Hood; ValuLineā„¢ Vertical Laminar Flow Station, 304 Stainless Steel, Static-Dissipative PVC, 100" W x 32" D x 91" H, 120 V, Attached Table
Product Details
  • Available ISO Ratings: ISO 7, ISO 8
  • Provides a particle-free environment for contamination-sensitive work
  • Dissipative PVC side panels help maintain a laminar flow of HEPA filtered air
  • Tilt-up dissipative PVC sash lets the operator adjust the access area
  • Includes FDA-approved silicone sealant; specify alternative sealant if needed
  • ValuLineā„¢ Hoods cannot be customized
  • Internal baffling plates and anodized aluminum diffuser panel ensure uniform air speed across the filter face
  • Turnkey system comes complete with HEPA FFUs, lighting, SS work surface, tilt-up sash, and GFI outlet
  • Because the attached workstation transmits fan vibration, this design is NOT suitable for delicate operations with scales, balances, and other precision instruments; select Terraā€™s VLF Workstation instead
  • Included Power Integration Module features switching and breaker protection for all electrical components
  • Operation Status Indicator that flashes if fan is not operational

ā€¢ Filter Type: HEPA

ā€¢ Side Panels: Static-Dissipative PVC

ā€¢ Inside Width: 96.95"

ā€¢ Inside Height: 36.75"

ā€¢ Inside Depth: 30"

ā€¢ Light Fixture: Fluorescent

ā€¢ Sash Opening: 10.25"

ā€¢ Sash Height: 23.5"

ā€¢ Work Area Dimensions: 96.95" W x 30" D x 36.75" H

ā€¢ Max Opening: 33.75" H

ā€¢ Hood Design: Floor

ā€¢ Height: 91"

ā€¢ Manufactured by: Terra Universal

ā€¢ Airflow Design: Vertical

ā€¢ Frame Material: 304 Stainless Steel

ā€¢ Width: 100"

ā€¢ Depth: 32"

ā€¢ Electronic Air Speed Control: No

ā€¢ Model: ValuLineā„¢ Vertical Laminar Flow Station

ā€¢ Certified ISO Graded Design: ISO 7

ā€¢ Available Certified ISO Graded Designs: ISO 7, ISO 8

ā€¢ Table Configuration: Attached

ā€¢ Unit of Measure: EA

ā€¢ Marks & Listings: UL, ULC

ā€¢ Electrical Specifications: 120 V, 7.5 A, 1,800 W, 50/60 Hz

ā€¢ Weight, Product: 553 lb

ā€¢ Dimensions, Product: 100" W x 32" D x 91" H

ā€¢ Weight, Shipping: 1,007 lb

ā€¢ Dimensions, Shipping: 106" W x 38" D x 99" H

ā€¢ Package Type: Crate

Buy Accessories
  1. Shown: Vacupass installed in the interior wall of a biosafety cabinet  |  4642-49 displayed
    Vacu-Pass; Cord and Cable Port Kit, 3.5"Dia x 2.875"L Quick Ship+ Available 928 in stock
    $213
    Increase Down Increase Up
  2. Provides a stream of static-neutralizing ions to protect ESD-sensitive components.
    Ion Bar, 44", 8 Emitters, Uninstalled, 120 V Quick Ship+ Available In stock
    $969
    Increase Down Increase Up
  3. Service, ISO Gradeā„¢ Certificate, ISO 7
    Request Quote
    Increase Down Increase Up
  4. Service; UL Listing Declaration, for Laminar Flow and Fume Hoods
    Request Quote
    Increase Down Increase Up
  5. Warranty; 3 Year, Hood, Parts
    Request Quote
    Increase Down Increase Up
  6. Warranty; 2 Year, Hood, Parts
    Request Quote
    Increase Down Increase Up
  7. FasTrak 24-7 Expediting Service
    Request Quote
    Increase Down Increase Up
  8. Qualification Documentation (IQ/OQ) for Terra Universal System
    Request Quote
    Increase Down Increase Up
  9. White Glove Freight Service
    Request Quote
    Increase Down Increase Up
  10. Equipment Testing
    Request Quote
    Increase Down Increase Up
  11. High Efficiency Particle Filter is rated  99.99% efficient @ 0.3 Āµm diameter particles  |  6601-25 displayed
    Filter; HEPA, 2'x4', Aluminum, Rated 99.99% efficient Quick Ship+ Available 1734 in stock
    $616
    Increase Down Increase Up
  12. High Efficiency Particle Filter is rated  99.99% efficient @ 0.3 Āµm diameter particles  |  6601-25 displayed
    $635
    Increase Down Increase Up
  13. MERV 7 pre-filter for Terra Fan Filter Units (FFUs)), 4 pack  |  6601-34 displayed
    $170
    Increase Down Increase Up
  14. MERV 7 pre-filter for Terra Fan Filter Units (FFUs)), 12 pack  |  6603-84 displayed
    $454
    Increase Down Increase Up
  15. WhisperFlow Fan/Filter Units feature internal baffling and anodized aluminum diffuser panels provide quiet, uniform air fow  |  6601-24-H displayed
    $836
    Increase Down Increase Up

