120 V ISO 5 48" 30" 42" 15" 304 Stainless Steel Solid Wall Ductless Ventilation 46" 28" 28" 1675-58-48 80585 $3,912 10-12 Days 2
In stock
120 V ISO 5 36" 30" 42" 15" 304 Stainless Steel Solid Wall Ductless Ventilation 34" 28" 28" 1675-58-36 80584 $3,698 10-12 Days 3
In stock
120 V ISO 5 60" 30" 42" 15" 304 Stainless Steel Solid Wall Ductless Ventilation 58" 28" 28" 1675-58-60 81420 $4,847 10-12 Days 4
In stock
120 V ISO 5 72" 30" 42" 15" 304 Stainless Steel Solid Wall Ductless Ventilation 70" 28" 28" 1675-58-72 80586 $5,781 10-12 Days 5
In stock
Voltage
Certified ISO Grade Design
Width
Depth
Height
Sash Opening
Hood Material
Model
Inside Width
Inside Depth
Inside Height
Item ordered before. Click on bagde to see the order.

Up to 30-day trial periods, free return shipping and on-site training available for qualified equipment.

Request demo from your product specialist or add note to your order or quote request.

Some ship in:
Usually Ships in:
Free shipping in contiguous USA
Custom-configured product. Contact Terra by phone, chat or email for a project-specific quote.
Custom-configured product. Contact Terra by phone, chat or email for a project-specific quote.
Select a product line for product summary
Product Details
Product Details
  • Available ISO Rated Designs: ISO 5, ISO 6, ISO 7, ISO 8
  • Enclosed work area improves ventilation performance
  • Stainless steel construction offers durability and easy-to-clean surfaces
  • Heavy-duty, stainless steel knobs control the LED lights and blower
  • Includes hinged access shield that increases air speed by restricting the air exhaust
  • Open-bottom design for versatility; work surface not included

BioSafe Universal Ventilation Hoods

  • ISO 5 BioSafe Flowhood Watch Terra's BioSafe® Universal Benchtop Hoods Video
  • Vibration isolation stand adjustable video Watch Terra's Vibration Isolation Stand Video
  • Adjustable isolation stand Vibration Isolation Stand
  • ErgoHeight® workstations Watch Terra's ErgoHeight® Workstations Video
  • Terra Universal WhisperFlow Laminar Flow Hoods Terra Universal WhisperFlow Laminar Flow Hoods
  • Laminar Flow Hood Smoke Test
  • Horizontal Laminar Flow Hood Smoke Test
  • Vertical laminar flow hood mounted on automatic height adjusting table Benchtop ISO 5 Vertical Laminar Flow Hood with Automatic Height Adjusting Table
ISO 5 BioSafe Flowhood
Vibration isolation stand adjustable video
ErgoHeight® workstations
Terra Universal WhisperFlow Laminar Flow Hoods
Features & Benefits

Features and Benefits

Learn More: Laminar Flow and Fume Hoods

Laminar Flow and Fume Hoods FAQs

Laboratory hoods serve a number of critical purposes in the lab environment.

Product protection from particulate contaminants in the lab environment, including microbes

Such hoods, often called laminar flow workstations or clean benches, use a flow of HEPA-filtered air to prevent influx of viable and non-viable particles into the enclosure and to sweep away any contaminants generated by the work process.

Protection of personnel and lab environment from substances generated inside the enclosure

For fume containment, laboratory fume hoods use a ducted ventilation system that maintains negative pressure. Where ducting is impractical, ductless hoods are also available for removal of non-hazardous contaminants (fumes or particles), using either HEPA or activated carbon filters.

Protection of product, operator and environment

Biological safety cabinets combine aspects of both hood types: a laminar flow of micro-filtered air and negative-pressure containment of bio-hazard fumes.

Laminar Flow Hoods

Laminar flow hoods (also called laminar flow clean benches) force air through a HEPA or ULPA filter to create a clean work area free of nearly all contaminating particulates, including bacteria, mold spores and many viruses. These hoods use a vertical or horizontal airflow design. Both provide excellent protection of products from particulates and cross-contamination, but do not protect the operator or environment.

So why choose one over the other? Vertical laminar flow hoods (VLF Hoods) require less floor space, but more overhead clearance. In addition, a sash at the front of the VLF hood provides a barrier between air exiting the hood and the operator’s face. VLF hoods create turbulent air flow when air strikes the work surface, requiring sterile work to be performed above the work surface.

HLF hoods minimize air turbulence (and particle backflow) on the work surface except where equipment disrupts the horizontal airflow. However, they direct the airflow directly at the operator’s face and require more depth to accommodate placement of the fan filter unit at the rear of the hood.

Read more about the differences between horizontal and vertical laminar flow hoods

Fume Exhaust Hoods

Laboratory fume hoods draw air from the environment through the opening of the hood, allowing environmental contaminants into the work area. Thus, lab fume hoods do not offer a sterile environment or product protection. Instead, chemical fume hoods are designed to protect the operator from dangerous or irritating fumes and powders generated from work performed inside the hood.

In ducted fume hoods and canopy fume hoods, air passes out of the hood through a duct leading to an in-house ventilation system that contains and/or neutralizes hazardous materials.

In ductless fume hoods, fans draw exhaust air through a series of filters that remove irritating substances before release back into the room. Since these filters are not 100% efficient in removing all substances, ductless fume hoods are not advised in the presence of biohazards; however, they provide a convenient, cost-effective solution for operations involving irritating but non-hazardous fumes in facilities where an in-house HVAC system cannot be accessed.

