Terra Part # Price Ships in
120 V ISO 7 304 Stainless Steel 48.95" 30" 36.75" Attached 2001-65 49221 $6,313 1-3 Days 2
Only 2 left in stock
120 V ISO 7 304 Stainless Steel 72.95" 30" 36.75" Attached 2001-66 49223 $7,857 1-3 Days 3
Only 1 left in stock
120 V ISO 7 304 Stainless Steel 96.95" 30" 36.75" Attached 2001-67A 80980 $9,045 1-3 Days 4
Quick Ship+ Available In stock soon
120 V ISO 7 Powder-Coated Steel 48.95" 30" 36.75" Attached 2001-68A 80981 $4,452 1-3 Days 5
Quick Ship+ Available Only 3 left in stock
120 V ISO 7 Powder-Coated Steel 72.95" 30" 36.75" Attached 2001-69 49229 $5,070 1-3 Days 6
12 in stock
120 V ISO 7 Powder-Coated Steel 96.95" 30" 36.75" Attached 2001-70 49231 $6,079 1-3 Days 7
12 in stock
240 V ISO 7 Powder-Coated Steel 48.95" 30" 36.75" Optional 2001-68B-220 84721 $4,484 4-6 Days 8
240 V ISO 7 Powder-Coated Steel 72.65" 30" 36.75" Attached 2001-69A-220 80990 $5,070 1-3 Days 9
Only 3 left in stock
Voltage
Certified ISO Grade Design
Frame Material
Inside Width
Inside Depth
Inside Height
Table Configuration
Item ordered before. Click on bagde to see the order.

Up to 30-day trial periods, free return shipping and on-site training available for qualified equipment.

Request demo from your product specialist or add note to your order or quote request.

Some ship in:
Usually Ships in:
Free shipping in contiguous USA
Custom-configured product. Contact Terra by phone, chat or email for a project-specific quote.
Custom-configured product. Contact Terra by phone, chat or email for a project-specific quote.
Select a product line for product summary
Product Details
Product Details
  • Available ISO Ratings: ISO 7, ISO 8
  • This economical, free-standing workstation provides a particle-free environment for contamination-sensitive work
  • Transparent, static-dissipative PVC panels prevent particles from clinging to the wall surfaces and are chemical resistant
  • The tilt-up sash (also static-dissipative PVC) guides the airflow over the work surface and features two sets of hinges for different access needs
  • HEPA-filtered blower module includes a backpressure gauge, internal baffling plates and an anodized aluminum diffuser panel that ensures uniform air speed across the filter face
  • A fluorescent light fixture is mounted behind the sash, minimizing glare
  • Air speed is controlled by a dial on the front of the workstation, next to the power switches for the blower and light fixture
  • Powder-coated steel stand and stainless steel work surface are built into the workstation
  • Includes a GFCI duplex power outlet inside the work area

Available ISO Ratings: ISO 7, ISO 8

UL File Number: E326560

UL Standard: UL 507

Unit of Measure: of 1

Marks & Listings: CE, UL, ULC

ValuLine™ Vertical Laminar Flow Workstations
Standard Features
  • A Fluorescent light standard
    Fluorescent light standard, UV sterilization bulbs available
  • B SDPVC Side Panels
    Side panels, made of static-dissipative PVC, ensure effective laminar flow
  • C Fan Filter Units
    Integrated HEPA fan/filter modules, with back pressure gauge, provides a laminar flow of clean air
  • D Stainless Steel Work Surface
    Stainless Steel Work Surface
  • E Static-dissipative PVC tilt-up sash
    Static-dissipative PVC tilt-up sash
  • G Status Indicator
    Status Indicator

Not Shown: Nylon Levelers - Steel-reinforced nylon levelers resist most chemicals

ValuLine™ Vertical Laminar Flow Workstations

  • Terra Universal WhisperFlow Laminar Flow Hoods Terra Universal WhisperFlow Laminar Flow Hoods
  • Laminar Flow Hood Smoke Test
  • High-Clearance, Wide-Access Vertical Laminar Flow Hoods ValuLine™ Vertical Laminar Flow Stations
  • Vertical Laminar Flow Tilt-Up Shield Tilt-Up Shield
  • Powder-Coated Steel Laminar Flow Hood ValuLine™ Vertical Laminar Flow Station
Terra Universal WhisperFlow Laminar Flow Hoods
Features & Benefits

Features and Benefits

Learn More: Laminar Flow and Fume Hoods

Laminar Flow and Fume Hoods FAQs

Laboratory hoods serve a number of critical purposes in the lab environment.

