MAGNEHELIC®, PHOTOHELIC®, MINIHELIC®, and DIGIHELIC®
Differential Pressure Gauges/Controller
- Measure and control both positive and negative low air
or gas pressures
- Provide an ideal way of monitoring and controlling the
positive pressure differential required for cleanrooms
- Enable you to meet FED STD 209E regarding cleanroom pressure
- Ideal for measuring differential pressure in gloveboxes and air flow in exhaust hoods
- MAGNEHELIC® Principle ensures wear-free accuracy within
2% of full scale
- Resists shock and vibration
- Available in a number of pressure gauges to suit a wide
range of applications, such as gauging air filters, monitoring
air conditioning systems, and measuring static air pressure
and air vehicles
If your facility incorporates a laminar flow cleanroom, these
MAGNEHELIC® and PHOTOHELIC® differential pressure
gauges can help you maintain the positive pressure necessary
to block inrushing contaminants that can damage sensitive
materials and operations. In doing so, they also help to meet
the requirements and recommendations set forth in FED STD
209E which specifies that a minimum positive pressure of 0.05"
of water differential be maintained between the cleanroom
and adjacent areas.
Chatterless, Wear-Free Accuracy
These gauges incorporate an exclusive MAGNEHELIC® Principle
that eliminates wear, backlash, and hysteresis. The result
is a remarkably high standard of accurate, dependable gauge
performance at a modest price.
This MAGNEHELIC® Principle is a method of transmitting
the effects of changes in air pressure from a diaphragm to
an indicating pointerby means of magnetic linkage and
without the use of gears or other direct mechanical linkages.
This system avoids wear and physical contact, which might
destroy the accuracy and sensitivity of the instrument. It
delivers accuracy to within 2% of full scale.
This principle offers numerous advantages over other gauges.
Because it uses no fluid, it eliminates evaporation, freezing,
or toxicity problems. It also ensures inertia-free, drift-free
pointer movement and offers unusually high resistance to shock
and vibration. These gauges are also unharmed by pressure
surges up to 15 psig and by ambient temperature fluctuations
between 20 and 140 degrees F.
Both MAGNEHELIC® and PHOTOHELIC® gauges feature easy-to-read
4" dials that quickly provide gas pressurespositive,
negative or differential. Because operation does not depend
on gravity, you can either face- or flush-mount them in any
position. Gauges can also be mounted on panels either inside
or outside of the cleanroom; if mounted inside, the low pressure
ports of the room pressure gauges can be connected together,
and a single tube routed to outside the room.
Versatile Applications
Use the MAGNEHELIC® gauges (range of .25-4.0" WC)
to determine positive pressure differentials between the cleanroom
and adjacent areas. MAGNEHELIC® gauges can also be used
to measure pressure drops across pre-filters and absolute
filters.
A PHOTOHELIC® gauge/switch can also be used to control
makeup or exhaust air dampers in order to maintain the room
pressure within prescribed limits. All gauges can be mounted
on a control panel. Gauge calibration is accomplished between
room readings. In this application the PHOTOHELIC® gauge
serves as the master gauge.
These units can also be used to check air filters, to sense
static pressure or to measure air velocity and volume.
|
|
|
The MAGNEHELIC® Pressure Gauge
The Magnehelic® is the industry standard to measure fan and blowerpressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid am-plifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.
| MAGNEHELIC® Gauges |
Pressure Range
(inches WC) |
Weight |
Uninstalled |
Installed |
| Cat. # |
$/Each |
Cat. # |
$/Each |
| 0-0.5 |
1 lb. 2 ozs. |
2625-08 |
Login |
2625-30 |
Login |
| 0-1.0 |
1 lb. 2 ozs. |
2625-09 |
Login |
2625-31 |
Login |
| 0-2.0 |
1 lb. 2 ozs. |
2625-10 |
Login |
2625-32 |
Login |
| 0-3.0 |
1 lb. 2 ozs. |
2625-11 |
Login |
2625-33 |
Login |
| 0-4.0 |
1 lb. 2 ozs. |
2625-12 |
Login |
2625-34 |
Login |
| .25-0-.25 |
1 lb. 2 ozs. |
— |
— |
6600-86 |
Login |
|
|
|
PHOTOHELIC® Pressure Control
PHOTOHELIC® models combine the MAGNEHELIC® gauge with
a precise pressure switch that lets you control low and high
gas pressures. Knob controls adjust dual set points, which
allow for variable deadband control. These set points contain
photocells that actuate DPDT relays when room pressures reach
a preset upper or lower limit, and they can be set up to control
corrective damper action. As the room pressure changes in
response to damper motion, and the indicator returns to the
null band, damper motion is halted.
