5102-62
Terra Part # 5102-62
Request Quote
Usually ships in 10-16 business days

Want it faster ? Read about FasTrak

Accessories related to Terra Part # 5102-62
62865
SPECTRUM TWO SYSTEM, 120/240 V, 50/60 Hz - Standard DTC, KBr, Sp10
Product Details
  • Detector: Standard
  • Window: KBr
  • A™ ospheric Vapor Compensation: Yes
  • Absolute Virtual Instrument: No
  • Included Software: Spectrum 10™
  • Signal - to - Noise Ratio: 9,300:1
  • Spectral Range: 8300 – 350cm-1
  • Resolution: 0.5cm-1
  • For infrared analysis of sample identity, composition, quality, and consistency
  • Features: KBc Window, A™  ospheric vapor compensation, spectral range of 8300 - 350cm-1, software and software detector
  • Intuitive Spectrum 10™ software suite
  • Dynascan fixed-mirror interferometer eliminates dynamic alignment for error compensation found in linear mirror movement systems
  • OpticsGuard™  technology protects the instrument from humidity allowing for operation in more demanding environments and increasing the time between maintenance cycles
  • Patented A™  ospheric Vapor Compensation™   (AVC) accounts for changes in CO2 and H2O in real-time to ensure instrument reliability across multiple measurements
  • Optional portability packs allow instrument to be operated without connection
  • To a main power supply
  • Optional Absolute Virtual Instrument™  (AVI) allows standardization of instruments via a gas spectra reference for increased inter-equipment and inter-site reliability
  • Accessories sold separately: Universal ATR Sampling, HATR Sampling, Portability Options, Training Software, Documentation, Services and Warranties
  • Application Packages available

Spectrometer Type: FTIR

Peltier Detector: Standard

Brand: Spectrum Two

21 CFR Part 11: No

Manufacturer SKU: L160000A

Unit of Measure: EA

Electrical Specifications: 120/240 V, 50/60 Hz

Weight, Product: 25 Lbs

Dimensions, Product: 15"W x 17"D x 21"H

Weight, Shipping: 45 lb

Dimensions, Shipping: 18"W x 20"D x 24"H

Package Type: Box

Buy Accessories
  1. Ideal for analysis of solids and liquids  |  5102-66 displayed
    Request Quote
    Increase Down Increase Up
  2.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  3.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  4.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  5. BATTERY PACK portable/UPS
    Request Quote
    Increase Down Increase Up
  6. SPECTRUM TWO CARRY CASE
    Request Quote
    Increase Down Increase Up
  7.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  8.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  9.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  10.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  11. FTIR training kit  |  5102-76 displayed
    Request Quote
    Increase Down Increase Up
  12. FTIR training kit  |  5102-76 displayed
    Request Quote
    Increase Down Increase Up
  13.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  14.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  15.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  16.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  17.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  18.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  19.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  20.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  21.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  22.  |  5102-04 displayed
    Request Quote
    Increase Down Increase Up
  23. Spectrum Two Power Cord
    Request Quote
    Increase Down Increase Up
  24. Spectrum RX1 Liquid and Mull Complete Sampling Kit
    Request Quote
    Increase Down Increase Up
  25. FTIR Educational Resource Pack for the Spectrum Two and Frontier
    Request Quote
    Increase Down Increase Up
  26. FTIR Pharmacopeia Compliance Resource Pack for Spectrum Two & Frontier
    Request Quote
    Increase Down Increase Up
  27. FTIR Nutraceutical Compliance Resource Pack
    Request Quote
    Increase Down Increase Up
  28. FTIR Polymer Resource Pack for Spectrum Two and Frontier
    Request Quote
    Increase Down Increase Up
  29. EH ASTM D7066 Analysis Pack for Spectrum Two and Frontier
    Request Quote
    Increase Down Increase Up
  30. Environmental Hydrocarbon FTIR Cyclohex for Spectrum Two and Frontier
    Request Quote
    Increase Down Increase Up
  31. ENVIROMENTAL HYDROCARBON ATR APPLICATION PACK (incl. PE HATR) for Spectrum Two and Frontier
    Request Quote
    Increase Down Increase Up
  32. IN-SERVICE LUBRICANTS APPLICATION PACK for Spectrum Two & Frontier
    Request Quote
    Increase Down Increase Up
  33. IR BIODIESEL APPLICATION PACK for Spectrum Two and Frontier
    Request Quote
    Increase Down Increase Up
  34. IR BENZENE IN GASOLINE ASTM D4053 - 04 APPLICATION PACK for Spectrum Two and Frontier
    Request Quote
    Increase Down Increase Up
  35. Product Training/In-Service
    Request Quote
    Increase Down Increase Up
  36. Planned Maintenance Service
    Request Quote
    Increase Down Increase Up
  37. Extended Product Warranty
    Request Quote
    Increase Down Increase Up

Features and Benefits

Learn More: Spectrum Two Spectrometers

More Information

Patented Features for Consistent Performance of Spectrum Two FTIR Spectrometers

Dynascan fixed mirror-pair interferometer for error compensation eliminates the need for dynamic alignment OpticsGuard technology protects the instrument from humidity during operation in more demanding environments and increasing the time between maintenance cycles; long-life desiccant for maximum instrument uptime.

Atmospheric Vapor Compensation™ (AVC) compensate CO2 and H2 in real-time to ensure instrument reliability across multiple measurements.

Optional Absolute Virtual Instrument (AVI) uses gas phase spectra for accurate calibration, standardizes (to a higher degree of accuracy) wavenumber and line shape for precise transfer between instruments side-by-side or remote locations.

Additional Options:

Temperature-stabilized, high-performance DTGS (deuterated triglycine sulfate) MIR detector with a SNR of 14,500:1. Ideal for low-light, high throughput applications

Absolute Virtual Instrument™ (AVI) allows standardization of instruments via a gas spectra reference for increased inter-equipment and inter-site reliability

Automatic Performance Verification features an integrated, fully automatic filter wheel with traceable reference materials and ZnSe windows, for data collection over a spectral range of 6,000-550 cm-1 highly humid environments.

Applications

Fourier-Transformation Infrared (FTIR) Spectroscopy is used in a host of applications from quality control to polymer research. FTIR scans a solid, liquid, or gas to determine a unique molecular fingerprint. Application pack add-ons are available; inquire for pricing and product details.

  • Pharmacy and Nutraceuticals
  • Academia
  • Polymer identification and quantification of additives
  • In-service lubricants and fuels for construction and mining
Pharmacy and Nutraceuticals
Academia
Polymer identification and quantification of additives
In-service lubricants and fuels for construction and mining

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.