Select Product
Voltage

Configuration

Water Production Rate

Total Organic Carbon

Endotoxin Removal

Model

System Features

Manufacturer SKU

Terra Part # Price Ships in
120/240 V Benchtop 31.7 Gal/hr 1-5 ppb <0.001 EU/mL GenPure xCAD Plus UV 50136152 1714-48A 73400 $10,242 5-7 Days 2
Ships Free In stock
120/240 V Benchtop 31.7 Gal/hr 1-5 ppb <0.001 EU/mL GenPure xCAD Plus UV/UF 50136151 1714-50 56374 $10,755 10-20 Days 3
Ships Free
120/240 V Benchtop 31.7 Gal/hr 1-5 ppb <0.001 EU/mL GenPure xCAD Plus UV/UF-TOC 50136146 1714-53 56377 $11,267 10-20 Days 4
Ships Free
120/240 V Wall Mount 31.7 Gal/hr 1-5 ppb <0.001 EU/mL GenPure xCAD Plus UV/UF 50136169 1714-55A 73403 $10,755 5-7 Days 5
Ships Free In stock
120/240 V Wall Mount 31.7 Gal/hr 1-5 ppb <0.001 EU/mL GenPure xCAD Plus UV/UF-TOC 50136172 1714-59 56389 $11,267 10-20 Days 6
Ships Free
120/240 V Benchtop 31.7 Gal/hr 1-5 ppb GenPure xCAD Plus UV-TOC 50136153 1714-52 56376 $10,755 10-20 Days 7
Ships Free
120/240 V Wall Mount 31.7 Gal/hr 1-5 ppb GenPure xCAD Plus UV 50136170 1714-57 56387 $10,169 10-20 Days 8
Ships Free
120/240 V Wall Mount 31.7 Gal/hr 1-5 ppb GenPure xCAD Plus UV-TOC 50136171 1714-58 56388 $10,755 10-20 Days 9
Ships Free
Voltage
Configuration
Water Production Rate
Total Organic Carbon
Endotoxin Removal
Model
System Features
Manufacturer SKU
Item ordered before. Click on bagde to see the order.

Up to 30-day trial periods, free return shipping and on-site training available for qualified equipment.

Request demo from your product specialist or add note to your order or quote request.

Some ship in:
Usually Ships in:
Free shipping in contiguous USA
Custom-configured product. Contact Terra by phone, chat or email for a project-specific quote.
Custom-configured product. Contact Terra by phone, chat or email for a project-specific quote.
Select a product line for product summary
Product Details
Product Details
  • Barnstead GenPure xCAD Plus Ultrapure Water Purification Systems in benchtop and wall mount models simultaneously dispenses up to 3 remote dispensers
  • Water purifier delivers up to 200 liters a day of ultrapure Type 1 water
  • Available in Ultrafiltration (UF), Ultraviolet (UV) Intensity Monitoring and Total Organic Compound Monitoring (TOC) systems
  • GLP-Compliant model exceed ASTM Type I, ISO 3696 Grade 1, ASTM D1193 and CLSI-CLRW international standards
  • Includes Extended Control and Dispenser (xCAD) with an action radius of 32 inches delivers precise volume dosing at the press of a button for fully automatic volume control
  • Features: simultaneous dispensing, integrated feed water monitoring, leak detection, automatic volume control and feed water monitoring
  • Flow rate, max.: Up to 2L/min.
  • Operating pressure min. /max. : 29-87 psi (2 to 6 bar)
  • Conductivity: 0.055µS/cm
  • Resistance at 25°C: 18.2MW?cm
  • Bacterial content (CFU/mL) : <1
  • Particles >0.2µM/mL: <1
  • Feed Water Connector: 3/4 in. radius of hose connector
  • Temperature min./max. : 2° - 35°C
Features & Benefits

