adequate cleanliness can be achieved with substantially less filter coverage. How many modules you need depends on several operational variables.


Cleanliness Rating
Most cleanroom facility engineers agree that Class 1 and Class 10 applications require near-100% ceiling coverage, producing a laminar flow of clean air traveling downward at a velocity of about 90 feet/minute (measured 12" below the filter face). This design ensures a positive pressure inside the cleanroom, which blocks the influx of contaminants through leaks in the cleanroom wall or curtain, and guarantees swift removal of particles generated by people or process equipment inside the enclosure.

Table 1:
Recommended Air Velocity Rates
Class
Iso 146144-1
(Standard 209E)
Average Airflow Velocity Air Changes
Per Hour
ISO 8 (Class 100,000) 0.005 - 0.041 m/sec (1 - 8 ft/min) 5 - 48
ISO 7 (Class 10,000) 0.051 - 0.076 m/sec (10 - 15 ft/min) 60 - 90
ISO 6 (Class 1,000) 0.127 - 0.203 m/sec (25 - 40 ft/min) 150 - 240
ISO 5 (Class 100) 0.203 - 0.406 m/sec (40 - 80 ft/min) 240 - 480
ISO 4 (Class 10) 0.254 - 0.457 m/sec (50 - 90 ft/min) 300 - 540
ISO 3 (Class 1) 0.305 - 0.457 m/sec (60 - 90 ft/min) 360 - 540
ISO 1-2 0.305 - 0.508 m/sec (60 - 100 ft/min) 360 - 600
Note: Actual average velocity and air changes required may vary depending on the application and floor plan. Source: Institute of Environmental Science
Table 2:
Recommended Ceiling Filter Coverage
Class Ceiling Coverage
ISO 8 (Class 100,000) 5 - 15%
ISO 7 (Class 10,000) 15 - 20%
ISO 6 (Class 1,000) 25 - 40%
ISO 5 (Class 100) 35 - 70%
ISO 4 (Class 10) 50 - 90%
ISO 3 (Class 1) 60 - 100%*
ISO 1-2 80 - 100%*
Note: Actual average velocity and air changes required may vary depending on the application and floor plan.
* ULPA filters required in Class 1/10 applications. HEPA filters required for all others.
Ventilation Efficiency
For less critical contamination requirements, experts correlate ventilation efficiency (i.e., the ability to remove contaminants and meet a cleanliness standard) with both the velocity of filtered air passing through the room and also the number of air changes completed in a given time. The air-change figures are usually expressed as a range
(see Table 1).

The breadth of these ranges reflects how dramatically people and processes affect cleanliness. Low-end figures within each contamination class generally indicate air velocity and air change requirements for an "as built" or "at rest" facility—one in which no people are present and no contaminating processes are under way. In the presence of higher degrees of contamination (resulting from many cleanroom workers or contaminating manufacturing processes), more air changes are required to maintain the desired cleanliness standard. In fact, many manufacturers insist on as many as 720 air changes per hour to meet Class 10 or cleaner requirements.

Deciding on the appropriate velocity and air changes for your application generally requires careful evaluation of such factors as number of personnel, effectiveness of garbing protocol, frequency of access, and cleanliness of process equipment. Once you have established the required air change figure, you can calculate the number of FFUs required by using this formula:
No. of FFUs = (Air Changes/Hour ÷60) x (Cubic ft. in room÷ 650*)
*CFM output of a loaded FFU

Thus, to meet Class 100 standard using the low-end air change recommendation (240/hour) inside a 12' x 12' x 7' cleanroom, with 1008 cu. ft. of volume, requires 6 FFUs. To meet the same standard using the high-end air change recommendation (480/hour) requires 12 FFUs.

Applying this formula to the remaining cleanliness classifications gives us guidelines for ceiling filter coverage (see Table 2).


modular cleanrooms

Typical Configurations Using Partitions

Zone 1:
Most Particle Sensitive. Class 1 (ULPA) or (HEPA) 100% Filter Coverage
Zone 2:
Packaging Area. Class 100 50% Filter coverage
Zone 3:
Staging Area Class 1,000 30% Coverage
Note: These are typical, not guaranteed, contamination levels for each of the filter configurations depicted. Actual values are related to such variables as the number of garbed personnel present, their activity level, the cleanliness of outside air, and contaminants emanating from process equipment.
Partitions: Creating "Clean Zones" to Optimize Performance and Economy
Of course, not every square inch of cleanroom space is used the same way. Often, performance can be optimized—and costs reduced—through the use of partitions to create multiple clean zones with varying degrees of cleanliness.

As requirements change, partitions can be removed and filter modules added or rearranged as needed. Highest ceiling filter density can be reserved for areas with the cleanest requirements and the most particles generated. Areas with fewer people or less demanding particle requirements are configured more economically with fewer filters.

Your Best Approach?
Thorough Evaluation and Careful Monitoring
Because no simple formula is right for every application, Terra contamination specialists work with you to design an effective, economical cleanroom configuration and monitoring program. If requirements change, our modular design allows you to add filters, lighting, ionization, or additional floor space—all at a fraction of the cost you'd face with other systems.

 


Cleanroom Lighting
Terra offers three lighting modules.

For applications that do not require 100% FFU ceiling coverage, 2' x 4' illuminators can be positioned in unused ceiling grids.

For applications that require total or near-total FFU ceiling coverage, teardrop and flow-through lighting modules are available. Teardrop fluorescent lights mount to the ceiling grid below the FFU. Their aerodynamic design does not interfere with the laminar airflow. Each of these single-tube lights requires 6" of vertical clearance below the FFU filter face.

As an alternative to teardrop lights, you can select 2' x 4' flow-through lights, which are stacked below the FFU. Flow-through lights add 43?4" to the ceiling height but require no vertical clearance below the filter face, making them ideal for low-ceiling cleanrooms.

Use these guidelines in selecting the appropriate number of lighting modules for your application:
Light Level Viewing Requirements Foot-Candles/Sq. Ft
Dim Large Part Sizes, High Contrast 20 - 50
Average Small Part Sizes, Medium Contrast 100 - 200
Bright Small Part Sizes, Low Contrast 200 - 500
No. of Fixtures
  = (Desired foot-candles/sq. ft. x Room Area) ÷ 4560 (for 2' x 4' lights)
  = (Desired foot-candles/sq. ft. x Room Area) ÷ 1260 (for teardrop lights)
  = (Desired foot-candles/sq. ft. x Room Area) ÷ 3150 (for flow-through lights)
 
Preferred Client
Services Include:
QuickStart Manuals
Price Checker
Update Profile
You are not logged in.
Type email address and click Login.
Request a Quote
The QuickQuote planning form makes it easy to specify the system for your requirements
Product Selection


Modular Cleanrooms
Section Resources
Modular Cleanroom Designs
Cleanroom Furnishings
Garb Parts & Dispensers
Application Guidelines


All prices and specifications are subject to change without notice. Crating charges apply to selected items.
  Terms and Conditions
  Precision Fabrication to Your Specs! Call to discuss your requirements for CNC routing and drilling.
  Top of page
Cleaning Service Referral
 
A person in clean room suit is cleaning and sterilizing a room
 

Certification and Compliance
ISO 14644 particle count, FDA, cGMP, USP <797>
Terra understands the performance criteria you face for certification and designs your system accordingly. We arrange third-party certifications, cleanroom audits, compliance training and SOP development, including viable and non-viable particle monitoring.

 
Cleaning and Sterilization Services
In select regions, we arrange ongoing cleaning and sterilization programs, using ISO-certified micro-cleaning specialists working to the most rigorous cleanliness standards. Call to discuss your requirements.
 