Select Product

Width

Base Stand

Sash Opening

Voltage

UV Lamp

Manufacturer SKU

PriceUsually
ships in
48" Included 8" 115 V Included 304481100 $13,37218-22 Days
48" Included 10" 115 V Included 304411100 $13,37218-22 Days
72" Included 8" 115 V Included 304681100 $15,75918-22 Days
72" Included 10" 115 V Included 304611100 $15,75918-22 Days
48" 8" 115 V 304480000 $12,25718-22 Days
48" 10" 115 V 304410000 $12,25725-29 Days
48" Included 8" 115 V 304480100 $12,81918-22 Days
48" Included 10" 115 V 304410100 $12,81918-22 Days
48" 8" 115 V Included 304481000 $12,81018-22 Days
48" 10" 115 V Included 304411000 $12,81018-22 Days
72" 8" 115 V 304680000 $14,62318-22 Days
72" 10" 115 V 304610000 $14,62318-22 Days
72" Included 8" 115 V 304680100 $15,21418-22 Days
72" Included 10" 115 V 304610100 $15,21418-22 Days
72" 8" 115 V Included 304681000 $15,17618-22 Days
72" 10" 115 V Included 304611000 $15,17618-22 Days
Width
Base Stand
Sash Opening
Voltage
UV Lamp
Manufacturer SKU
Item ordered before. Click on bagde to see the order.
Demo Available
Some ship in:
Usually Ships in:
Item is in stock and ready for immediate shipping
Free shipping in contiguous USA
Select product to see details

Product Details

• Class II Type C1 Biological Safety Cabinet: Convertible between a Type A (70% recirculating) or Type B (100% exhaust) biosafety cabinet

• For Biosafety Level (BSL) 1, 2, and 3 containment or BSL 4 with PPE

• Protects personnel, product and lab environment by maintaining complete containment in event of exhaust system failure

• Type A operation is suitable for microbiological and cell culture work

• Type B operation is suitable for chemotherapeutics, carcinogens and other hazardous chemicals

• Chem-Zone provides significant energy savings by only exhausting the critical work area and recirculating air in the staging areas on either side of the Chem-Zone

• Active Protection Protocol operates the exhaust blower for 10 seconds following normal shut down to prevent “puff-back”

• In the event of exhaust system failure, the Active Protection Protocol system will maintain containment despite increasing static pressure, providing time for emergency shutdown and evacuation

• MyLogic Operating System controls Smart-Start™ System allowing the user to start program and shut down operations and Night-Smart™ System for idling the blower when the sash is closed

• Default screen on LCD information center shows ""Filter Life Remaining"" bar graph

• ADA-compliant positioning of controls

• Equipped with both supply and exhaust HEPA filters

• Optional connection to in-house exhaust system for hazard removal (fumes, vapors, allergens, genetic material, carcinogens, or antineoplastic drugs)

Biosafety Cabinets

  • Interior View of Labconco’s Axiom™ Class II Type C1 BSC Interior View of Labconco’s Axiom™ Class II Type C1 BSC
  • Video by Labconco telling the story of the Type C1 Biosafety Cabinet's inception as a dual-type hood Development of the Type C1 Biological Safety Cabinet
  • Video by Labconco describing the features and benefits of the Axiom Type C1 biosafety cabinet Overview of Labconco's Purifier Axiom Type C1 Biosafety Cabinet
  • Animated walkthrough of the airflow patterns and features of the Purifier Axiom Type C1 biosafety cabinet Labconco Purifier Axiom Type C1 Biosafety Cabinet Airflow
Interior View of Labconco’s Axiom™ Class II Type C1 BSC
Video by Labconco telling the story of the Type C1 Biosafety Cabinet's inception as a dual-type hood
Video by Labconco describing the features and benefits of the Axiom Type C1 biosafety cabinet
Animated walkthrough of the airflow patterns and features of the Purifier Axiom Type C1 biosafety cabinet