Product protection from particulate contaminants in the lab environment, including microbes

Such hoods, often called laminar flow workstations or clean benches, use a flow of HEPA-filtered air to prevent influx of viable and non-viable particles into the enclosure and to sweep away any contaminants generated by the work process.

Protection of personnel and lab environment from substances generated inside the enclosure

For fume containment, laboratory fume hoods use a ducted ventilation system that maintains negative pressure. Where ducting is impractical, ductless hoods are also available for removal of non-hazardous contaminants (fumes or particles), using either HEPA or activated carbon filters.

Protection of product, operator and environment

Biological safety cabinets combine aspects of both hood types: a laminar flow of micro-filtered air and negative-pressure containment of bio-hazard fumes.

Laminar Flow Hoods

Laminar flow hoods (also called laminar flow clean benches) force air through a HEPA or ULPA filter to create a clean work area free of nearly all contaminating particulates, including bacteria, mold spores and many viruses. These hoods use a vertical or horizontal airflow design. Both provide excellent protection of products from particulates and cross-contamination, but do not protect the operator or environment.

So why choose one over the other? Vertical laminar flow hoods (VLF Hoods) require less floor space, but more overhead clearance. In addition, a sash at the front of the VLF hood provides a barrier between air exiting the hood and the operator’s face. VLF hoods create turbulent air flow when air strikes the work surface, requiring sterile work to be performed above the work surface.

HLF hoods minimize air turbulence (and particle backflow) on the work surface except where equipment disrupts the horizontal airflow. However, they direct the airflow directly at the operator’s face and require more depth to accommodate placement of the fan filter unit at the rear of the hood.

Read more about the differences between horizontal and vertical laminar flow hoods

Fume Exhaust Hoods

Laboratory fume hoods draw air from the environment through the opening of the hood, allowing environmental contaminants into the work area. Thus, lab fume hoods do not offer a sterile environment or product protection. Instead, chemical fume hoods are designed to protect the operator from dangerous or irritating fumes and powders generated from work performed inside the hood.

In ducted fume hoods and canopy fume hoods, air passes out of the hood through a duct leading to an in-house ventilation system that contains and/or neutralizes hazardous materials.

In ductless fume hoods, fans draw exhaust air through a series of filters that remove irritating substances before release back into the room. Since these filters are not 100% efficient in removing all substances, ductless fume hoods are not advised in the presence of biohazards; however, they provide a convenient, cost-effective solution for operations involving irritating but non-hazardous fumes in facilities where an in-house HVAC system cannot be accessed.

Biosafety Cabinets

Biological Safety cabinets combine design aspects of both laminar flow and fume hoods. Filtered air is directed downward onto the work surface and then travels into a plenum through openings on the front and sides of the hood. Depending on the classification of the biosafety hood, some percentage of air is recirculated through a HEPA filter while the rest is directed out of the hood through an exhaust system. Thus, biosafety cabinets offer operator, environmental and product protection.

These laboratory safety cabinets (sometimes called IV hoods or compounding hoods) are ideal when preparing sterile medications such as chemotherapeutic agents that may pose a risk to the operator.

BSCs, BSLs, and ISO Classes

When it comes to working with hazardous or potentially infectious material, protecting personnel must be the primary concern. However, offering personnel protection does not have to come at the cost of risking product integrity. Class II BSCs provide protection to both personnel and product simultaneously. They maintain an ISO class 5 clean work area for product manipulation, while ensuring that exhaust air is filtered and ducted out of the environment. Thus, a class II BSC is the ideal solution when working with moderately hazardous material and both personnel and product safety are required.