Biosafety Cabinets

Biological Safety cabinets combine design aspects of both laminar flow and fume hoods. Filtered air is directed downward onto the work surface and then travels into a plenum through openings on the front and sides of the hood. Depending on the classification of the biosafety hood, some percentage of air is recirculated through a HEPA filter while the rest is directed out of the hood through an exhaust system. Thus, biosafety cabinets offer operator, environmental and product protection.

These laboratory safety cabinets (sometimes called IV hoods or compounding hoods) are ideal when preparing sterile medications such as chemotherapeutic agents that may pose a risk to the operator.

BSCs, BSLs, and ISO Classes

When it comes to working with hazardous or potentially infectious material, protecting personnel must be the primary concern. However, offering personnel protection does not have to come at the cost of risking product integrity. Class II BSCs provide protection to both personnel and product simultaneously. They maintain an ISO class 5 clean work area for product manipulation, while ensuring that exhaust air is filtered and ducted out of the environment. Thus, a class II BSC is the ideal solution when working with moderately hazardous material and both personnel and product safety are required.

Read more about these lab hoods here regarding their biological safety rating

Critical Environment Solutions

Terra's mission is to help customers in highly regulated industries transform the world with critical environment solutions that improve health, safety, performance, and yields. These environments may comply with stringent UL, ISO, IEST, ASTM and OSHA standards and local requirements.

BioSafe® WhisperFlow Hoods: One-Piece Design With Seamless Tracks

BioSafe® Whisper Flow Hoods feature a one-piece design free of cracks or crevices that harbor microbes and contaminants. Surface are easy to wipe down, resistant to alcohol-based cleaners and harsh biocides.

HEPA-Filtered Reverse Flow Fan Unit

High Efficiency Particulate Air (HEPA) Filter Fan Unit provides clean micro-filtered air, shown in reverse-flow hood that captures contaminants generated in the work area for safe cleanroom release.

Recessed LED Lighting Illuminates Work Area

Laminar flow hoods include long-lasting LED lighting to illuminate the work area. The LED strip is flush-mounted for easy disinfection.

Versatile Removable Panels

Removable side-panels increase the versatility of your hood by improving visibility plus simplifying equipment access. The side-panels are lined with foam gasket and slide into the hood’s frame for a simple yet effective seal. Each panel is easily removed to simplify cleaning and disinfection.

Tilt-Up Sash

Tilt-up sash enhances laminar airflow and prevents air from blowing directly at the operator’s face. Static-dissipative PVC material resists chemicals and eliminates particle attraction from static charges.

Integrated Status Indicator Light

Operation status indicator (OSI) light glows continuously when hood is plugged in and turned on to confirm filtration unit is operational. The OSI blinks when the unit is plugged in but switched off.

BioSafe®: Terra's Ultimate Cleanliness Rating

Terra's BioSafe products are designed for the most critical applications: no gaps and crevices where microbes colonize, rounded corners for easy disinfection, won't produce contaminants during sterilization, and exceeds cGMP, IEST, ASTM and ISO 14644-1 requirements.

Highest Standards For Electronic Components

Terra’s electronic components are designed and built to the highest standards required by defense and semiconductor industries for long-term reliability and protection against damage, injuries, and electrical hazards.

Continuous Product Improvement

At Terra, we strive to develop and produce the highest quality products for our customers to improve health, safety, performance, and yields. Our product quality is enabled by high-grade manufacturing equipment and processes, 45 years of engineering and application expertise, and our commitment to continuously improve.

Global Customer Base

At Terra, we are committed to providing top-tier equipment to customers throughout the world. Over the past 5 years, clients in over 100 countries have purchased equipment from Terra.

Top-Tier Clients

Terra’s key customers include some of the largest research labs, production facilities and universities in the world

Industry-Leading Product Quality

At Terra, we strive to produce the highest quality products for our customers. Our product quality is enabled by high-grade manufacturing equipment, over 45 years of engineering expertise, and our commitment to continuously improve.

Terra's QuickBuild Program

Build your system using in-stock components and accessories. We’ll assemble your system, package and ship your order in 6 business days.

Products Tailored to Your Cleanroom Environment

Provide Terra with your desired ISO Grade™ design. We will tailor the product to meet your criteria and certify it with a report appended to your invoice. Certificate includes all the necessary information to streamline audits and facility compliance.
Available Accessories
Popular Accessories
For a full list of accessories, select a product then click Choose Accessories on that product page.
  • Vibration Isolation Stand

    Width and height adjustable stand supports the user on vibration sensitive applications by isolating their equipment from the work surface
  • Benchtop Fume Hood with Automatic Height Adjusting Table

    Benchtop fume hoods help ventilate and remove chemical fumes and particles, allowing for safe indoor release of exhaust. They can also easily mount to an automatic height adjusting table (28”-43”H). Perfect for workstations with heavy or fragile equipment.
  • Vapor-Sealed Fluorescent Illuminator

    This fluorescent light fixture is enclosed in a vapor-sealed, static-dissipative PVC housing to protect the light source from dust, dirt, and vapors. The housing extends the useful life of the light fixture and provides an easy-to-clean surface.
  • Vibration-Isolated Table

    Works surface and stand pair provide vibration-isolated solution for Biosafe Universal Hoods
  • UV Germicidal Lamp

    The V-Ray germicidal UV lamp is installed within a Terra hood to inhibit microbial growth on the work surface
Products similar to this one
Buy Accessories
Manuals & Resources

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.