ValuLineā„¢ Vertical Laminar Flow Workstations

  • Terra Universal WhisperFlow Laminar Flow Hoods Terra Universal WhisperFlow Laminar Flow Hoods
  • Laminar Flow Hood Smoke Test
  • High-Clearance, Wide-Access Vertical Laminar Flow Hoods ValuLineā„¢ Vertical Laminar Flow Stations
  • Vertical Laminar Flow Tilt-Up Shield Tilt-Up Shield
  • Powder-Coated Steel Laminar Flow Hood ValuLineā„¢ Vertical Laminar Flow Station
Terra Universal WhisperFlow Laminar Flow Hoods

Features and Benefits

Learn More: Laminar Flow and Fume Hoods

Laminar Flow and Fume Hoods FAQs

Laboratory hoods serve a number of critical purposes in the lab environment.

Product protection from particulate contaminants in the lab environment, including microbes

Such hoods, often called laminar flow workstations or clean benches, use a flow of HEPA-filtered air to prevent influx of viable and non-viable particles into the enclosure and to sweep away any contaminants generated by the work process.

Protection of personnel and lab environment from substances generated inside the enclosure

For fume containment, laboratory fume hoods use a ducted ventilation system that maintains negative pressure. Where ducting is impractical, ductless hoods are also available for removal of non-hazardous contaminants (fumes or particles), using either HEPA or activated carbon filters.

Protection of product, operator and environment

Biological safety cabinets combine aspects of both hood types: a laminar flow of micro-filtered air and negative-pressure containment of bio-hazard fumes.

Laminar Flow Hoods

Laminar flow hoods (also called laminar flow clean benches) force air through a HEPA or ULPA filter to create a clean work area free of nearly all contaminating particulates, including bacteria, mold spores and many viruses. These hoods use a vertical or horizontal airflow design. Both provide excellent protection of products from particulates and cross-contamination, but do not protect the operator or environment.

So why choose one over the other? Vertical laminar flow hoods (VLF Hoods) require less floor space, but more overhead clearance. In addition, a sash at the front of the VLF hood provides a barrier between air exiting the hood and the operatorā€™s face. VLF hoods create turbulent air flow when air strikes the work surface, requiring sterile work to be performed above the work surface.

HLF hoods minimize air turbulence (and particle backflow) on the work surface except where equipment disrupts the horizontal airflow. However, they direct the airflow directly at the operatorā€™s face and require more depth to accommodate placement of the fan filter unit at the rear of the hood.

Read more about the differences between horizontal and vertical laminar flow hoods

Fume Exhaust Hoods

Laboratory fume hoods draw air from the environment through the opening of the hood, allowing environmental contaminants into the work area. Thus, lab fume hoods do not offer a sterile environment or product protection. Instead, chemical fume hoods are designed to protect the operator from dangerous or irritating fumes and powders generated from work performed inside the hood.

In ducted fume hoods and canopy fume hoods, air passes out of the hood through a duct leading to an in-house ventilation system that contains and/or neutralizes hazardous materials.

In ductless fume hoods, fans draw exhaust air through a series of filters that remove irritating substances before release back into the room. Since these filters are not 100% efficient in removing all substances, ductless fume hoods are not advised in the presence of biohazards; however, they provide a convenient, cost-effective solution for operations involving irritating but non-hazardous fumes in facilities where an in-house HVAC system cannot be accessed.

