Select Product

Voltage

Frame Material

Depth

Duplex Outlet

Service Fixtures

Manufacturer SKU

Terra Part #PriceShips in
115 V Powder-Coated Steel 37.7" Installed Installed 180410002 3652-18 63422 Request Quote40-44 Days2
115 V Powder-Coated Steel 37.7" Installed Installed 180510002 3652-27 63431 Request Quote40-44 Days3
115 V Powder-Coated Steel 37.7" Installed Installed 180610002 3652-36 63440 Request Quote40-44 Days4
115 V Powder-Coated Steel 37.7" Installed Installed 180810002 3652-45 63449 Request Quote40-44 Days5
115 V Powder-Coated Steel 37.7" Installed Installed 181410002 3652-21 63425 Request Quote40-44 Days6
115 V Powder-Coated Steel 37.7" Installed Installed 181510002 3652-30 63434 Request Quote40-44 Days7
115 V Powder-Coated Steel 37.7" Installed Installed 181610002 3652-39 63443 Request Quote40-44 Days8
115 V Powder-Coated Steel 37.7" Installed Installed 181810002 3652-48 63452 Request Quote40-44 Days9
115 V Powder-Coated Steel 37.7" Installed Installed 182410002 3652-24 63428 Request Quote40-44 Days10
115 V Powder-Coated Steel 37.7" Installed Installed 182510002 3652-33 63437 Request Quote40-44 Days11
115 V Powder-Coated Steel 37.7" Installed Installed 182610002 3652-42 63446 Request Quote40-44 Days12
115 V Powder-Coated Steel 37.7" Installed Installed 182810002 3652-51 63455 Request Quote40-44 Days13
115 V Powder-Coated Steel 37.7" Optional Installed 180410001 3652-17 63421 Request Quote40-44 Days14
115 V Powder-Coated Steel 37.7" Optional Installed 180510001 3652-26 63430 Request Quote40-44 Days15
115 V Powder-Coated Steel 37.7" Optional Installed 180610001 3652-35 63439 Request Quote40-44 Days16
115 V Powder-Coated Steel 37.7" Optional Installed 180810001 3652-44 63448 Request Quote40-44 Days17
115 V Powder-Coated Steel 37.7" Optional Installed 181410001 3652-20 63424 Request Quote40-44 Days18
115 V Powder-Coated Steel 37.7" Optional Installed 181510001 3652-29 63433 Request Quote40-44 Days19
115 V Powder-Coated Steel 37.7" Optional Installed 181610001 3652-38 63442 Request Quote40-44 Days20
115 V Powder-Coated Steel 37.7" Optional Installed 181810001 3652-47 63451 Request Quote40-44 Days21
115 V Powder-Coated Steel 37.7" Optional Installed 182410001 3652-23 63427 Request Quote40-44 Days22
115 V Powder-Coated Steel 37.7" Optional Installed 182510001 3652-32 63436 Request Quote40-44 Days23
115 V Powder-Coated Steel 37.7" Optional Installed 182610001 3652-41 63445 Request Quote40-44 Days24
115 V Powder-Coated Steel 37.7" Optional Installed 182810001 3652-50 63454 Request Quote40-44 Days25
115 V Powder-Coated Steel 37.7" Optional Optional 180410000 3652-16 63420 Request Quote40-44 Days26
115 V Powder-Coated Steel 37.7" Optional Optional 180510000 3652-25 63429 Request Quote40-44 Days27
115 V Powder-Coated Steel 37.7" Optional Optional 180610000 3652-34 63438 Request Quote40-44 Days28
115 V Powder-Coated Steel 37.7" Optional Optional 180810000 3652-43 63447 Request Quote40-44 Days29
115 V Powder-Coated Steel 37.7" Optional Optional 181410000 3652-19 63423 Request Quote40-44 Days30
115 V Powder-Coated Steel 37.7" Optional Optional 181510000 3652-28 63432 Request Quote40-44 Days31
115 V Powder-Coated Steel 37.7" Optional Optional 181610000 3652-37 63441 Request Quote40-44 Days32
115 V Powder-Coated Steel 37.7" Optional Optional 181810000 3652-46 63450 Request Quote40-44 Days33
115 V Powder-Coated Steel 37.7" Optional Optional 182410000 3652-22 63426 Request Quote40-44 Days34
115 V Powder-Coated Steel 37.7" Optional Optional 182510000 3652-31 63435 Request Quote40-44 Days35
115 V Powder-Coated Steel 37.7" Optional Optional 182610000 3652-40 63444 Request Quote40-44 Days36
115 V Powder-Coated Steel 37.7" Optional Optional 182810000 3652-49 63453 Request Quote40-44 Days37
Voltage
Frame Material
Depth
Duplex Outlet
Service Fixtures
Manufacturer SKU
Item ordered before. Click on bagde to see the order.

