6704-27
Terra Part # 6704-27
$6,182
Usually ships in 25-31 business days

Want it faster ? Read about FasTrak

Terra Part # 6704-27
30304
$6,182
Usually ships in 25-31 business days

Want it faster ? Read about FasTrak

Product Details
  • Available Certified ISO Grade Designs: ISO 7, ISO 8
  • Power: 230/208VAC, 60Hz, 1 phase, 8 KW, 1.0 amps (blower)
  • Capacity: 1.5 tons ( 1361 kg )
  • Color: Buckeye gray
  • Cooling Net BTUH: 18,000
  • Barometric fresh air damper included
  • Includes powder-coated steel air distribution plenum mounted to the external cleanroom wall, which provides conditioned air to up to six FFUs (order FFUs and FFU Connect Packs # 6601-01 separately)
  • For effective heat dissipation this module typically requires 10’ (3048 mm) wall clearance, particularly if surrounding ceiling is <9’H (2743 mm).  If this condition is not met, customer assumes sole responsibility to provide necessary ducting or deflection of heated discharge air.
  • AC control only
  • External air baffles allow quick, easy control over percentage of recirculated/make-up air
  • Price includes modification of air distribution plenum to match associated Terra cleanroom – specify desired plenum height if ordered without Terra cleanroom.

• A/C Type: 18,000 BTU, A/C only

• Type: A/C Module

• Unit of Measure: EA

• Electrical Specifications: 240 V, 1 A, 1 Ph, 60 Hz

• Weight, Shipping: 330 lb

Features and Benefits

Learn More: Air Conditioning Alternatives

Terra recommends the following options for air conditioning in hardwall cleanrooms

Existing HVAC System

The ideal option would be to use an existing heating, ventilating and air conditioning (HVAC) system because it provides the most effective and economical means to cool your modular cleanroom. The fan/filter units (FFUs) can draw air from the surrounding room, passing conditioned air directly into the cleanroom without the need for ducting or special exhaust systems. The existing ducting can also be connected directly to each FFU using a connection kit.

Consult with an HVAC contractor to determine if the existing system has the necessary spare capacity to adequately cool the cleanroom. The additional load on an existing HVAC system can be calculated by adding together the heat dissipated by the specified number of FFUs (@ approximately 1,000 BTU/hour/unit) and the heat generated by equipment and personnel inside the cleanroom.

Split A/C System

If the existing HVAC system cannot be used, the addition of a split HVAC system would be the next best option. A split system moves the heat-generating compressor outside of the facility, eliminating noise and heat build-up in the area outside of the cleanroom.

For these applications, Terra will work with a local HVAC contractor to provide a split-type system that meets your cooling requirements and local codes. Terra will provide the ducting and recirculation system that routes exhaust air to the compressor and delivers cool air to the ceiling FFUs in ample volume to maintain the desired air velocity inside the enclosure.

Environmental Stability System

For applications requiring strict temperature and humidity control (where the above options are not suitable), Terra can provide custom HVAC modules that operate similarly to an environmental test chamber, adjusting the supply air's temperature and humidity to maintain specific conditions within tight tolerances. This type of system is particularly useful when the environment immediately outside of the cleanroom experiences significant fluctuations in temperature or relative humidity.

Typical Applications: Pharmaceutical or Medical Device Manufacturing, GMP Facilities, Testing Laboratories, High Humidity Environments

For best performance, these modules should be paired with an insulated hardwall cleanroom.

Standard Cleanroom A/C Module

The modules below provide economical cooling in facilities without adequate HVAC. Based on the cleanroom size, desired temperature, and heat dissipated inside the cleanroom, Terra will configure the appropriate number of units.

In these applications, heat removed from the cleanroom is vented into the room outside. In the case of large cleanrooms and/or significant heat-generating equipment, this vented heat will raise the ambient temperature and place greater load on the A/C modules as well as any existing HVAC system. For best performance, heat generated by the module should be exhausted outside of the facility.

Products Compliant With Your ISO Rating

High-capacity, durable, ISO-compliant system rated for thousands of operating hours.

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.

Anouncement for US
This is testing on Live - Terra Bottom