Biosafety Cabinets

Biological Safety cabinets combine design aspects of both laminar flow and fume hoods. Filtered air is directed downward onto the work surface and then travels into a plenum through openings on the front and sides of the hood. Depending on the classification of the biosafety hood, some percentage of air is recirculated through a HEPA filter while the rest is directed out of the hood through an exhaust system. Thus, biosafety cabinets offer operator, environmental and product protection.

These laboratory safety cabinets (sometimes called IV hoods or compounding hoods) are ideal when preparing sterile medications such as chemotherapeutic agents that may pose a risk to the operator.

BSCs, BSLs, and ISO Classes

When it comes to working with hazardous or potentially infectious material, protecting personnel must be the primary concern. However, offering personnel protection does not have to come at the cost of risking product integrity. Class II BSCs provide protection to both personnel and product simultaneously. They maintain an ISO class 5 clean work area for product manipulation, while ensuring that exhaust air is filtered and ducted out of the environment. Thus, a class II BSC is the ideal solution when working with moderately hazardous material and both personnel and product safety are required.

Read more about these lab hoods here regarding their biological safety rating

Don't Budge on Your Budget, Save on High-Quality ValuLine Products

Compromising on quality goods with costs can be tiring. Here at Terra, the compromise is over with our wide range of ValuLine products. From cleanrooms to glove boxes, ValuLine products come with a premium quality without sacrificing an affordable price.

Long Running FFU Motors

Terraā€™s filter fan unit motors are rated for 5 years of continuous, 24/7 operation, if the HEPA filters are consistently replaced. To accurately monitor your HEPA filterā€™s saturation levels, purchase Terraā€™s audible and visual filter replacement alarm system.

HEPA Fan Filter Unit with Integrated LED Light and Ionizer

FFU with built-in, flush-mount LED and ionizing bar provides HEPA filtered air and neutralization of static charges. Eliminates hard-to-clean, exposed light fixture and ion bar. Includes internal baffling plate and diffuser panel.

Vertical Flow of HEPA-Filtered Air Meets ISO 5 Particle Requirements

Side panels and access shield optimize unidirectional flow of HEPA-filtered air; advanced baffling technology ensures uniform face velocity to meet ISO 5 particle requirements.

WhisperFlowĀ® Cleanroom Fan Filter Units

Design features internal baffling and an aluminum diffuser to provide quiet operation along with uniform air speed for ISO-compliant laminar flow.

Tilt-Up Shield

Static-dissipative PVC tilt-up shield on the ValuLineā„¢ Vertical Laminar Flow Station enhances unidirectional air flow and protects operator against chemical splashes.

Clean and Durable Powder Coat Finish

Terraā€™s signature white powder coat finish provides a high quality, durable barrier to protect against corrosion, plus a clean and attractive aesthetic. The advanced heat-fused formulation exceeds ASTM and ISO paint standards to resist chipping, scratching, fading, and wearing.

WhisperFlow Quiet Operation Reduces Distracting Background Noise

Exposure to loud noises can lower the ability to focus on work and listen selectively, which may also lead to safety issues. Typical AC units can be annoyingly loud, measuring in the range of 70 dB (comparable to a vacuum cleaner). Terraā€™s WhisperFlow design produces far lower noise levels for a quiet environment comparable to a library. At 90 ft/min output, units measure under 50 dB from only 1 ft away (roughly 75% quieter than 70dB).

Highest Standards For Electronic Components

Terraā€™s electronic components are designed and built to the highest standards required by defense and semiconductor industries for long-term reliability and protection against damage, injuries, and electrical hazards.

Continuous Product Improvement

At Terra, we strive to develop and produce the highest quality products for our customers to improve health, safety, performance, and yields. Our product quality is enabled by high-grade manufacturing equipment and processes, 45 years of engineering and application expertise, and our commitment to continuously improve.

Long-Term Customers

Terra is committed to building long-term relationships with satisfied clients; 94% of orders each year come from repeat customers

Complete Order Transparency

Using Terraā€™s OnTrak system, our customers can view real-time production updates, receive shipment notifications and track their orders until they arrive at their facility
Popular Accessories
For a full list of accessories, select a product then click Choose Accessories on that product page.
  • Static-Neutralizing Ionizing Bar

    Airflow from the blower distributes positive and negative ions onto the surfaces below, neutralizing static charges that can lead to electro-static discharge and attract particles.
  • Lighthouse Handheld Airborne Particle Counters

    Lightouse portfolio of handheld airborne particle counters ensure accurate readings of cleanrooms and critical environments

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.