Up to 30-day trial periods, free return shipping and on-site training available for qualified equipment.

Request demo from your product specialist or add note to your order or quote request.

Some ship in:
Usually Ships in:
Item is in stock and ready for immediate shipping
Free shipping in contiguous USA
Custom-configured product: Terra will quote.
Custom-configured product: Terra will quote.
Select a product line for product summary

Product Details

• High-tech ductless fume hoods for safe, energy efficient and adaptable containment

• Neutrodine filters provide broad chemical adsorption capability, eliminating the need for filter selection and specific filter combinations

• Dual-filter design provides backup containment for filter breakthrough, with safety sensor “sandwiched” in between

• Optional HEPA filters remove sub-micron particulates from the exhaust airflow

• No ductwork required; saves energy by recirculating the room-temperature air

• Erlab's GreenFumeHood® (GFH) Filtration Technology incorporates “watch-dog” software that scans for system failures and safety issues

• Erlab's Neutrodine Filters simultaneously handle solvents, acids, bases, ammonia and formaldehyde

• Each filter is accompanied by its own blower module to ensure sufficient airflow

• Radio frequency identification (RFID) cards prevent unauthorized personnel from operating the hood

• Vertical-rising sash uses a counterweighted pulley system for smooth opening/closing

• Sash-stop installed at 16"" recommended sash opening height; Sash opens to 28"" high for loading

• Eco-Foil™ Air Foil with aerodynamic Clean-Sweep™ airflow openings ensure smooth air inflow along the sash opening

• Chemical-resistant, fiberglass-reinforced composite interior liner

• Removable front and side panels, as well as access panels for service fixtures (except side window models)

• Factory-prepared for up to four electrical duplex receptacles and eight service fixtures

• Factory-installed control panel with digital display, fan button and light button

Sound pressure of <60 dBA with sash at operating height and <48 dB(A) with sash closed

• Pre-wired vapor-proof fluorescent lighting

• Meets and exceeds the SEFA 9-2010 DH III definition for a filtered fume hood

Fume Hoods by Labconco

  • Video overview webinar by Labconco sales associate pitching the Protector Echo Filtered Fume Hood Overview of Labconco's Protector Echo Fume Hood
  • Protector Echo Benchtop Filtered Fume Hood includes back, side windows with model Protector Echo Benchtop Filtered Fume Hood
Video overview webinar by Labconco sales associate pitching the Protector Echo Filtered Fume Hood
Protector Echo Benchtop Filtered Fume Hood includes back, side windows with model

Features & Benefits

Features and Benefits

How to Choose the Right Fume Hood for Your Lab

Fume Hood Frequently Asked Questions

Selecting the appropriate fume hood or ductless exhaust hood, ensuring operator protection, and maintaining optimum hood performance can be a monumental task. Asking the right questions will help drive your decision-making process toward the right system for your application and support your standard operating procedures in maintaining a safe environment.

Does my work require a fume hood?

Use of a chemical fume hood is required to enclose work involving toxic gasses, reactive or explosive materials, volatile chemicals, carcinogens, flammable chemicals, hazardous substances and processes producing aerosols or nuisance odors.

What’s the difference between a ducted fume hood and a ductless exhaust hood?

