Worldwide Pricing and Secure Global Shipping Available!
1675-57-60
Terra Part # 1675-57-60
$6,215
Accessories related to Terra Part # 1675-57-60
81431
Universal Containment Hood; Laminar Flow, Polypropylene, 60" W x 30" D x 42" H, 120 V
Usually ships in 10-12 business days

Want it faster ? Read about FasTrak

Product Details
  • Available Certified ISO Grade Designs: ISO 6, ISO 7, ISO 8
  • Ideal for biological sample treatment, solvent cleaning, or other processes that require protection from non-hazardous dust and fumes
  • Select 99.99% efficient HEPA or 99.999% efficient ULPA fan/filter unit to provide a vertical laminar flow of particle-free air inside the work area
  • Perforated work surface contains spills and directs air to an in-house exhaust duct (can be customized to provide solid surface)
  • Low-profile design fits on standard benches and requires no rear access or clearance
  • Polypropylene models resist wide range of aggressive chemicals, including acids
  • Baffle adjustments allows some control over speed and direction of exhausted air
  • Tilt-up static-dissipative PVC sash resists wide range of chemicals
  • Unless otherwise specified, unit price includes packaging costs.
  • For 220V models please contact a sales associate.

Model: Exhaust Fume

Manufactured by: Terra Universal

Width: 60"

Sash Opening: 15"

Work Area Dimensions: 58" W x 28" D x 28" H

Inside Height: 28"

Inside Depth: 28"

Inside Width: 58"

Frame Material: Polypropylene

Hood Design: Benchtop

ISO Rated Air Cleanliness: ISO 5

Unit of Measure: EA

Marks & Listings: UL, ULC

Electrical Specifications: 120 V, 3.7 A, 444 W, 1 Ph, 60 Hz

Weight, Product: 230 lb

Dimensions, Product: 60" W x 30" D x 42" H

Weight, Shipping: 360 lb

Dimensions, Shipping: 66.5" W x 36.5" D x 49.5" H

Package Type: Palletized

Universal™ Containment Hoods

  • ISO 5 BioSafe Flowhood Watch Terra's BioSafe® Universal Benchtop Hoods Video
  • Vibration isolation stand adjustable video Watch Terra's Vibration Isolation Stand Video
  • Adjustable isolation stand Vibration Isolation Stand
  • ErgoHeight® workstations Watch Terra's ErgoHeight® Workstations Video
ISO 5 BioSafe Flowhood
Vibration isolation stand adjustable video
Adjustable isolation stand
ErgoHeight® workstations

Features and Benefits

Learn More: Laminar Flow and Fume Hoods

Laminar Flow and Fume Hoods FAQs

Laboratory hoods serve a number of critical purposes in the lab environment.

Product protection from particulate contaminants in the lab environment, including microbes

Such hoods, often called laminar flow workstations or clean benches, use a flow of HEPA-filtered air to prevent influx of viable and non-viable particles into the enclosure and to sweep away any contaminants generated by the work process.

Protection of personnel and lab environment from substances generated inside the enclosure

For fume containment, laboratory fume hoods use a ducted ventilation system that maintains negative pressure. Where ducting is impractical, ductless hoods are also available for removal of non-hazardous contaminants (fumes or particles), using either HEPA or activated carbon filters.

Protection of product, operator and environment

Biological safety cabinets combine aspects of both hood types: a laminar flow of micro-filtered air and negative-pressure containment of bio-hazard fumes.

Laminar Flow Hoods

Laminar flow hoods (also called laminar flow clean benches) force air through a HEPA or ULPA filter to create a clean work area free of nearly all contaminating particulates, including bacteria, mold spores and many viruses. These hoods use a vertical or horizontal airflow design. Both provide excellent protection of products from particulates and cross-contamination, but do not protect the operator or environment.

So why choose one over the other? Vertical laminar flow hoods (VLF Hoods) require less floor space, but more overhead clearance. In addition, a sash at the front of the VLF hood provides a barrier between air exiting the hood and the operator’s face. VLF hoods create turbulent air flow when air strikes the work surface, requiring sterile work to be performed above the work surface.

HLF hoods minimize air turbulence (and particle backflow) on the work surface except where equipment disrupts the horizontal airflow. However, they direct the airflow directly at the operator’s face and require more depth to accommodate placement of the fan filter unit at the rear of the hood.

Read more about the differences between horizontal and vertical laminar flow hoods

Fume Exhaust Hoods

Laboratory fume hoods draw air from the environment through the opening of the hood, allowing environmental contaminants into the work area. Thus, lab fume hoods do not offer a sterile environment or product protection. Instead, chemical fume hoods are designed to protect the operator from dangerous or irritating fumes and powders generated from work performed inside the hood.

