| Shown with optional motorized shield |
 |
 |

|
 |
PLC provides convenient touchscreen control of light,
shield and blower(s). |
Strip shield access curtain (optional) |
|
Vertical Laminar Flow Stations
- Economical system provides a laminar flow of HEPA-filtered
air to meet the most critical contamination requirements
- Incorporates industry-leading 50 dBA blowers for
quiet, low-vibration operation
- All-stainless steel construction is cleanroom compatible
and easy to clean
- Wet station VLF includes polypropylene rear panel for
chemical resistance
- Side panels and optional front sliding shield effectively
control the laminar air stream to achieve the air speed
you require
- Fluorescent illuminators ensure easy viewing
- Optional ionization equipment safely neutralizes static
charges throughout the work area for effective ESD protection
-
Accommodates standard Terra
work benches in many materials, as well as standard Terra
wet processing stations
Terra Universal's Vertical Laminar Flow Station combines several
of our most advanced products in a state-of-the-art work station
that removes particulate air-borne contamination.
The backbone of the system is the reliable Filter/Fan Unit
(FFU), which provides a flow of microfiltered air to meet cleanliness
standards.
Patented baffling technology ensures uniform airflow across
the filter face and attenuates sound for the lowest noise level
in the industry: approximately 50 dBA (see "Specifications"
below). Select the HEPA (High Efficiency Particulate Air) filter,
rated 99.99% efficient removing 0.3-micron particles. Each unit
includes a high/low adjustment switch.
Tests show that the work station exceeds Federal Standard 209E
for a Class 100/ISO 5 work environment with HEPA filter.
Side and Front Panels Let You Control
Laminar Flow
The Vertical Laminar Flow Station comes complete with transparent
acrylic side panels that restrict the laminar flow and ensure
an effective wash of HEPA filtered air over the entire work
surface.
For additional control of the laminar flow, select
the Sliding Shield, which can be adjusted up or down along
the front of the access area to the level you require. This
feature allows you to control the force of the laminar flow
to accommodate your application: stronger flows ensure optimal
cleanliness; and weaker flows reduce turbulence that might
disturb small parts.
The Sliding Shield is made of Static-Dissipative PVC, a transparent
material that features a surface resistivity of about 107
ohms/square. This static-dissipating characteristic eliminates
not only static charges that can damage sensitive components,
but also the particles that static charges attract. As a result,
the sliding shield remains cleaninside and out. Note:
To ensure optimal static and contamination protection, Terra
recommends that you select side panels made of Static-Dissipative
PVC if you select the sliding shield option; see ordering
table.
VLF stations are available with work surfaces that accommodate
every application. The standard work surface is a nonconductive
laminate top sealed on all sides to meet cleanroom requirements.
Others are available with tops made of dissipative laminate,
304 stainless steel, and polypropylene.
For delicate microscope operations, select the Vibration-Free
Work Station, which eliminates up to 90% of all building
vibrations to ensure a steady work surface.
Static Control
A 4" space under the HEPA filter accommodates
optional ionizing equipment for complete static safety.
An ionizing bar houses nozzles that emit
balanced streams of positive and negative ions downward
to safely neutralize any static imbalances that may exist
in the work area.
 |
Operation with Terra Wet Processing
Station
The Vertical Laminar Flow Station is completely
compatible with Terra's Wet Processing Station.
When operated together, these stations form an integrated
processing system that accepts a host of wet processing
modules to accommodate your applications.
Rear panel is made of polypropylene both for
chemical resistance and to facilitate easier cut-outs
for exhaust and other plumbing.
Terra Wet Processing
Station
positioned beneath a Vertical Laminar Flow Hood
VLF Stations
for Wet Station with polypropylene rear panel.
|
|

Optional shield retracts 3" - 25" below hood |
Ordering Information
Order the Vertical Laminar Flow Station,
Filter/Fan Units (FFUs), and other optional accessories
separately from the charts below. Selected accessories
are installed in the corresponding Vertical Laminar
Flow Station and shipped as a turnkey system, ready
for operation. |
> |