Exhaust fume hoods vent air from the work area directly outside of the building by connecting to the facility’s ducted exhaust system. Ductless exhaust, or stand-alone, fume hoods use integral blowers to draw air away from the work area through a set of filters before safely releasing the air back into the ambient lab. Ductless hoods commonly use a two-stage filtration system composed of a charcoal filter for vapor containment and a final HEPA filter for particle containment. Charcoal filters capture chemical vapors with varying degrees of efficiency; review your list of chemicals - along with solvent concentrations and aliquoted volumes - with your fume hood specialist to ensure the appropriate filter is purchased. Laboratory fume hoods are required to safely enclose chemicals, such as methanol, that are not captured efficiently by charcoal filtration. Small-footprint ductless fume hoods fit onto crowded benchtops or into areas of the lab without access to the facility exhaust system. The effectiveness of a ductless exhaust hood is contingent upon regular filter maintenance; talk to your hood specialist or EH&S representative to prepare a standard filter replacement schedule.

What’s the difference between DH I, DH II, and DH III?

These acronyms define the different types of ductless hoods outlined by The Scientific Equipment and Furniture Association (SEFA):

  • Ductless Hood I (Type I): These light duty exhaust hoods are equipped with filtration only suitable for non-toxic chemicals, nuisance odors and particulates. They are not required to have a warning sensor for chemical breakthroughs.
  • Ductless Hood II (Type II): This type of fume hood meets all DH I requirements, and can filter manufacturer approved toxic contaminants, making it suitable for toxic or hazardous applications. It also includes a chemical detection sensor and alarm in the event of chemical breakthrough beyond the filter. However this design does not provide secondary containment in the event the primary filter fails.
  • Ductless Hood III (Type III): This filtered fume hood is equivalent to a DH II with the added benefit of backup secondary filtration that is the same type and efficiency as the primary filter. DH III hoods also include a sensor between the primary and secondary filter, to ensure secondary filtration is available in case the primary filter fails.
Do I need a light duty chemical hood or a high-performance fume hood?

Although the primary purpose of a laboratory fume hood is operator safety, demand has increased for hoods designed to carry lower operating costs and reduced environmental impact. As fume hoods consume an average of 70,000 cubic feet of pre-conditioned air per hour, their operating costs are tied primarily to their air consumption, cited as volumetric rate (CFM) or face velocity (fpm). High-performance fume hoods - also called green ventilation hoods, high efficiency hoods or low-flow hoods – provide the highest level of containment at the lowest operating cost. High-performance fume hoods are designed to safely operate while maintaining a face velocity of 60 fpm, the lowest acceptable ASHRAE performance standard as outlined by SEFA. In addition to reduced face velocities, high efficiency fume hoods can integrate with Variable Air Volume (VAV) building automation systems to ensure minimum allowable room air changes, safe room pressurization and desirable temperature and humidity set points. A conventional light-duty, or by-pass, fume hood carries a lower up-front cost than a high-performance hood, but does not include design features allowing for reduced air volume ventilation or VAV integration. Most light-duty exhaust hoods safely operate at face velocities between 90 – 110 fpm, equal to an increase in air consumption of 30 – 50% annually. To decide between a light-duty chemical hood and a high-performance fume hood, a life cycle cost analysis is required to compare energy cost, ambient climate conditions and usage rate.

Does my work require a benchtop fume hood, walk-in hood or canopy hood?

Bench top fume hoods are mounted on an existing work surface, or casework, to create a negative-pressure environment for fume containment. A walk-in fume hood, or floor-mounted hood, includes no work surface or cabinetry, allowing the user to place large items into the hood at floor level. A canopy fume hood is installed on the wall or suspended from the ceiling; it does not include a hood frame or physical barrier between the fume hood area and the ambient lab. Benchtop fume hoods are designed to enclose singular processes on a crowded benchtop, like small-scale solvent evaporation or ethanol extraction. Walk-in fume hoods can accommodate bulk storage systems, like 50-gallon drums, large processing equipment and heavy items transported by lab carts. Canopy exhaust hoods are designed to vent non-toxic materials like heat, steam and nuisance odors emanating from ovens, steam baths or autoclaves.

Should I purchase a remote blower or dedicated, built-in blower with my lab fume hood?