| PHOTOHELIC® Gauges |
Pressure Range (inches WC) |
Weight |
Uninstalled |
Installed |
| Cat. # |
$/Each |
Cat. # |
$/Each |
| 0-0.5 |
4 lbs. |
2625-13 |
Login |
2625-35 |
Login |
| 0-1.0 |
4 lbs. |
2625-14 |
Login |
2625-36 |
Login |
| 0-2.0 |
4 lbs. |
2625-15 |
Login |
2625-37 |
Login |
| 0-3.0 |
4 lbs. |
2625-16 |
Login |
2625-38 |
Login |
| 0-4.0 |
4 lbs. |
2625-17 |
Login |
2625-39 |
Login |
| .25-0-.25 |
4 lbs. |
— |
— |
6600-87 |
Login
|
|
|
|
Minihelic II® Differential Pressure Gauges
Combining clean design, small size and low cost with enough accuracy for all but the most demanding applications our Minihelic®II gauge offers the latest in design features for a dial type differential pressure gauge. It is our most compact gauge but is easy to read and can safely operate at total pressures up to 30 psig. The Minihelic®II is designed for panel mounting in a single 25⁄8" diameter hole. Standard pressure connections are barbed fittings for .1875" I.D. tubing; optional .125" male NPT connections are also available. Over-pressure protection is built into the Minihelic II® gauge by means of a blow-out membrane molded in conjunction with the diaphragm. Accidental over-ranging up to the rated total pressure will not damage the gauge.
With removable lens and rear housing, the gauge may be easily serviced at minimum cost. With the housing molded from mineral and glass-filled nylon and the lens molded from polycarbonate, the gauge will with stand rough use and exposure as well as high total pressure. The 5% accuracy and low cost of the Minihelic®II gauge make it well suited for a wide variety of OEM and user applications.
| MINIHELIC II® Gauges |
Pressure Range
(inches WC) |
Weight |
Uninstalled |
Installed |
| Cat. # |
$/Each |
Cat. # |
$/Each |
| 0-0.5 |
6 ozs. |
2625-43 |
Login |
2625-48 |
Login |
| 0-1.0 |
6 ozs. |
2625-44 |
Login |
2625-49 |
Login |
| 0-2.0 |
6 ozs. |
2625-45 |
Login |
2625-50 |
Login |
| 0-3.0 |
6 ozs. |
2625-46 |
Login |
2625-51 |
Login |
| 0-5.0 |
6 ozs. |
2625-47 |
Login |
2625-52 |
Login |
|
|
|
DIGIHELIC® Differential Pressure Gauge
The Digihelic® differential pressure controller is a 3-in-1 instrument possessing a digital display gauge, control relay switches, and a transmitter with current output. Combining these three features is a cost efficient way to save on the number of instruments needed to measure pressure, velocity and flow. The Digihelic® can achieve a 0.5% full scale accuracy, making it the perfect controller for glove boxes, hoods and clean rooms.
The Digihelic® allows the selection of pressure, velocity or volumetric flow operation in several commonly used engineering units. 2 SPDT control relays with adjustable dead bands are provided along with a scalable 4-20 mA process output.
The Digihelic® allows you to require a security code prior to any changes to the user-set programming. An easy to use, menu driven keypad also lets you set all of the following: pressure, velocity or flow operation; K-factor for use with flow sensors; rectangular or circular duct for inputting area in flow applications; set point control or set point and alarm operation; high/low alarm; automatic or manual alarm reset; alarm delay; view peak and valley process readings; digital dampening for smoothing erratic process applications; Modbus® communications; and field calibration.
| DIGIHELIC® Differential Pressure Gauge |
| |
|
Uninstalled |
Installed |
Pressure Range (inches WC) |
Weight |
Cat. # |
$/Each** |
Cat. # |
$/Each** |
| 0 – 1.0 |
14 lbs. |
2625-26 |
Login
|
2625-40 |
Login |
| 0 – 5.0 |
14 lbs. |
2625-27 |
Login
|
2625-41 |
Login |
| 1.0 – 0 – 1.0* |
14 lbs. |
2625-28 |
Login
|
2625-42 |
Login |
*Bi-Direction Range. Velocity and volumetric flow not available on bi-directional unit.
**Price includes installation |
| |