Read more about these lab hoods here regarding their biological safety rating

Long Running FFU Motors

Terra’s filter fan unit motors are rated for 5 years of continuous, 24/7 operation, if the HEPA filters are consistently replaced. To accurately monitor your HEPA filter’s saturation levels, purchase Terra’s audible and visual filter replacement alarm system.

HEPA Fan Filter Unit with Integrated LED Light and Ionizer

FFU with built-in, flush-mount LED and ionizing bar provides HEPA filtered air and neutralization of static charges. Eliminates hard-to-clean, exposed light fixture and ion bar. Includes internal baffling plate and diffuser panel.

Vertical Flow of HEPA-Filtered Air Meets ISO 5 Particle Requirements

Side panels and access shield optimize unidirectional flow of HEPA-filtered air; advanced baffling technology ensures uniform face velocity to meet ISO 5 particle requirements.

WhisperFlow® Cleanroom Fan Filter Units

Design features internal baffling and an aluminum diffuser to provide quiet operation along with uniform air speed for ISO-compliant laminar flow.

Tilt-Up Shield

Static-dissipative PVC tilt-up shield on the ValuLine™ Vertical Laminar Flow Station enhances unidirectional air flow and protects operator against chemical splashes.

Clean and Durable Powder Coat Finish

Terra’s signature white powder coat finish provides a high quality, durable barrier to protect against corrosion, plus a clean and attractive aesthetic. The advanced heat-fused formulation exceeds ASTM and ISO paint standards to resist chipping, scratching, fading, and wearing.

WhisperFlow Quiet Operation Reduces Distracting Background Noise

Exposure to loud noises can lower the ability to focus on work and listen selectively, which may also lead to safety issues. Typical AC units can be annoyingly loud, measuring in the range of 70 dB (comparable to a vacuum cleaner). Terra’s WhisperFlow design produces far lower noise levels for a quiet environment comparable to a library. At 90 ft/min output, units measure under 50 dB from only 1 ft away (roughly 75% quieter than 70dB).

Highest Standards For Electronic Components

Terra’s electronic components are designed and built to the highest standards required by defense and semiconductor industries for long-term reliability and protection against damage, injuries, and electrical hazards.

Continuous Product Improvement

At Terra, we strive to develop and produce the highest quality products for our customers to improve health, safety, performance, and yields. Our product quality is enabled by high-grade manufacturing equipment and processes, 45 years of engineering and application expertise, and our commitment to continuously improve.

Long-Term Customers

Terra is committed to building long-term relationships with satisfied clients; 94% of orders each year come from repeat customers

Complete Order Transparency

Using Terra’s OnTrak system, our customers can view real-time production updates, receive shipment notifications and track their orders until they arrive at their facility

Catalog of CE-Marked Products

Terra offers over 1,700 CE-marked products configured for international voltage requirements

Don't Budge on Your Budget, Save on High-Quality ValuLine Products

Compromising on quality goods with costs can be tiring. Here at Terra, the compromise is over with our wide range of ValuLine products. From cleanrooms to glove boxes, ValuLine products come with a premium quality without sacrificing an affordable price.
Available Accessories
Popular Accessories
For a full list of accessories, select a product then click Choose Accessories on that product page.
  • Static-Neutralizing Ionizing Bar

    Airflow from the blower distributes positive and negative ions onto the surfaces below, neutralizing static charges that can lead to electro-static discharge and attract particles.
  • Lighthouse Handheld Airborne Particle Counters

    Lightouse portfolio of handheld airborne particle counters ensure accurate readings of cleanrooms and critical environments
  • Replacement Filters

    Purchase replacement filters ahead of time to prevent costly operational interruptions and avoid damage to fan blowers caused by excessive backpressure from long overdue filter replacements.
Products similar to this one
Other products you may find relevant
Buy Accessories
Manuals & Resources

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.