Built-in blowers, or exhaust fans, are installed within the body of the fume hood and positioned above the work area. Remote exhaust blowers are installed on the building exterior and connect to the fume hood through a duct system. Built-in blowers are easier to install and less expensive, but can be noisy. As integral, built-in blowers can place sections of the ductwork under positive pressure, thus pushing contaminants through duct leaks back into the lab, they are recommended for non-hazardous applications, short duct runs, or mobile labs. Remote blowers, though more expensive and complex to install, can be sized for the specific situation, taking into account the duct diameter and run length and quantity of 90-degree or 45-degree elbow turns. Remote blowers keep the ductwork under constant negative pressure; any leaks in the duct system will draw air into the duct for exhaust from the building. Remote blowers include exhaust stacks and zero-pressure weather caps, ensuring the exhausted air is terminated at least 10 feet above the roofline to prevent fumes from returning to the building through the HVAC system.

Which blower should I choose for a ducted fume hood?

To maintain the safety and containment of your lab hood, selecting the proper motor blower is critical. Exhaust blowers are composed of three materials: steel, fiberglass and polyvinyl chloride (PVC). Review your chemical list with your fume hood specialist; steel blowers are designed for low-to-moderate corrosives, fiberglass blowers resist harsh solvent and acids, and PVC blowers can withstand exposure to high corrosives, such as perchloric acid. To determine the proper blower size, or capacity, you must calculate your fume hood resistance, measured is static pressure loss. Fume hood resistance is calculated by accounting for hood face velocity, volumetric rate and static pressure along with exhaust duct diameter, number of duct turns, operating temperature, and facility altitude. Talk to your laboratory hood specialist to calculate your hood resistance and determine an appropriate blower size. Most blowers can safely maintain airflow between 250 – 3,500 CFM.

If I’m working with flammable chemicals, do I need an explosion-proof hood?

Not necessarily. All fume hood electrical components are mounted on the corner posts, outside of the flammable vapor trail. Additionally, air constantly exhausting through the work area continually dilutes the air inside the fume hood, creating conditions under which few chemicals reach their lower explosive or flammability limits, according to the NFPA (National Fire Protection Association). Explosion-proof fume hoods are required if a flammable chemical’s concentration exceeds 25% of the LEL (Lower Explosion Limit) or LFL (Lower Flammability Limit). Talk to your fume hood specialist to calculate your dilution factor and volumetric air flow rate, along with each chemical’s LEL and LFL, to determine if an explosion-proof hood is required.

How do you organize the work area inside a fume hood?

In general, the work area should only contain supplies and reagents dedicated to ongoing experiments. If you must store equipment - such as balances, centrifuges, hot plates or rotary evaporators - inside the fume hood, please ensure the equipment is located away from the rear air baffles and elevated at least 2” off the work surface. Any equipment, sample racks, or consumables positioned downstream of an experiment may block contaminants from safe exhaust, reducing the effectiveness of the fume hood. All open chemicals must be placed at least 6 inches from the front edge of the fume hood airfoil to prevent eddy currents from pushing the vapors through the front of the hood face.

How can I reduce eddy currents in my work zone?

Eddy currents are sporadic, turbulent airflow patterns generated by disruptions inside the work area or at the hood face. Limiting eddy currents are vital to maintaining containment and operator protection. Keep lab doors and windows closed to prevent extra sources of air from sweeping across the hood face. Restrict personnel traffic near the hood when the shield is raised to prevent cross-drafts. Electrical cords, gas hoses or water lines running into the hood must be inserted underneath the air foil or through petcock connections to ensure the hood shield closes properly.

Labconco Protector Echo Filtered Fume Hood Neutrodine Filter

Neutrodine Filters by Erlab are environmentally friendly, constructed from layers of plant-based carbon materials infused with non-toxic agents. Test results showed that these filters are efficient on over 500 chemicals at various concentrations.

Labconco Protector Echo – Access Card Reader

Labconco’s Protector Echo Series features enhanced safety protocols, including an RFID card system for controlling access to the hood.

