Browse our wide selection of aseptic containment isolators by GERMFREE and Labconco. Call, email, or chat with a live product specialist to request a free quote and discuss custom solutions with an expert.
Labconco's pure2 Aseptic Isolator is designed for a wide variety of critical processes. It maintains unidirectional GMP Grade A, ISO 5 conditions with selectable positive or negative pressure operation, plus fully integrated fast and safe H2O2 decontamination cycles.
Germfree Radiopharmaceutical Isolation Enclosures support unique drug products under USP Chapter <825> including radionuclide emitters, commercially-manufactured radiopharmaceutical kit preparation, FDA-approved multi-dose vial dilution, and the labeling of human blood products with radionuclides.
LGFI Radiopharmaceutical Isolators include negative pressure, lead shielding, and 100% enclosed containment operation for USP 825 compounding and CETA CAG-002-2006 Performance Standard validation.
GMP and FDA 21 CFR Part II compliant Pure2 Aseptic Isolator designed with a sealed containment system for safe and efficient processing in ISO Class 5 conditions with unidirectional airflow
Modular and customizable design available in two-glove (LSKPURE2GLV) or four-glove (LSKPURE4GLV) configurations
Built-in SKAN nanox catalytic converter requires no connection to external exhaust system
Features: patented skanfog technology, advanced HEPA filtration, unidirectional airflow, H2O2 decontamination, and ergonomic access, includes airflow monitor
Note: when ordering specify glove configurations, airlock (1 or 2), operating pressure (-60 or +60), and customization options
Available Certified ISO Grade Designs: ISO 5, ISO 6, ISO 7, ISO 8
Class III biological containment for highly pathogenic samples Allows for quick, economical expansion of lab capabilities or for emergency preparedness
Designed for operator comfort and easy cleaning/decontamination
Stainless steel, oval-shaped glove ports for wider range of motion; gloves can be exchanged without breaching containment
Includes one set of Hypalon® gloves (Size 9.75 ambidextrous, 815mm-long)
HEPA-filtered supply air and double-HEPA-filtered exhaust air, designed for connection to external exhaust system Exhaust system requirements: 50 CFM @ 2"WC (8.5 m^3/hr. @ 500 Pa)
Available Certified ISO Grade Designs: ISO 5, ISO 6, ISO 7, ISO 8
Meets USP 797 standards by providing an ISO 5 environment for compounding
Work area and antechamber are HEPA-filtered, laminar airflow for positive pressure (non-hazardous) differential Functions as a Compounding Aseptic Isolator (CAI)
Benchtop, 44 model available without the integrated stand (#5607-45)
HEPA filter removes organisms and particulates 0.3 microns in size with 99.99% efficiency
Digital pressure gauge will issue audible alert if pressure drops below safe levels
Available Certified ISO Grade Designs: ISO 5, ISO 6, ISO 7, ISO 8
Germfree LFGI provides both operator and product protection when compounding
Validated to CETA CAG-002-2006 and maintains ISO 5 particle counts inside the work chamber under dynamic operating conditions
Both supply and exhaust air passes through HEPA filters to capture contaminants for full containment (99.99% efficient at 0.3 microns)
Exhaust port can be connected to external exhaust system for ducting to the outside (requires exhaust transition) Sealed, HEPA-purged airlock features a timed cycle and slide-out tray to put transferred materials within easy reach of the glove port
4 waste removal tube and 2.5 sharps disposal tube with stoppers for sealing off the chamber
Aseptic, low bio-burden, withstands high temperature and humidity fluctuation; low carbon rating indicates reduced percentage for enhanced corrosion resistance
Terra's mission is to help customers in highly regulated industries transform the world with critical environment solutions that improve health, safety, performance, and yields. These environments may comply with stringent UL, ISO, IEST, ASTM and OSHA standards and local requirements.
Germfree’s Radiopharmacy Compounding Aseptic Containment Isolators (CACIs) feature lead shielding for compounding of sterile radiopharmaceuticals; they include hydraulic height adjustment, interior outlets and waste tubes.
Negative Pressure Protects Product and Operator
Negative pressure operation of the Germfree LFGI Glove Box contains biohazards to meet USP-800 requirements for compounding hazardous materials
Positive Pressure Protects the Product
Positive pressure operation of the Germfree LFGI Glove Box creates an ISO 5 environment to meet USP-797 requirements for sterile compounding
Germfree Class III Biological Safety Cabinet shown with optional active airlock, VHP ports, UPS battery backup, exhaust blower and casters | 5607-25 displayedGermfree Stainless Steel SEA Class III BSC Glove Box with Two Glove PortsGermFree's stainless steel SEA III BSC provides safe and secure biohazard containment while protecting samples from ambient moisture and contaminants; two-port model shown with optional active airlock VHP ports, UPS battery backup, exhaust blower and casters.
Germfree’s Radiopharmacy Compounding Aseptic Containment Isolators feature lead-shielding around the ISO 5 workspace | 5607-22 displayedGermfree Radiopharmacy Compounding Aseptic Containment Isolators (CACIs)Germfree’s Radiopharmacy Compounding Aseptic Containment Isolator (CACI) features lead shielding around the ISO 5 workspace to allow compounding of sterile radiopharmaceuticals (dose calibrator not included).
SEA-III Class III Biological Safety Cabinet 3 Port Glovebox | 5607-26 displayedGermFree Class III Biological Safety Cabinet Glovebox3-port model shown. Provides safe and secure containment of hazardous biological materials. Protects user, product and environment from biological hazards
This video describes the IQ/OQ process for Equipment and CleanroomsTerra Universal IQ-OQ ProcessThis video describes the IQ/OQ process for Equipment and Cleanrooms