FREE CONSULTATION714-578-6100
  1. Home
  2. promotions
  3. sweets
  4. biosafe-pass-through-sweets.php

Pass-Through Chambers for Cleanrooms

Vertical Laminar Flow Station
Acrylic
(Model No. 1993-12C)
 
Polypropylene
(Model No. 1993-06)
 
Features Key
  Standard
  Option

A Five standard, application-specific materials to choose among
B Floor-mount models include cart ramps
C Durable, reliable interlock prevents cross contamination
D Lifting latches eliminate hinge strain for long service life
E Options include HEPA air showers, CleanTops, UV sterilization, foot-operated doors

Compare!
304 Stainless Steel door frames are standard on all Terra Pass-Throughs
Wafer_CE

304 Stainless Steel
(Model No. 6705-26)
  304 stainless steel pass-through

Cleanroom Pass-Through Benefits

  • Contamination-free transfer of materials in and out of the cleanroom
  • Eliminates unnecessary personnel entry
  • Full range of sizes meets any application
  • Stainless steel doors extend service life of plastic and laminate chamber—a must in a production environment!
  • Foolproof interlock mechanism prevents cross-contamination, is reliable and maintenance-free
  • Material options accommodate many application requirements, from chemical resistance to static control to fire safety
  • Accessories include LockLatch™, safety sprinkler, air shower, and Class 10 HEPA filter/blower module
  • Easy to install

Firmlok Interlock

FirmLok™ Interlock: Clean,
reliable operation

304 or 316 stainless steel


Shutting the Door on Contamination

These Pass-Through Chambers cut down significantly on traffic and contamination by providing a better, safer way to transfer equipment and paperwork.

304 Stainless steel or powder-coated steel pass-throughs ensure clean operation. For especially stringent particle requirements, select an UltraClean™ electropolished 304 stainless steel pass-through.

Polypropylene and PVC models are suitable for chemical pass-through applications, and Static-Dissipative PVC models combine excellent chemical resistance with a surface resistivity of about 107 ohms/square for enhanced static and particle control. Each model features viewing windows of a compatible material.

Doors on either side can be outfitted with a mechanical interlock that keeps personnel from passing particles through the chamber. This device allows only one door at a time to open, and thus the amount of air that can enter the cleanroom is restricted to a very small volume. The no-maintenance interlock has no power, gas, or other facility requirement, so it continues to operate when other systems shut down.


ULPA Filtered Air Shower Clears the Air!

Terra offers an ULPA filtered air shower for enhanced particle control.

This option incorporates a brushless motor and 125 CFM (212.5 m³/hr) variable-speed impeller to draw air from the "clean" side of the pass-through into an ULPA filter (rated 99.999% efficient with 0.12µm-diameter particles).

A magnetic sensor switch, installed on the "dirty" side door, activates the unit after the door has been opened and then closed. The shower washes the chamber with ULPA-filtered air to remove any contaminants that might have entered the chamber (the operation period is adjustable from 15 to 180 seconds). During operation, a red status light in the "cleanroom" side of the shower glows to warn operators not to open a door. When the shower shuts off, a green status light indicates that the door may be opened.

Exhaust air flows out of vents on the "dirty" side of the pass-through chamber (a microporous filter eliminates the chance of contamination in the event of a negative pressure). The cleanroom intake ensures a long filter life, and filter change-outs can be performed in a matter of seconds.


Pass-Through Installation

Cleanroom Pass-Through Installation

Cleanroom Pass-Through Chambers can be installed in a number of ways, depending on the wall or door that will support them. The ordering chart indicates the cut-out size necessary to support each model size (simply add .5" [13 mm] to the chamber width and height). Terra offers mounting brackets and hardware to ensure secure mounting. In most cases, a bracket kit provides ample support. Models are available for either wall mounting (at a convenient standing height) or floor mounting (to allow passage of carts and other equipment along the floor). Select support brackets for 36"D (914 mm) wall-mount models. Note: Brackets are mounted to allow chambers to protrude 2" (51 mm) on the cleanroom side (specify other desired position).
Support Brackets
Two recommended for cabinets 36"D (914 mm)
Cat. # Price
Stainless Steel 1993-60B Call TUI
Powder-Coated Steel 1993-83B Call TUI

Cleanroom Pass-Through Ordering Guide

Consider the following options in making your selection:

Wall or Floor Mount? Wall-mount models can be positioned at a comfortable standing height; floor-mount models include a low-profile ramp to allow carts to be wheeled into the chamber. Special mounting hardware is included for each model. Order support brackets for larger wall-mount models (see illustration above). Your wall cutout should be .5" (13 mm) larger than the overall height and width of your chamber.