Dedication to Business Ethics

Terra is committed to conducting business according to the highest standard of professional ethics and conduct. To review Terra’s ethics code, please visit: https://www.terrauniversal.com/ethics-policy/

Available Accessories

Popular Accessories

For a full list of accessories, select a product then click Choose Accessories on that product page.
  • Labconco Spillstopper Work Surfaces
    These dished work surfaces are made of corrosion-resistant epoxy resins for durability and a smooth finish. Pass-through holes for venting and plumbing are predrilled into the rear portion of the surface (cut-outs for cup-sinks are optional).
  • Labconco Acid Storage Cabinet
    Acid storage cabinets are constructed of epoxy-coated steel with a corrosion-resistant, polyethylene interior coating. Each cabinet can support up to 800 lbs. and includes a vacuum-formed PVC tray to contain spillage inside the cabinet.

Products similar to this one

Other products you may find relevant
  1. Enclosed Safety Shower provides full-body and eye wash while protecting the lab against water and chemical runoff  |  1530-50A displayed
    Some ship in 1 - 3 days
  2. Provides a visual self-check to enhance compliance with gowning protocol  |  5252-74 displayed
    Some ship in 20 - 25 days
  3. Stainless steel BioSafe Cleanroom Clipboards provide non-shedding, durable, conductive surfaces, ideal for aseptic environments  |  1350-00A-2 displayed
    Some ship in 1 - 3 days
  4. Palm-Sized Temperature/Humidity Meters available with built-in or probe sensors  |  1401-17 displayed
    Some ship in 10 - 16 days
  5. 24-Gallon stainless steel BioSafe waste receptacle with a hands free foot pedal.  |  1456-18B displayed
    Some ship in 1 - 3 days
  6. ValuLine Stainless Steel Waste Receptacles come in 5 different sizes
    Some ship in 1 - 3 days
  7. PureFlow Laminar Transport Cart system provides an uninterrupted vertical laminar flow of HEPA-filtered air in the storage area  |  1529-68 displayed
    Some ship in 1 - 3 days
  8. Yellow Slimline safety cabinets by Justrite are fire resistant double wall, air insulated and welded steel construction  |  1619-90 displayed
    Some ship in 8 - 12 days
  9. Sure-Grip EX deep SlimLine safety cabinets provides OSHA-, NFPA-compliant protection and containment of flammable materials  |  1618-21 displayed
    Some ship in 8 - 12 days
  10. The Portable CleanBooth™ wheels into position above a workbench or equipment to provide an ISO 5-compliant flow of HEPA-filtered air (flexible side panels and f  |  1870-03A displayed
    Some ship in 1 - 3 days
  11. This all-stainless Steel Security Cabinet features a lock with fingerprint scanner for secure storage of pharmaceuticals  |  1989-10 displayed
    Some ship in 1 - 3 days
  12. Ionizing bars neutralize surface static charges, protecting sensitive materials and preventing particle buildup due to static cling
    Group of 4 products
    Ionizing Bars From
    $456
    Some ship in 1 - 3 days
  13. This Ionizing Blow-off Gun neutralizes static surface charges and removes particles with a burst of clean air or nitrogen  |  2005-55 displayed
    Some ship in 1 - 3 days
  14. The MAGNEHILIC® gauge measures and displays pressures; range of model shown: 0 - 1" WC  |  2625-30 displayed
    Some ship in 1 - 3 days
  15. Different size membrane Nitrogen generator options are available to meet your N2 gas supply needs
    Some ship in 1 - 3 days
  16. Terra's BioSafe® 304 Stainless Steel Footrests stand up to harsh cleaning agents and provide a firm foot platform while working
    Some ship in 1 - 3 days
  17. Corrosive Storage by Justrite features two manual stainless steel doors with 3-point stainless steel bullet latching system  |  2820-09A displayed
    Some ship in 8 - 12 days
  18. PureDry™ Recirculating Hand Dryers feature ULPA filtration and an integral air return that captures moisture
    Some ship in 1 - 3 days
  19. Polypropylene chemical transport cart with 12 compartments to transfer 1-gallon jugs and bottles filled with acids and other corrosives  |  3401-00 displayed
    Some ship in 1 - 3 days

Buy Accessories

Manuals & Resources

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.