In ducted fume hoods and canopy fume hoods, air passes out of the hood through a duct leading to an in-house ventilation system that contains and/or neutralizes hazardous materials.

In ductless fume hoods, fans draw exhaust air through a series of filters that remove irritating substances before release back into the room. Since these filters are not 100% efficient in removing all substances, ductless fume hoods are not advised in the presence of biohazards; however, they provide a convenient, cost-effective solution for operations involving irritating but non-hazardous fumes in facilities where an in-house HVAC system cannot be accessed.

Biosafety Cabinets

Biological Safety cabinets combine design aspects of both laminar flow and fume hoods. Filtered air is directed downward onto the work surface and then travels into a plenum through openings on the front and sides of the hood. Depending on the classification of the biosafety hood, some percentage of air is recirculated through a HEPA filter while the rest is directed out of the hood through an exhaust system. Thus, biosafety cabinets offer operator, environmental and product protection.

These laboratory safety cabinets (sometimes called IV hoods or compounding hoods) are ideal when preparing sterile medications such as chemotherapeutic agents that may pose a risk to the operator.

BSCs, BSLs, and ISO Classes

When it comes to working with hazardous or potentially infectious material, protecting personnel must be the primary concern. However, offering personnel protection does not have to come at the cost of risking product integrity. Class II BSCs provide protection to both personnel and product simultaneously. They maintain an ISO class 5 clean work area for product manipulation, while ensuring that exhaust air is filtered and ducted out of the environment. Thus, a class II BSC is the ideal solution when working with moderately hazardous material and both personnel and product safety are required.

Read more about these lab hoods here regarding their biological safety rating

Removable Perforated Polypropylene Tray

Perforated polypropylene tray minimizes the impact of spills and resists chemicals. Harmful substances pass underneath while the tray slides out for easy clean-up.

Adjustable Air Baffles

Adjustable baffles allow some user control over direction and speed of airflow for tailored particle and fume containment across the work surface.

Terra's QuickBuild Program

Build your system using in-stock components and accessories. We’ll assemble your system, package and ship your order in 6 business days.

Products Tailored to Your Cleanroom Environment

Provide Terra with your desired ISO Grade design. We will tailor the product to meet your criteria and certify it with a report appended to your invoice. Certificate includes all the necessary information to streamline audits and facility compliance.
Popular Accessories
For a full list of accessories, select a product then click Choose Accessories on that product page.
  • Vibration Isolation Stand

    Width and height adjustable stand supports the user on vibration sensitive applications by isolating their equipment from the work surface
  • Lighthouse Handheld Airborne Particle Counters

    Lightouse portfolio of handheld airborne particle counters ensure accurate readings of cleanrooms and critical environments
  • Vapor-Sealed Fluorescent Illuminator

    This fluorescent light fixture is enclosed in a vapor-sealed, static-dissipative PVC housing to protect the light source from dust, dirt, and vapors. The housing extends the useful life of the light fixture and provides an easy-to-clean surface.
  • Vibration-Isolated Table

    Works surface and stand pair provide vibration-isolated solution for Biosafe Universal Hoods
  • Ionizing Bar with Installation Kit

    Ionizer emits equal quantities of positive and negative ions to neutralize static charges within the work area, system requires no calibration or adjustments.
  • UV Germicidal Lamp

    The V-Ray germicidal UV lamp is installed within a Terra hood to inhibit microbial growth on the work surface
  • Benchtop ISO 5 Vertical Laminar Flow Hood with Automatic Height Adjusting Table

    Vertical laminar flow hoods provide a HEPA-filtered work area for protection from particle contaminants. Benchtop laminar flow hoods can easily mount to an automatic height adjusting table (28"-43"H). Perfect for workstations with heavy or fragile equipment.
Buy Accessories

On a tight schedule? Choose FasTrak 24/7 Priority Service to help meet your critical schedule for Terra-manufactured products, either before or after your order is placed.*

  • FasTrak 24/7 provides a 24/7 commitment to meet the shipping date YOU specify, regardless of quoted lead times.
  • FasTrak 24/7 assigns a dedicated production team plus a dedicated senior expeditor working three shifts to meet your delivery specification.
  • FasTrak 24/7 guarantees* to meet the agreed-to specified ship date.

Call for pricing. FasTrak service fees cover costs of additional services only, without additional profit.

 * Terra's FasTrak services limited guarantee: to ship on the ESD or date specified OR to refund up to 100% of FasTrak charges. This guarantee covers no direct, special, consequential or other damages and is strictly limited to up to 100% of the amount paid for FasTrak service. When a specified ship date is missed due to factors outside Terra's control (vendor performance, deliveries by shipping companies, etc.) and random factors such as accidents, the credit of up to 100% of the FasTrak 24/7 may not apply. FasTrak service requested after order placement will be quoted and accepted based on available time remaining before required ship date.