Cleanroom
Drawers
available in
ABS Plastic and
Stainless Steel. |
|
|
Stainless
Steel Vertical Laminar Flow Station |
Side
Panel* |
Sliding
Shield |
Dimensions
(inches) |
No.
of FFUs
required |
304 Stainless
Steel |
Static-Dissipative
PVC
|
Static-Dissipative
PVC  |
| 120VAC,
50/60Hz |
220VAC,
50Hz |
| A |
B |
C
x D |
(order
above) |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
| 52 |
49 |
48
x 30 |
(1)
2' x 4' |
2001-30A |
Login |
2001-30A-220 |
Login |
2004-03 |
Login |
9207-04 |
Login |
| 64 |
61 |
60
x 30 |
(1)
2' x 2' + (1) 2' x 3' |
2001-31A |
Login |
2001-31A-220 |
Login |
2004-03 |
Login |
9207-05 |
Login |
| 76 |
73 |
72
x 30 |
(2)
2' x 3' |
2001-32A |
Login |
2001-32A-220 |
Login |
2004-03 |
Login |
9207-06 |
Login |
| 100 |
97 |
96
x 30 |
(2)
2' x 4' |
2001-33A |
Login |
2001-33A-220 |
Login |
2004-03 |
Login |
9207-07 |
Login |
*Replaces standard Plexiglas side
panels (each station requires two). Static-Dissipative PVC is
recommended on units
equipped with optional dissipative sliding shield.
|
Powder
Coated Steel Vertical Laminar Flow Station |
Side
Panel* |
Sliding
Shield |
Dimensions
(inches) |
No.
of FFUs
required |
Powder
Coated Steel |
Static-Dissipative
PVC
|
Static-Dissipative
PVC  |
| 120VAC,
50/60Hz |
220VAC,
50Hz |
| A |
B |
C
x D |
(order
above) |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
| 52 |
49 |
48
x 30 |
(1)
2' x 4' |
2001-80A |
Login |
2001-80A-220 |
Login |
2004-03 |
Login
|
9207-04 |
Login |
| 64 |
61 |
60
x 30 |
(1)
2' x 2' + (1) 2' x 3' |
2001-81A |
Login |
2001-81A-220 |
Login |
2004-03 |
Login
|
9207-05 |
Login |
| 76 |
73 |
72
x 30 |
(2)
2' x 3' |
2001-82A |
Login |
2001-82A-220 |
Login |
2004-03 |
Login
|
9207-06 |
Login |
| 100 |
97 |
96
x 30 |
(2)
2' x 4' |
2001-83A |
Login |
2001-83A-220 |
Login |
2004-03 |
Login
|
9207-07 |
Login |
*Replaces standard Plexiglas side
panels (each station requires two). Static-Dissipative PVC is
recommended on units
equipped with optional dissipative sliding shield.
| Corresponding
Solid Top Work Benches |
Dimensions
(inches) |
Nonconductive
Laminate
Top |
Conductive
Laminate
Top
 |
304 Stainless
Steel
Top |
Polypropylene
Top |
| A |
B |
C
x D |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
| 52 |
49 |
48
x 30 |
1722-00 |
Login |
1728-00 |
Login |
1521-45 |
Login |
1522-00 |
Login |
| 64 |
61 |
60
x 30 |
1724-00 |
Login |
1730-00 |
Login |
1751-00 |
Login |
1522-01 |
Login |
| 76 |
73 |
72
x 30 |
1726-00 |
Login |
1732-00 |
Login |
1752-00 |
Login |
1522-02 |
Login |
| 100 |
97 |
96
x 30 |
2402-00 |
Login |
2400-00 |
Login |
1753-00 |
Login |
1522-04 |
Login |
| Corresponding
Perforated Top Work Benches |
Dimensions
(inches) |
304 Stainless
Steel Top |
304 Stainless
Steel Top
(Polypropylene Plenum)  |
| A |
B |
C
x D |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
| 52 |
49 |
48
x 30 |
1522-56 |
Login |
1526-50 |
Login |
| 64 |
61 |
60
x 30 |
1522-57 |
Login |
1526-51 |
Login |
| 76 |
73 |
72
x 30 |
1522-58 |
Login |
1526-52 |
Login |
| 100 |
97 |
96
x 30 |
1522-60 |
Login |
1526-54 |
Login |
| Filter Fan Units |
| Model |
Avg. CFM
CFM
(m3/hr) |
Power |
With
HEPA Filter |
With
ULPA Filter |
| Cat. # |
$/Each |
Cat. # |
$/Each |
| 48" x 24" |
644
(1095) |
120VAC, 50/60Hz
220VAC, 50Hz |
6701-99A |
Login
|
6702-01A |
Login
|
|
6701-99A-220 |
Login
|
6702-01A-220 |
Login
|
| 36" x 24" |
477
(811) |
120VAC, 50/60Hz
220VAC, 50Hz |
6702-08A |
Login
|
6702-12A |
Login
|
|
6702-08A-220 |
Login
|
6702-12A-220 |
Login
|
| 24" x 24" |
310
(527) |
120VAC, 50/60Hz
220VAC, 50Hz |
6702-10A |
Login
|
6702-13A |
Login
|
|
6702-10A-220 |
Login
|
6702-13A-220 |
Login
|
| Specifications |
| General Construction: |
Fabricated of 1.5" x 3" 304 stainless steel
members. FFUs encased in 304 stainless steel overhead housing.
Base includes 1" stainless steel leveling feet. |
| Rear Panel: |
Extends from hood to benchtop height (31"
above floor) to optimize laminar flow.
Stainless steel VLF has stainless steel rear panel.
Powder coated VLF has powder coated rear panel.
VLF for wet station has polypropylene rear panel. |
| Side Panels: |
29"D x 32"H acrylic (static-dissipative PVC available) |
| Prefilters: |
Washable polyurethane foam, located at top of FFUs |
| Final Filters: |
99.99% efficient HEPA (rated @ 0.3µm particles) |
| Fan Motor: |
Direct drive, forward curve, centrifugal-type
with sealed bearings; rated for continuous duty; furnished
with overload protection and a two-speed switch. Rated
.25 HP @ low speed; .333 HP @
high speed (2' x 4' models) |
| Average airflow velocity: |
90 (± 10) FPM (.45 m/sec) at low speed,
measured 6" below filter face |
| FFU Air Flow: |
650 (2' x 4'); 480 (2' x 3'); 360 (2' x 22')
- all models rated @ 90 FPM under HEPA filter load |
| Sound level: |
50 dBA, measured no more than 30" from filter
face @ 90 FPM |
| Vibration level: |
0.09 MILS |
| FFU housing: |
0.63-inch thick aluminum with mill finish;
includes integral air baffle system to ensure even air
distribution. FFU fully encased in 304 stainless steel housing. |
| Lighting: |
| Fluorescent, 100 foot-candles. Does not disturb
the air flow. |
| Electrical: |
110VAC, 50/60Hz or 220VAC, 50 Hz. Meets the
requirements of the National Electrical Code and applicable
local codes. All components UL listed and CE marked. |
| Performance: |
Dust count exceeds Class 10 requirements. |
| Installation: |
System is shipped as turnkey system; no installation
required. |
|