Pass-Through Chamber Material? Select among seven standard materials. Others (including polycarbonate and dissipative polycarbonate) are also available.

Sliding Doors? These easy-open doors eliminate clearance requirements.

Interlocks? Interlocks are recommended to prevent cross contamination.

Reinforced Doors—Plastic cabinets come with stainless steel reinforced door frames on a standard basis.

Other Pass-Through Options include a filter/blower module, shelves (with electropolished stainless steel racks), illuminator, and grounding terminals.


Standard Pass-Through Mounting

All models include mounting brackets (stainless or powder-coated steel). All brackets require .25" (6 mm) clearance between the wall cut-out and the pass-through. Standard mounting is 2" (51 mm) from the front of the cleanroom side (specify other desired location). For electropolishing, add "-2" to the part number and $75 to the price.

Custom Sizes and Designs are No Problem!

Don't see the right size or design? Let us know your requirements—we'll customize a system to your specs!

Pass-Through Ordering Information

The chart below provides detailed information on standard Pass-through Chambers.
 
Before you order,
  Consider Your Options!
    QuickQuote Planner
    Pre-Engineered Custom Designs
    Specialty Plastics
 
 
Architects & Builders: Click resource icons
SPEC logo BIM logo
Pass-Through Chambers (Doors are made of material indicated in parenthesis: other designs available.)
Type (1)

Outside
Dimensions
W" x D" x H"
(mm)
Add 0.5" (13 mm) to WxH
for cutout
Electropolished
304 Stainless Steel (2)
(Stainless Steel Doors/
Dissipative PVC Windows)
Internal Access = W" x H"
minus 2" (51 mm)
304 Stainless Steel (2)
(Stainless Steel Doors/
Dissipative PVC Windows)
Internal Access = W" x H"
minus 2" (51 mm)
Powder-Coated Steel
(Powder-Coated Steel Doors/
Dissipative PVC Windows)
Internal Access = W" x H"
minus 2" (51 mm)
Cat. # Price Cat. # Price Cat. # Price
Wall Mount 12 x 12 x 12
(305 x 305 x 305)
1992-01C Call TUI
1992-09C Call TUI
1991-00C Call TUI
12 x 12 x 24
(305 x 305 x 610)
1992-02C Call TUI
1992-10C Call TUI
1992-18C Call TUI
18 x 18 x 16
(457 x 457 x 406)
1992-03C Call TUI
1992-11C Call TUI
1992-00C Call TUI
18 x 18 x 24
(457 x 457 x 610)
1992-04C Call TUI
1992-12C Call TUI
1992-19C Call TUI
24 x 24 x 16
(610 x 610 x 406)
1992-05C Call TUI
1992-13C Call TUI
1993-00C Call TUI
24 x 24 x 24
(610 x 610 x 610)
1992-06C Call TUI
1992-14C Call TUI
1992-20C Call TUI
24 x 36 x 24
(610 x 914 x 610)
1992-07C Call TUI
1992-15C Call TUI
1992-21C Call TUI
36 x 36 x 24
(914 x 914 x 610)
1992-74C Call TUI
1997-03C Call TUI
1992-22C Call TUI
24 x 24 x 36
(610 x 610 x 914)
1992-08C Call TUI
1992-16C Call TUI
1992-23C Call TUI
24 x 24 x 48
(610 x 610 x 1219)
6705-25C Call TUI
6705-26C Call TUI
6705-27C Call TUI
36 x 36 x 36
(914 x 914 x 914)
1992-99C Call TUI
1997-06C Call TUI
1992-24C Call TUI
36 x 36 x 48
(914 x 914 x 1219)
1997-01C Call TUI
1997-08C Call TUI
1992-25C Call TUI
Floor Mount(1)
with Ramp
24 x 24 x 36
(610 x 610 x 914)
1992-81C Call TUI
1992-84C Call TUI
1993-01C Call TUI
36 x 36 x 36
(914 x 914 x 914)
1992-82C Call TUI
1992-85C Call TUI
1993-02C Call TUI
36 x 36 x 48
(914 x 914 x 1219)
1992-83C Call TUI
1992-86C Call TUI
1993-03C Call TUI
(1) Floor Mount models include low-profile access ramps for easy transport of carts (subtract 1" (25 mm) from internal vertical clearance to compensate for ramps)
(2) For critical applications select Terra's BioSafe Stainless Steel Pass-Throughs.
*Acrylic is damaged by alcohol and other cleaning agents.
Pass-Through Chambers (Doors are made of material indicated in parenthesis: other designs available.)
Type (1)
Outside
Dimensions
(W" x D" x H")
(mm)
Add 1.5" (39 mm) to W" and
0.5" (13 mm) to H" for cutout
Polypropylene
(Nondissipative PVC Doors)
Internal Access =
W" x H" minus 1"(25 mm)
Static Dissipative
PVC
(Dissipative PVC Doors)
Internal Access = W" x H"
minus 2" (51 mm)
Acrylic*
(Acrylic Doors)
Internal Access = W" x H"
minus 2" (51 mm)
Cat. # Price Cat. # Price Cat. # Price
Wall Mount 12 x 12 x 12
(305 x 305 x 305)
1992-26C Call TUI
1992-37C Call TUI
1993-12C Call TUI
12 x 12 x 24
(305 x 305 x 610)
1992-27C Call TUI
1992-38C Call TUI
1948-20C Call TUI
18 x 18 x 16
(457 x 457 x 406)
1992-28C Call TUI
1992-39C Call TUI
1992-48C Call TUI
18 x 18 x 24
(457 x 457 x 610)
1992-29C Call TUI
1992-40C Call TUI
1992-49C Call TUI
24 x 24 x 16
(610 x 610 x 406)
1992-30C Call TUI
1992-41C Call TUI
1992-50C Call TUI
24 x 24 x 24
(610 x 610 x 610)
1992-31C Call TUI
1992-42C Call TUI
1992-51C Call TUI
24 x 36 x 24
(610 x 914 x 610)
1992-32C Call TUI
1992-43C Call TUI
1992-44C Call TUI
36 x 36 x 24
(914 x 914 x 610)
1992-33C Call TUI
1992-52C Call TUI
24 x 24 x 36
(610 x 610 x 914)
1992-34C Call TUI
1992-45C Call TUI
1992-46C Call TUI
24 x 24 x 48
(610 x 610 x 1219)
6705-28C Call TUI
6705-29C Call TUI
36 x 36 x 36
(914 x 914 x 914)
1992-35C Call TUI
1992-53C Call TUI
36 x 36 x 48
(914 x 914 x 1219)
1992-36C Call TUI
1992-80C Call TUI
Floor Mount(1)
with Ramp
24 x 24 x 36
(610 x 610 x 914)
1993-04C Call TUI
1993-07C Call TUI
1993-08C Call TUI
36 x 36 x 36
(914 x 914 x 914)
1993-05C Call TUI
1993-09C Call TUI
36 x 36 x 48
(914 x 914 x 1219)
1993-06C Call TUI
1993-10C Call TUI
(1) Floor Mount models include low-profile access ramps for easy transport of carts (subtract 1" (25 mm) from internal vertical clearance to compensate for ramps)
*Acrylic is damaged by alcohol and other cleaning agents.