Features & Benefits

Features and Benefits

Class II C1 BSC Features Explained


Purifier Axion Class II, Type C1 Biosafety Cabinets by Labconco







































































Nominal Width
4 feet
6 feet
Dimensions without Base Stand
4.2W x 32.7D x 69H in

(1380 x 830.58 x 1752.6 mm)
78.2"w x 32.6"d x 69"h

(1986.28 x 828.04 x 1752.6 mm)
Dimensions with Base Stand
54.2"w x 32"d x 96.5"h

(1377 x 812.8 x 2451.1 mm)
78.2"w x 32.6"d x 96.5"h

(1986.28 x 828.04 x 2451.1 mm)
Power Consumption
200 watts 325 watts
Exhaust Volume 10" Sash
480 CFM @ 0.2" s.p. 684 CFM @ 0.2" s.p.
Exhaust Volume 8" Sash
387 CFM @ 0.2" s.p. 556 CFM @ 0.2" s.p.
Shipping Weight (cabinet only)
750 lbs. (340 kg) 1075 lbs. (488 kg)
Shipping Weight (cabinet with stand)
835 lbs. (379 kg) 1175 lbs. (533 kg)
Compliance
ETL, Modified ASHRAE 110, NSF 49; CE available (inquire)
Lighting
Fluorescent
Electrical
115 volts, 60 Hz, 12 amps; 220 volts available (inquire)
Cabinet Class Standard
Meets Class 5 conditions per ISO 14644-1 and 2 (Class 100)
Warranty
5-Year Manufacturer Warranty























































Noise Levels and Exhaust at Varying Face Velocities
Nominal Width 100 FPM Face Velocity 80 FPM Face Velocity 60 FPM Face Velocity
Exhaust (CFM) db(A) Exhaust (CFM) db(A) Exhaust (CFM) db(A)
2 ft. 145 53-58 115 50-55 85 48-53
3 ft. 220 58-61 175 53-58 130 48-53
4 ft. 290 62-66 235 58-61 175 49-54






Chem-Zone Work Surface

The dished Chem-Zone™ Work Surface contains spills and features perimeter air-inlets that lead directly to the exhaust filter. Air captured within this zone will never be recirculated inside the hood, preventing the buildup of hazardous fumes.

Omni-Flex™ (Convertible Exhaust) Design

Converting between Type A and Type B operation is simple. Connect ductwork and install the plate on the left side of the exhaust collar (as shown) for Type B exhaust. Remove the ductwork and install the plate on the right side for Type A.

ADA-Compliant Touchpad Controls

The touchpad controls, mounted on the right-hand side of the hood, allow operators to manually toggle the blowers, lights, and power receptacles.

Inclined, Ergonomic Inlet Grille

The curved inlet grille provides comfortable support for the operator’s forearms while working within the hood. The airflow inlet pattern is designed to compensate for any airflow restrictions caused by the operator blocking the slots.

Hidden Power Receptacle

The cover to the electrical outlet is flush with the hood’s interior surface for easy cleaning. The hinges are dampened so that the cover closes gently when released.

Available Accessories

Popular Accessories

For a full list of accessories, select a product then click Choose Accessories on that product page.
  • Labconco Coated Steel Blower
    Constructed with a 304 stainless steel one-piece liner with coved corners, Protector Stainless Steel Radioisotope Hoods have no joints, crevices or cracks. Units effectively contain radiochemicals.
  • Labconco Telescoping Base Stand
    Ergonomically designed and energy efficient, these biosafety cabinets provide safety and comfort to users working with hazardous particulates that require Biosafety Level 1, 2 or 3 containment.
  • Labconco Purifier Logic Plus UV Sterilization Lamp
    A UV sterilization cycle provides secondary decontamination of the cabinet interior. The lamp is integrated with the hood's systems so that it can be controlled via the timer function and only activates when the sash is fully closed.
  • Hydraulic Lift Base Stand
    Unlike telescoping base stands that are locked in position, a hydraulic base stand can be adjusted as needed to best suit the heights of different operators.
  • Vacu-Pass™ Cord & Cable Port Kit
    Labconco's Vacu-Pass Cord & Cable Port allows power cords and vacuum tubing to enter the hood without compromising safety. Each port includes 4 closed-cell neoprene fittings with various diameter holes as well as a blank (cover) plug.
  • Service Fixtures
    Labconco's Service Fixture Kits are designed for easy installation in one of the designated mounting locations inside of a Labconco hood

Products similar to this one

Manuals & Resources

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.

Hide
You need at least 2 products to compare Compare Clear All