BioSafe® Cleanroom Panels
|
 |
| Stainless steel BioSafe® panels, configured for pharmaceutical sample preparation and vialing rooms. |
|
These freestanding, double-wall structures meet critical requirements for flexible configurations, rapid delivery, and clean operation. |
|
Pre-Engineered, Modular Designs for Accelerated Delivery
|
| Engineered for ease of installation and cleaning, BioSafe® Cleanroom panels come in standard 4-foot (1219 mm) widths and heights ranging from 7 to 10 feet (2134 mm to 3048 mm). Their modular design lets you configure a custom cleanroom using pre-engineered components, many of which are inventoried at Terra’s Fullerton, California manufacturing facility. |
|
Terra technicians factory-assemble and test each BioSafe®Cleanroom to ensure it meets performance requirements prior to packaging. Panels and other components are labeled before crating to simplify installation, which typically requires no special contracting or permitting (on-site installation and testing services available).
Whether your requirements call for a single room or a multi-suite facility, your BioSafe® Cleanroom is operational in a fraction of the time and at a fraction of the cost associated with conventional cleanrooms.
|
|
|
 |
Radius corners on all corner panels
simplify cleaning and sterilization |
Double-Wall Structure Enhances Aseptic Processing
The two-piece design of BioSafe® steel panels provides the benefits of standard bio-cleanroom wall construction in a completely modular panel.
BioSafe® panels support aseptic operations. All panel materials—powder-coated steel, 304/316 stainless steel, and tempered safety glass—stand up to frequent cleaning with standard disinfectants, including DI water/alcohol solutions. Panel seams are caulked with FDA-approved silicone sealant to eliminate cracks that could harbor germs and other contaminants. Radius bends on corner panels further facilitate cleaning by providing smooth surfaces that are easy to wipe down. (See cleaning protocol for additional information.)
|
 |
|
 |
| Tempered safety glass panels, securely positioned inside 30” H (762 mm) steel supports, provide easy-clean, aseptic surfaces while enhancing visibility and opening up the work environment |
|
Double-wall panel design accommodates utilities and insulation |
|
|
 |
| Adjustable air return registers simplify air pressure balancing |
 |
| Available with quick-connect gas and vacuum fitting, flush-mount electrical and data lines |
Each panel features a snap-off cover for easy access to internal components:
- Electrical and data lines: installation of all wiring inside the panel allows flush-mount outlets and data ports.
- Air returns: internal air channels eliminate the need for vertical ducting of return air inside the cleanroom (more on HVAC and air control system).
- Insulation: insulation mounted inside panels not only reduces energy costs in air conditioned BioSafe® Cleanrooms, but also increases rigidity of the double-panel structure (eliminating “oil can” deflection) and reduces noise and vibration.
- Vacuum, DI water and gas utilities: quick-connect fittings allow convenient access to service lines plumbed inside the panels.
 |
| Double-wall BioSafe® Panels accommodate electrical and gas utilities, insulation, air returns |
|
|
 |
| Windows, mounted in steel supports, are available in four easy-clean materials |
Window and Door Materials for Every Requirement
Panels are easily modified to accommodate many window sizes (standard dimensions: 36”W x 48”H, 914 mm x 1219 mm). Available in single- or double-glazed configurations, windows mount in rugged steel casings to ensure safe support.
Access doors are available in single and double-door designs. Specify swing direction (standard mounting: door swings away from clean room).
|
|
|
|
| Standard stainless steel door frame with static-dissipative PVC or tempered glass panes (left); heavy-duty tempered safety glass door (right) |
|
|
| BioSafe® |
Cleanroom |
Antechamber |
Internal
Wall |
| Panel/Grid
Material |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
Cat.
# |
$/Each |
| Powder-Coated
CR Steel |
6600-30 |
Login
|
6600-35 |
Login
|
6600-40 |
Login
|
| 304
Stainless Steel |
6600-31 |
Login
|
6600-36 |
Login
|
6600-41 |
Login
|
| 316
Stainless Steel |
6600-32 |
Login
|
6600-37 |
Login
|
6600-42 |
Login
|
| Windows
(specify quantity, size, location) |
| Material |
Cat.
# |
$/Each |
| Tempered
Glass |
6600-45 |
Login
|
| Fire-Rated
Glass |
6600-46 |
Login
|
| Static-Dissipative
PVC |
6600-47 |
Login
|
| Polycarbonate |
6600-48 |
Login
|
| Access Doors |
| Frame Type |
Door Panel Material |
Cat. # |
$/Each |
| 304 SS Swing |
Tempered Glass |
6602-15 |
Login
|
| 304 SS Swing |
Static-Dissipative PVC |
6602-16 |
Login
|
| 316 SS Swing |
Tempered Glass |
6602-17 |
Login
|
| 316 SS Swing |
Static-Dissipative PVC |
6602-18 |
Login
|
| Aluminum Swing |
Acrylic* |
6711-08 |
Login
|
| Aluminum Swing |
Static-Dissipative PVC |
6711-07 |
Login
|
| * Acrylic is damaged by alcohol and other cleaning agents. |
|
|