Features & Benefits

Learn More: GenPure xCAD

Additional Features of Barnstead GenPure xCAD Plus

  • Ultraviolet (UV) Oxidation effectively prevents bacterial contamination and oxidizes organics to produce pure water with low TOC levels; prevents risk of false TOC value as a result of diminished UV intensity; combination of 185/254 nm oxidizes organic compounds and allows for total oxidizable carbon levels of less than 5 ppb ideal for applications requiring extremely low levels of organics
  • Ultrafiltration (UF) removes molecules (pyrogens, nucleases, microorganisms and particulates) above their rated size; ideal for tissue culture, cell culture and media separation
  • Combination of Ultraviolet Oxidation and Ultrafiltration (UV/UF) produces water virtually free of all impurities; removes nucleases such as RNase and DNase and pyrogens; produces water with low TOC and pyrogen levels
  • Online Total Organic Carbon (TOC) with UV Intensity monitors real-time continual measurement of organic substances present in the water; continuously monitors UV intensity and removes risk of false TOC values caused by diminished UV intensity; alerts user when UV lamp is insufficient for accurate TOC measurements
  • All models exceed international standards ASTM Type I, ISO 3696 Grade 1, ASTM D1193 and CLSI-CLRW
  • Bench and wall mount models include mounting bracket up to 8 ft. (2.5 m) from main unit; bench models can be mounted under bench
  • Electronic dosing with automatic volume control of 0.01-65 L with <2% accuracy
  • Integrated feed water monitoring measures water conductivity with measuring cell and immediately displays fault message if quality of feed water drops below set value
  • Conductivity cells carefully calibrated before each measurement with built-in reference resistance with cell constants at 0.01 cm-; platinum chip sensor measures temperature with ± 0.1°C accuracy
  • Aquastop quick connect allows cartridge replacement within seconds between uses and in mid-operation; one part number ordering
  • Suitable for applications requiring Type 1 ultrapure water: life sciences and analytical chemistry
  • Ergonomic design with tilting display and swivel arm
  • Models are ready to use
GLP-compliant documentation
  • Operating system protected by real-time clock and code prevents unauthorized changes to system settings
  • Safe data transfer of all measured data, faults, date and time to a PC computer or log printer with RS-232 interface with adjustable send
  • Digital microprocessor control automatically monitors and stores faults from last four weeks
  • On and off switch for USP-compliant conductivity measurement with temperature compensation
Feed Water Requirements
  • Source: Portable tap water, pretreated by reverse osmosis, ion exchange or distillation
  • Feed water conductivity, uS/cm: <2
  • TOC, ppb: Max 50
  • Bacteria count, CFU/ml: <100
  • Turbidity, NTU: <1.0
  • Temperature, C: 2-35
  • Pressure, psi (bar): 1.4-87 (0.1-6)
Specifications and Additional Features for Barnstead GenPure xCAD Plus
  • Benchtop xCAD Dimensions W x D x H in. (mm): 10.2 x 21 x 28.5 (260 x 530 x 725)
  • Wall Mount xCAD Dimensions W x D x H in. (mm): 10.2 x 21 x 25.8 (260 x 530 x 655)
  • Electrical Requirements: 90-240V, 50/60 Hz
  • Power Consumption: 0.1kW
  • Flow rate: Up to 2L/min.
  • Operating pressure, min. /max. 29-87 psi (2 to 6 bar)
  • Conductivity 0.055µS/cm
  • Resistance at 25°C 18.2MWΩcm
  • Bacterial content (CFU/mL) <1
  • Particles <0.2µM/mL <1
  • Feed Water Connector 3/4 in. radius of hose connector
  • Temperature min. /max. 2° - 35°C
Model GenPure xCAD Plus GenPure xCAD Plus
UV system
GenPure xCAD Plus
UF system
GenPure xCAD Plus
UV/UF system
GenPure xCAD Plus
UV - TOC system
GenPure xCAD Plus
UV/UF - TOC system
Applications AA, IC, ICP,
standard buffer
Inorganic and organic trace analysis, HPLC, ICP-MS, IC, TOC analysis Molecular biology,
microbiology, PCR, IVF, monoclonal
antibodies
Molecular biology, PCR, DNA, monoclonal antibodies,
cell culture media
Chemical analysis (trace analysis, HPLC, IC, ICP-MS, TOC measurements) Biosciences
(cell and tissue culture
media, PCR, DNA,
monoclonal antibodies)
Resistance at 25°C: MΩ.cm 18.2 for all models
Conductivity, µS/cm 0.055 for all models
TOC, ppb 5-10 1-5 5-10 1-5 1-5 1-5
Bacteria, CFU/mL <1 for all models
Particles, 0.22 µm/mL <1 for all models
Endotoxins, EU/mL n/a n/a <0.001 <0.001 n/a <0.001
TOC Monitor n/a n/a n/a n/a Standard Standard
Products similar to this one
Other products you may find relevant
Buy Accessories

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.