FirmLock™ Interlock
Firmlok interlock  
FirmLock™ Interlock*
Mount Type Chamber Dimensions
W" x D" x H"
(mm)
Add .5" (13 mm) to
W" x H"
for cut-out
FirmLok™ Interlock (1)
Cat. # Price
Wall (1) 12 x 12 x 12
(305 x 305 x 305)
6705-50A $ 612
12 x 12 x 24
(305 x 305 x 610)
6705-50A $ 612
18 x 18 x 16
(457 x 457 x 406)
6705-51A $ 689
18 x 18 x 24
(457 x 457 x 610)
6705-51A $ 689
24 x 24 x 16
(610 x 610 x 406)
6705-52A $ 765
24 x 24 x 24
(610 x 610 x 610)
6705-52A $ 765
24 x 36 x 24
(610 x 914 x 610)
6705-53A $ 919
36 x 36 x 24
(914 x 914 x 610)
6705-53A $ 919
24 x 24 x 36
(610 x 610 x 914)
6705-52A $ 765
24 x 24 x 48
(610 x 610 x 457)
6705-52A $ 765
36 x 36 x 36
(914 x 914 x 914)
6705-53A $ 919
36 x 36 x 48
(914 x 914 x 1219)
6705-53A $ 919
Floor 24 x 24 x 36
(610 x 610 x 914)
6705-52A $ 765
36 x 36 x 36
(914 x 914 x 914)
6705-53A $ 919
36 x 36 x 48
(914 x 914 x 1219)
6705-53A $ 919
(1) All use a fail-proof mechanical design that requires no maintenance. Made of stainless steel. Must be specified when Pass-Through is ordered (cannot be retrofitted). For electropolishing add “-2" to the Cat. number and $75.00 to the price.
FirmLok™ Interlock:
Clean, reliable operation
Standard Intallation:
Mechanical interlock
requires that both
doors close on the
same sidewal, as shown

 
Click to leave a message. 24-hour sales and tech phone support, M - F
Go to...
Go To
Laboratory-Equipment.com